BM Series - 6 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

Catalogue excerpts

Micro Analytical Balances Built-in Fanless Ionizer! ISO 9000 CERTIFIED ...Clearly a Better Value http://www.aa

 Open the catalogue to page 1

How to Eliminate the Greatest Enemy of Precision Weighing Static electricity, while often overlooked, can be a fatal source of error in precise weight measurements. With the BM Series, A&D seek in various ways to help you perform sometimes-tricky analytical weighing with simplicity and accuracy, including the elimination of static electricity. The world of micro grams (µg) is now accessible to all researchers! Errors due to static electricity An electrostatically charged object induces the opposite charge in nearby objects. The attraction between the two charges causes an inaccurate value. Error...

 Open the catalogue to page 2

Weighing Chamber |ust press the ION key to switch mark blinks on the display. The internal mass of the BM Series allows you to perform calibration quickly and correctly even if you are not skilled at calibrating balances using external masses. The balance can self-calibrate automatically when it The accuracy of your balance is assured with detects a change in ambient temperature. one key press. The balance automatically adjusts its response characteristics (FAST, MID, or SLOW) by analyzing the influence of drafts or vibrations on the stability of the display value. (Manual adjustment is also possible.) The...

 Open the catalogue to page 3

To block drafts, A&D adopted a double-ring structure around the weighing pan and two vertical shields under the separation plate. This offers more space and easier operation than conventional 1 ug balances with a secondary breeze break in the chamber. A large flask or cylinder Double-ring structure The contrast of black and white display provides excellent readability. It is possible to slide a door open using the handle on the opposite side. Effective use of both hands lets you perform weighing more efficiently. completely closed.) The balance displays the temperature, humidity, and atmospheric...

 Open the catalogue to page 4

The balance can store up to 200 sets of weighing data (100 sets with date & time) or 50 sets of calibration history data. In accordance with the Good Laboratory Practice (GLP), the balance can output the balance manufacturer, model, serial number, ID number, date, time, calibration mass used, space for Two different devices (e.g. PC and remote controller) can be connected simultaneously to a balance. An external key plug for the optional foot switch (AX-SW128) is also provided as standard. Foot switch iv Weighing data transfer from You can send commands for controlling and acquiring data from...

 Open the catalogue to page 5

Weighing capacity Linearity Stabilization time (when set to FAST) Repeatability (standard deviation) Minimum weighing value Approx. 10 secs / 8 secs when automatic self calibration is not used) Operating temperature 5 times / second or 10 times / second Display refresh rate g, mg, oz, ozt, ct, mom, dwt, GN, tael, tola, PC (counting mode), % (percent mode), Specific gravity Display mode Counting mode Minimum unit mass Percent mode Minimum 100% reference mass 0.01%, 0.1%, 1% (depends on the reference mass stored) Minimum 100% display Standard interface Internal calibration Motor-driven internal...

 Open the catalogue to page 6

All A&D Company, Limited catalogues and technical brochures

  1. UM Series

    6 Pages

    En
  2. GR Series

    4 Pages

    En
  3. GH Series

    4 Pages

    En
  4. MPA Series

    4 Pages

    En
  5. TM-2915

    2 Pages

    En
  6. UA-651

    2 Pages

    En
  7. UA-767F

    2 Pages

    En
  8. AD-6121A

    1 Pages

    En
  9. UA-1000 Series

    2 Pages

    En

Archived catalogues