TEB500 series bioreactor Description The TEB500 bioreactor series has been designed to facilitate the construction and manipulation of flow circuits. Thanks to its top double door closing system, the TEB500 allows accessing to the whole volume of the inner chamber, improving the access to the peristaltic pumping systems located at the rear wall of the chamber. It counts on two independent peristaltic pumping systems, which are equipped with multichannel eight-roller four cassettes pumpheads for multiple simultaneous pumping (eight channels in total). The TEB500 series is equipped with CO2 and O2 controls in its standard version and allows the user to: Control the culture media flow rate Regulate the inner temperature Regulate CO2 and O2 concentrations The TEB500 has network capabilities which allow checking the status of the equipment remotely, as well as to access the data logging system of the most relevant culture data. Applications The fully integrated configuration of the TEB500 is able to substitute a large number of equipment frequently used for cell culture in Tissue Engineering, like a CO 2 incubators, peristaltic pumps and heaters, since it integrates all their capabilities, allowing a wide variety of experimental set-ups including: Multiple simultaneous experiments, Controlled flow profiles for cell stimulation experiments or Experiments under hypoxic conditions.

 Open the catalogue to page 1

TEB500 flow bioreactor (1/2) Temperature control Temperature range Service pressure Recuperation (up to 90% of preset value) O2 control (optional) Range Service pressure Pumping system Number of pumps Two independent subsystems with electric engines and electronics located outside the internal chamber of the Master Unit, to avoid overheating, reduce the risk of contamination and increase useful volume. 1 multichannel pumphead per subsystem (2 pumpheads in total) Flow rate Front display control Controlled variables PC-based interface control Controlled variables Temperature, CO2, O2 and flow conditions Flow...

 Open the catalogue to page 2

Windows system requirements Linux system requirements Java Platform Standard Edition 7 Browsers: Internet Explorer 7.0 and above, Firefox 3.6 and above, Chrome Screen resolution: at least 1024 x 768 Ubuntu Linux 10.04 and above Suse Linux Enterprise Server 10 SP2, 11.x Java Platform Standard Edition 7 Browsers: All OS that support versions Firefox 3.6 and above Screen resolution: at least 1024 x 768 Power supply and consumption Power supply Nominal power Dimensions and geometry External dimensions [W x D x H] Opening system Double top door construction Weight Weight

 Open the catalogue to page 3

All Ebers Medical catalogues and technical brochures

  1. TC3 brochure

    2 Pages

    En
  2. TEB500 brochure

    2 Pages

    En
  3. General brochure

    8 Pages

    En
  4. P3D chambers

    2 Pages

    En