Sophie - 4 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

Catalogue excerpts

The innovative ventilation system for neonatology + Dead space free ventilation control with external respiration sensor + Synchronized, non-invasive ventilation + Integrated respiratory gas humidifier + High Frequency Oscillation (HFO) + Ergonomic design

 Open the catalogue to page 1

Sophie The flexible neonatology ventilation system In intensive cooperation with renowned physicians, Fritz Stephan GmbH has succeeded in developing SOPHIE as a neonatology ventilator system based on the proven cutting-edge technology of STEPHANIE thus ensuring highest levels of efficiency, design and operability. With its exibility and performance, SOPHIE can be adapted easily and reliably to the individually required ventilation situation for premature and newborn infants. In addition to conventional and high frequency ventilation strategies it also allows non-invasive ventilation. This system...

 Open the catalogue to page 2

Non-invasive Ventilation (NIV) The benefits of a non-invasive ventilation therapy for newborn or prematurely born babies have been established by several scientific studies (e.g. COIN study). The application of NIV permits lung-protective ventilation strategies thus helping reduce the occurrence of air leak syndromes and BPD. The use of NIPPV reduces the danger of ventilation failure after extubation and therefore significantly reduces the incidence of reintubation. A newly developed system of Fritz Stephan GmbH detects the abdominal movement of patients by means of an external respiration sensor....

 Open the catalogue to page 3

Technical Specifications General specification Patient range Neonates and pediatric patients up to 25 kg bodyweight Class according to 93/42 ECC II b Dimensions 470 x 342 x 332 mm (WxHxD) Weight 26 / 42 kg (w/o /with trolley) Function principle Time cycled, pressure controlled Operational specification Power supply 100 - 240 V AC, 50 - 60 Hz, 210 VA, 24V DC (opt.) Battery backup min. 60 min. (with internal, rechargeable Li-Ion-Battery) Gas supply AIR 2.7 - 6.5 bar O2 2.7 - 6.5 bar Ventilation parameters Ventilation modes PC-IMV, PC-Ass./Cont., PC-SIMV, PC-HFO (opt.), PC-IMV-HFO (opt.), PC-Ass./Con.-ITT,...

 Open the catalogue to page 4

All Fritz Stephan catalogues and technical brochures

  1. EVE

    8 Pages

    En
  2. Akzent X Color

    8 Pages

    En
  3. Christina

    3 Pages

    En
  4. VentSafe

    2 Pages

    En
  5. NGM 1000

    2 Pages

    En
  6. Portec

    3 Pages

    En
  7. EasyFlow nCPAP

    6 Pages

    En
  8. F 120 mobil

    3 Pages

    En
  9. Artec

    3 Pages

    En
  10. Akzent Color

    7 Pages

    En
  11. F 120

    3 Pages

    En

Archived catalogues

  1. MedAir

    3 Pages

    En
  2. Alia

    3 Pages

    En
  3. NeoSID Nova

    3 Pages

    En
  4. Stephanie

    7 Pages

    En