Medical Monitoring, Alarm and Control Systems
16Pages

{{requestButtons}}

Catalog excerpts

Medical Monitoring, Alarm and Control Systems - 1

MEDICAL MONITORING, AL ARM AND CONTROL SYSTEMS International Edition Technology for a Better Future

Open the catalog to page 1
Medical Monitoring, Alarm and Control Systems - 2

Company Overview Genstar Technologies Company, Inc. (GENTEC®), founded in1969, is a global industry leader in the manufacturing of welding apparatus, pressure regulators, and gas control systems. It is GENTEC®’s mission to provide customers with high quality, value-added products and services that surpass the strictest safety standards. All GENTEC® products are manufactured in an ISO 9001 and ISO 13485 certified facility by our experienced and dedicated workforce, using exquisite craftsmanship in conjunction with computerized automation, stringent quality control, and advanced test...

Open the catalog to page 2
Medical Monitoring, Alarm and Control Systems - 3

GUMACSTM Overview Medical Gas Area Alarm Medical Gas Master Alarm Medical Gas Combination Alarm Advanced Applications MEDICAL GAS PIPELINE PRODUCTS System Diagram

Open the catalog to page 3
Medical Monitoring, Alarm and Control Systems - 4

MEDICAL GAS FLOW SOLUTIONS Pressure Detecting Point Respiratory Products Patient Room Respiratory Products Operation Room Area Alarm Pressure Detecting Point Area Alarm Air Compressor Cryogenic Tank Manifold System Gentec Universal Monitoring Center Master Alarm Equipment Room

Open the catalog to page 4
Medical Monitoring, Alarm and Control Systems - 5

GUMACSTM Overview Gentec Universal Monitoring, Alarm and Control SystemTM is a highly modular system utilizing the most advanced technologies in electronics and software. The modular design can implement limitless configurations to meet different monitoring/ control requirements. Future expansion can be achieved through upgradable firmware, software, and additional panels. GUMACSTM alarm series complies with the latest edition of NFPA 99 and optionally for HTM 02-01. GUMACSTM alarm series have built-in networking capability and can be implemented to standard RS-485 and Ethernet network...

Open the catalog to page 5
Medical Monitoring, Alarm and Control Systems - 6

GUMACSTM Series Medical Gas Area Alarm Area Alarm with Local Sensors GUMACSTM Series Area Alarm is CE marked and NFPA 99 compliant. Designed to accept a variety of input signals, GUMACSTM Series Area Alarm is often used to monitor pressure, flow rate, temperature, humidity, concentration, and other safety indexes. If needed, GUMACSTM Series Area Alarm can also offer relay switch output control capability. Built-in RS485 communication port allows each GUMACSTM Series alarm to be networked for remote monitoring. The physical data will be processed and displayed on site by the area alarms. In...

Open the catalog to page 6
Medical Monitoring, Alarm and Control Systems - 7

GUMACSTM Series Medical Gas Area Alarm Electrical and Physical Specifications Mechanical Front Panel Injection Molded Plastic (PCABS, V0 Flame Rated) Case Body Metal Alloy Physical Dimension (Width x Height x Depth ) Wall Opening (Width x Height) (Depth beneath the wall is 95mm) 1~4 Channel: 272mm x 125mm Electrical Power Requirements Analog Input Input Type: (1) Single-ended, voltage (3) 4~20 mA current supplying 15 VDC Working Range: ±10 VDC/4~20 mA Safe Range: ±14 VDC/0~28 mA Maximum Resolution: 14 bit or 1% of sensor full range Relay Output Channels: 1 output per 1 input channel Range:...

Open the catalog to page 7
Medical Monitoring, Alarm and Control Systems - 8

GUMACSTM Series Medical Gas Master Alarm Master Alarm (up to 32 inputs) GUMACSTM Series Master Alarm is CE marked and NFPA 99 compliant. It is used to monitor the operation conditions of source equipments such as air compressors, vacuum pumps, and/or manifold systems, etc. GUMACSTM Series Master Alarm can also offer relay switch output control capability when required. Built-in RS485 communication port allows each GUMACSTM Series alarm to be networked for remote monitoring. The physical data will be processed and displayed on site by the master alarm. In addition, GUMACSTM System Console...

Open the catalog to page 8
Medical Monitoring, Alarm and Control Systems - 9

GUMACSTM Series Medical Gas Master Alarm Electrical and Physical Specifications Mechanical Front Panel Injection Molded Plastic (PCABS, V0 Flame Rated) Case Body Metal Alloy Physical Dimension (Width x Height x Depth ) Wall Opening (Width x Height) (Depth beneath the wall is 95mm) 1~16 Channel: 272mm x 125mm 33~48 Channel: 300mm x 285mm Electrical Power Requirements Analog Input (for first module) Input Type: (1) Single-ended, voltage (3) 4~20 mA current supplying 15 VDC Working Range: ±10 VDC/4~20 mA Channels: 16 Maximum Safe Range: ±14 VDC/0~28 mA Maximum Resolution: 14 bit or 1% of...

Open the catalog to page 9
Medical Monitoring, Alarm and Control Systems - 10

GUMACSTM Series Medical Gas Combination Alarm Flexibility of Module Placement GUMACSTM Series Combination Alarm GUMACSTM Series Combination Alarm is CE marked and NFPA 99 compliant. Integrating the numerical display functions and master alarm functions, the combination alarm is sometimes more preferable. It can be used to monitor the operational conditions of source equipment and other numerical safety indexes. GUMACSTM Series Combination Alarm can also offer relay switch output control capability when required. Built-in RS485 communication port allows each GUMACSTM Series alarm to be...

Open the catalog to page 10
Medical Monitoring, Alarm and Control Systems - 11

GUMACSTM Series Medical Gas Combination Alarm Electrical and Physical Specifications Mechanical Front Panel Injection Molded Plastic (PCABS, V0 Flame Rated) Case Body Metal Alloy Physical Dimension Wall Mounting Hole Electrical Power Requirements Analog Input (for first module) Input Type: (1) Single-ended, voltage (2) Differential, voltage (3) 4~20 mA current supplying 15 VDC (4) 4~20 mA current not supplying 15 VDC Working Range: ±10 VDC/4~20 mA Channels: 16 Maximum Safe Range: ±14 VDC/0~28 mA Maximum Resolution: 14 bit or 1% of sensor full range Digital Output (for one expansion module)...

Open the catalog to page 11
Medical Monitoring, Alarm and Control Systems - 12

Advanced Applications Master Alarm Upper Network/ PC/Internet RS485 Network Intelligent Alarm/Control Station/ Logs-Keeping/ Shared folder GUMACSTM System Console GUMACSTM System Console is a powerful industrial PC-based system. As a station host, Intelligent Alarm/Control Station (IACS) can be expanded to monitor a great number of analog/digital inputs and provide output control capabilities. With Gentec customized software, IACS can easily meet or exceed customer’s monitoring requirements. In addition, trend data can be collected and saved for later analysis to help facilitate future...

Open the catalog to page 12
Medical Monitoring, Alarm and Control Systems - 13

Advanced Applications MASTER ALARM MONITORING COMPUTER DATA PROCESSING COMPUTER MASTER ALARM MASTER ALARM AREA ALARM AREA ALARM OPTIONAL ACCESSORIES AREA ALARM MONITORING COMPUTER Gentec Central Monitoring System • Quality control and quality assurance • Trend data analyzing helps decision making, thus improving efficiency of operations management • Can be integrated into existing hospital management system