video corpo

CAPSULA XLII
3Pages

{{requestButtons}}

Catalog excerpts

CAPSULA XLII - 1

FUJIFILM FCR CAPSULA XLII Specifications Number of Stacker: 1 Standard Components: • FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359) • AC power cord Reading Gray Scale: 12 bits Network: 10 Base T /100 Base TX Other System Components: • Optional upgrade kit for 50-micron reading with HR-V • IP cassette type CC, LC, CH • CR Console • Dry Imager: DRYPIX 2000, 4000, 7000 Dimensions (W ✕ D ✕ H): 590 ✕ 380 ✕ 810 mm (23” ✕ 15” ✕ 32”) Unit: mm (in.) 380 (15) Supplies: Imaging Plate: • ST-VI: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm • HR-V: 24 ✕ 30 cm*, 18 ✕ 24 cm** 590 (23) 810 (32) IP Cassette: • Type CC: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30 cm • Type LC: 35.4 ✕ 124.5 cm, 35.4 ✕ 101.7 cm, 35.4 ✕ 83.7 cm, 25.2 ✕ 58 cm, 24 ✕ 57 cm • Type CH: 24 ✕ 30 cm*, 18 ✕ 24 cm** (For 50-micron reading with HR-V) FUJI COMPUTED RADIOGRAPHY Time Required for IP Feed /Load: IP Type Required Time ST-VI 35 ✕ 43 cm (14” ✕ 17”) Approx. 58 (41) sec. ST-VI 35 ✕ 35 cm (14” ✕ 14”) Approx. 52 (38) sec. ST-VI 10” ✕ 12” Approx. 49 sec. ST-VI 8” ✕ 10” Approx. 41 sec. ST-VI 24 ✕ 30 cm Approx. 48 sec. ST-VI 18 ✕ 24 cm Approx. 39 sec. ST-VI 15 ✕ 30 cm Approx. 49 sec. HR-V 24 ✕ 30 cm* Approx. 59 sec. HR-V 18 ✕ 24 cm** Approx. 51 sec. • Under “Required Time” in the table above, figures in parentheses are at high-speed mode. • Image erase time on IP is directly related to the exposure made. It is assumed to be at 25mR for ST-VI and 600 mR for HR-V. • The performance described above shows typical values. It varies depending on the exposure level. Processing Capacity IP Type Processing Capacity ST-VI 35 ✕ 43 cm (14” ✕ 17”) Approx. 62 (87) IPs/hr. ST-VI 35 ✕ 35 cm (14” ✕ 14”) 10” ✕ 12” 8” ✕ 10” Approx. 87 IPs/hr. ST-VI 24 ✕ 30 cm 18 ✕ 24 cm 15 ✕ 30 cm Approx. 73 IPs/hr. HR-V 24 ✕ 30 cm* Approx. 61 IPs/hr. HR-V 18 ✕ 24 cm** • Non-operating Conditions: Temperature: 0-45°C Humidity: 10-90%RH (No dew condensation) Approx. 92 IPs/hr. ST-VI Environmental Conditions: • Operating Conditions: Temperature: 15-30°C Humidity: 40-80%RH (No dew condensation) Approx. 75 IPs/hr. ST-VI Power Supply Conditions: Single phase 50-60Hz 120-240V ±10% 5A (max) Approx. 73 IPs/hr. ST-VI and optimal imaging based upon FUJIFILM’s extensive experience. Weight: 99 kg (218 lbs.) Approx. 70 (94) IPs/hr. ST-VI FUJIFILM introduces a compact, all-in-one FCR with extremely clear Approx. 70 IPs/hr. IP Cassette Type CC • Figures in parentheses and conditions are the same as those of “Time Required for IP Feed/Load”. • The time required to change the cassette is assumed to be 0 (zero) seconds. Time to Display on CR Console: • Approx. 42 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading • Approx. 32 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading Time to Print on DRYPIX 4000 through network via CR Console: • Approx. 145 sec. in case of 35 ✕ 43 cm (ST-VI) with 100-micron reading • Approx. 140 sec. in case of 18 ✕ 24 cm (HR-V)** with 50-micron reading Type CH Reading Specification 24 ✕ 30 cm cassette mounted with the cassette adapter Reading Specification Inches Metric Standard Pixel-density High Pixel-density High-speed mode Standard mode 14” ✕ 17” (ST-VI) 35 ✕ 43 cm (ST-VI) 5 pixels/mm 10 pixels/mm 14” ✕ 14” (ST-VI) 35 ✕ 35 cm (ST-VI) 5 pixels/mm 10 pixels/mm 10” ✕ 12” (ST-VI) 24 ✕ 30 cm (ST-VI) – 10 pixels/mm 8” ✕ 10” (ST-VI) 18 ✕ 24 cm (ST-VI) – 10 pixels/mm – 15 ✕ 30 cm (ST-VI) – 10 pixels/mm – 24 ✕ 30 cm (HR-V)* – 20 pixels/mm – 18 ✕ 24 cm (HR-V)** – 20 pixels/mm *Requires the optional upgrade kit and the cassette adaptor. **Requires the optional upgrade kit. Specifications and PC requirements are subject to change without notice. All brand names or trademarks are the property of their respective owners. Ref. No. XB-870E (SK·09·02·F1120·F9711) Printed in Japan ©2007 FUJIFILM Corporation

Open the catalog to page 1
CAPSULA XLII - 2

Worldwide, extensive experience results in confidence for FCR In 1981, FUJIFILM became the world first manufacuturer to successfully digitize X-ray images with FUJIFILM Computed Radiography (FCR). This made it possible to effectively handle diagnostic images in a digital format that constantly provided highly precise, stable images. FUJIFILM has leading installation experience worldwide resulting in confidence to satisfy all users. Compact Frame and Vertical cassette insertion for Effective Work Space FCR CAPSULA XLII is designed for insertion of the IP cassette at an angle to ensure...

Open the catalog to page 2
CAPSULA XLII - 3

FUJIFILM FCR CAPSULA XLII Specifications Number of Stacker: 1 Standard Components: • FCR CAPSULA XLII Image Reader Unit (Model: CR-IR 359) • AC power cord Reading Gray Scale: 12 bits Network: 10 Base T /100 Base TX Other System Components: • Optional upgrade kit for 50-micron reading with HR-V • IP cassette type CC, LC, CH • CR Console • Dry Imager: DRYPIX 2000, 4000, 7000 Dimensions (W ✕ D ✕ H): 590 ✕ 380 ✕ 810 mm (23” ✕ 15” ✕ 32”) Unit: mm (in.) 380 (15) Supplies: Imaging Plate: • ST-VI: 35 ✕ 43 cm (14” ✕ 17”), 35 ✕ 35 cm (14” ✕ 14”), 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm, 15 ✕ 30...

Open the catalog to page 3

All FUJIFILM Europe catalogs and technical brochures

  1. FDR Nano

    5 Pages

  2. FCR PRIMA T2

    3 Pages

  3. SX800

    8 Pages

  4. FDR Go PLUS

    5 Pages

  5. FVS-1000

    4 Pages

  6. FCT Speedia

    7 Pages

  7. Amulet F

    4 Pages

  8. FCRGo2

    3 Pages

  9. RX Evo F

    2 Pages

  10. fcr xg5000

    3 Pages

  11. FCRView

    4 Pages

  12. PRIMA Series

    4 Pages

  13. VELOCITY Tfp

    3 Pages

  14. VELOCITY Ufp

    3 Pages

  15. FCR PRIMA Tm

    3 Pages

  16. FCR PRIMA II

    4 Pages

  17. FCR PRIMA T2

    2 Pages

  18. DRYPIX PRIMA

    3 Pages

  19. DRYPIX7000

    4 Pages

  20. DRYPIX Plus

    2 Pages