• Products
  • Catalogues
  • News & Trends
  • Exhibitions

Round flow cassette ECPEN13-110 - 16 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

Heating & Cooling Round flow cassette »» High COP cassette ensures top performance »» 360° air discharge »» Auto-cleaning cassette »» Even more comfort by avoiding draught »» Cold feet become history »» Flexibility to suit any room lay-out www.daik in.eu Replacement technology

 Open the catalogue to page 1

Setting the standard for efficiency and comfort Whether we’re talking about a shop, office or small public area, getting the heating and cooling right is a performance imperative, and for optimal performance you need optimal comfort in terms of temperature, humidity and air flow. To deliver this, you need the Daikin round flow cassette as part of the solution.

 Open the catalogue to page 3

To achieve optimal comfort you need the perfect distribution of air at the right temperature. This distribution must reach all parts of the room with no dead areas, but, at the same time, with no draughts or cold spots. This is where the 360° air flow discharge pattern of the round flow cassette, combined with its optional sensors and special features, really delivers. • The round flow cassette delivers air through four individually controllable flaps to ensure that the air reaches all parts of the room. • The optional presence sensor detects when people are in the room and directs the air flow...

 Open the catalogue to page 4

Top efficiency As you would expect from Daikin, the round flow cassette is one of the top performing cassettes on the market. With a high COP and an A++ energy rating for both heating and cooling, it has two important features that help deliver superior efficiency. Standard auto-cleaning feature Keeping the filters clean is a critical contributory factor to high efficiency and we have incorporated a fully automatic daily cleaning feature within the standard panel to ensure this is done without you having to remember. Compared to standard solutions, this has been found to reduce energy consumption...

 Open the catalogue to page 5

Flexible installation To provide you with as much flexibility as possible in installing the system or changing the layout of your rooms, we have incorporated a number of set-up features to ensure that the Cool or heat up small to large applications with a single outdoor unit cassette delivers optimally no matter what interior design A single Daikin outdoor unit can power up to nine cassettes conditions occur. which can be fitted in a variety of combinations. Most rooms will use a single, individually-controlled cassette but large or Closable flaps facilitate the re-design of your layout Each of...

 Open the catalogue to page 6

Total control Wired remote control BRC1E52A/B (optional) Daikin’s enhanced wired controller with its advanced functionality gives you total control over all the functions and settings of the round flow cassette thus enabling you to select optimal comfort settings, establish the highest levels of efficiency and obtain the lowest operating costs. It even displays kWh usage by day, month and year allowing you monitor your energy consumption and so control costs. The controller has three programmable schedules - for example: ›› winter for optimal heating ›› summer for optimal cooling ›› a spring/autumn...

 Open the catalogue to page 7

Home leave operation Auto-cleaning panel Draught prevention Whisper quiet Auto coolingheating changeover Centralised control Drain pump kit (standard) twin/triple/ double twin application (FCQ(H)G) Multi model application (FCQG) Dry Ceiling soiling Vertical auto programme prevention swing VRV for residential application (FCQG) Multi tenant (FXFQ) Weekly timer Infrared remote control Wired remote control Replacement technology Specifications Fully integrated solutions for medium to large commercial environments connecting up to 64 indoor units to a single system, all individually controlled. •...

 Open the catalogue to page 9

Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Seasonal efficiency (according to EN14825) Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight Decoration panel Fan - Air flow rate Sound power level Sound pressure level Piping connections Power supply FCQHG71F Min./Nom./Max. Min./Nom./Max. Cooling Energy label Pdesign SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption EER COP Annual energy consumption Energy label Cooling/Heating Colour HeightxWidthxDepth Unit Unit...

 Open the catalogue to page 10

Heating & Cooling INDOOR UNIT Cooling capacity Min./Nom./Max. Heating capacity Min./Nom./Max. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel 1 Model Decoration panel 2 Colour Decoration panel 3 Dimensions HeightxWidthxDepth Weight Fan - Air...

 Open the catalogue to page 11

Heating & Cooling INDOOR UNIT Cooling capacity Heating capacity Seasonal efficiency (according to EN14825) Nominal efficiency (cooling at 35°/27° nominal load, heating at 7°/20° nominal load) Casing Dimensions Weight Decoration panel Fan - Air flow rate Sound power level Sound pressure level Piping connections Power supply FCQG71F Min./Nom./Max. Min./Nom./Max. Cooling Energy label Pdesign SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption EER COP Annual energy consumption Energy label Cooling/Heating Colour HeightxWidthxDepth Unit Unit...

 Open the catalogue to page 12

Heating & Cooling INDOOR UNIT Cooling capacity Min./Nom./Max. Heating capacity Min./Nom./Max. Seasonal efficiency Cooling Energy label (according to Pdesign EN14825) SEER Annual energy consumption Heating Energy label (Average Pdesign climate) SCOP Annual energy consumption Nominal efficiency EER (cooling at 35°/27° COP nominal load, heating Annual energy consumption at 7°/20° nominal load) Energy label Cooling/Heating Casing Colour HeightxWidthxDepth Dimensions Unit Weight Unit Decoration panel Model Colour HeightxWidthxDepth Dimensions Weight Fan - Air flow rate Cooling High/Nom./Low Heating...

 Open the catalogue to page 13

All Daikin Europe catalogues and technical brochures

  1. Wall mounted units

    24 Pages

    En
  2. EWAD-C Family

    6 Pages

    En
  3. EWAD-C-PS/PL

    2 Pages

    En
  4. Flexi type unit

    2 Pages

    En
  5. EKHVMRD-AB

    1 Pages

    En
  6. EWAD~C

    6 Pages

    En
  7. VRV Catalogue

    186 Pages

    En
  8. FTXG-JA

    24 Pages

    En