video corpo

Denta Hybrid owner's manual - 11 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

Denta Hybrid Owner´s Manual

 Open the catalogue to page 1

Note: Do not use sharp objects when unpacking the luminaire! 1. Unpacking Your Denta Hybrid Open the packaging carefully without using any sharp objects! The packaging includes: • Wire arrangements for attaching the luminaire to the cieling (4 pcs) • The Denta Hybrid luminaire

 Open the catalogue to page 2

1/3 PARALELL POSITION The eyes of the patient should be in line with 1/3rd of the luminaire. CROSSWISE POSITION The eyes of the patient should be in line with the top lightsource! POSITION of the patient in line with he luminaire. CROSSWISE POSITION The eyes of the patient should be in line with the top lightsource! 2. Positioning your Denta Hybrid positions: • Parallel position - the eyes of the patient should be in line with 1/3rd of the luminaire. • Crosswise position - the eyes of the patient should be in line with the top lightsource. Note: The recommended height of the luminaire is to be...

 Open the catalogue to page 3

3. Preparing the mounting of your Denta Hybrid After unpacking the luminaire use the packaging as a guide for marking the attachment points in the ceiling. • On the outside of the cardboard, there are four attachment points marked out. Punch a hole in these four points with a screwdriver or similar • Hold the cardboard lid where you want to position the luminaire in the ceiling and mark the four points where you would like the wires to be attached and drill holes accordingly

 Open the catalogue to page 4

Aluminum nipple 4. Mounting your Denta Hybrid in the ceiling There are two options of mounting kits enclosed with your luminaire. Use the kit suitable to your needs and preferences.

 Open the catalogue to page 5

5. Operating your Denta Hybrid The luminaire is operated by a pulling string/cord or, on special requests, by a wall switch. Instructions to operate the indirect light and dimmer function: • Switching the lamp on/off: short pull (<0,5 second) • Dimming: Long pull (>0,5 second), the dimming direction is changed with each pull. • To reset: pull and hold the string for approximately 30 seconds The last dimmer setting is remembered until the next time the luminaire is switched on. Caution! Ensure you fade out the lamp when working with lightcuring materials.

 Open the catalogue to page 6

6. Operating your Denta Hybrid with LED (optional) The LED lighting in the centre of the unit allows colours to change shade at a speed selected by you with the accompanying Infrared remote control. You can easily choose between different fixed colours, dim the light or select a light programme. • 4 buttons marked R, G, B and W (red, green, blue and white) for switching the named colours on/off and dimming the same. They can also be mixed to a new shade of your preference. • 12 buttons with pre-set colours • 4 buttons (white) for dimming the currently set colour at 100%, 75%, 50% and 25% • 1 button...

 Open the catalogue to page 7

LIGHTING SYSTEMS 7. Exchange of fluorescent light tubes

 Open the catalogue to page 8

Image of recommended light conditions for dentists

 Open the catalogue to page 9

On-line support http://d-tec.se/support • Owner’s manual • Användarmanual • Bedienungsanleitung • Mode d’emploi

 Open the catalogue to page 10

Facts: Denta Hybrid • Environmentally friendly and energy-saving • Including indirect light • Optional dimmer • Optional flat-screen bracket • Optional LED lighting with rotating colours • High intensity of illumination 4 000 lux/1,2 m • Size 1 560 x 780 x 55 mm • Weight 22 kgs

 Open the catalogue to page 11

All D-TEC catalogues and technical brochures

  1. Halo

    3 Pages

    En
  2. Product catalogue

    11 Pages

    En

Archived catalogues

  1. Clair

    3 Pages

    En