Catalogue excerpts

Sophisticated microscopy Tradition and Innovation -Since 1858, visionary thinking and a HAAG"STREIT fascination with technology have guided us to develop innovative products of B^B HI i AIIAAJIAA outstanding reliability: Anticipating trends to improve the quality of life. R^l UlnUlNvJd I Iv/O

 Open the catalogue to page 1

THE VERSATILE SLIT LAMP BQ 900 Sophisticated microscopy, outstanding performance Since its introduction in 1958, the famous Goldmann slit lamp BM 900 enjoys remarkable popularity amongst our customers because of its excellent optics and the impressive longevity. As a result, there are well over 100’000 of these original Haag-Streit slit lamps in daily use – including many from the first years of manufacturing. Further innovations have followed to cover more advanced needs in slit lamp examination including the unique stereo variator, a wider range of magnifications and innovative imaging solutions....

 Open the catalogue to page 2

Slit lamp BQ 900 1. LED illumination head 2. Eyepiece with double cross hair reticule 3. Switch for beam splitter 4. Diffusor 5. Pivoting background illumination 6. Imaging Module IM 900 7. Release bar 8. Illumination control

 Open the catalogue to page 3

VERSATILE OPTIONS Wide range of accessories APPLANATION TONOMETER AT 900 The original Goldmann tonometer Because it is fast and reproducible, Goldmann applanation tonometry has been the gold standard in tonometry for many decades. It is based on the Goldmann principle – tried and tested during more than 50 years of usage with millions of patients. Furthermore, thanks to the high precision of manufacturing at HaagStreit the Goldmann applanation tonometer offers reliable performance during many years without the need for manufacturer maintenance. ZOOM OBJECTIVE A view with no limits With the zoom...

 Open the catalogue to page 4

STEREO VARIATOR Enhanced view on fundus Unique to the BQ 900, the stereo variator reduces the angle of stereoscopic observation from 13° to 4.5°. This facilitates the stereoscopic examination of the fundus, peripheral parts of the retina and the vitreous, even under unfavourable conditions such as high myopia and small pupils. The reduction of the angle enlarges the stereoscopic field of view under the described conditions, maintaining depth information in the stereoscopic observation. BEAM SPLITTER STEREO VARIATOR Connection to a wide range of accessories The beam splitter diverts a portion of...

 Open the catalogue to page 5

Excellent optics The quality of the optical system determines the results of whatever application a slit lamp is used for. The BQ 900 is equipped with a elaborated optical system, manufactured for highest quality requirements. The result is a superb view, allowing accurate diagnostics, safe patient treatment and stunning imaging results. Optimum illumination The new LED illumination systems on our slit lamps deliver our sharpest, brightest and most homogeneous slit ever. The light spectrum was specially designed for Haag-Streit to meet the highest quality standards and to achieve results that...

 Open the catalogue to page 6

FROM THE LEADER IN SLIT LAMP IMAGING Imaging Module IM 900 Intuitive imaging – best results The Imaging Module IM 900 is a fully integrated compact imaging solution for the BQ 900 slit lamp. It is equipped with an ultra-sensitive camera which produces images of exceptional quality even under difficult light conditions. Designed for optimal user friendliness it provides you with features which make slit lamp imaging more convenient than ever before. Ideal workflow – no distraction The control panel allows you to operate both the camera and the slit lamp illumination. Located in front of the joystick...

 Open the catalogue to page 7

EyeSuite Platform Flexible interfaces for easy integration into your network The EyeSuite software is designed for optimal patient flow in busy practices. Supporting the Haag-Streit imaging solutions, the software makes the BQ 900 networkable both with other Haag-Streit devices and your practice network. EyeSuite does not require any proprietary third-party software to provide connectivity. If the BQ 900 is connected to an EyeSuite server, all the images taken can be accessed remotely from any number of viewing stations connected to the same database. Furthermore, the EyeSuite Script Language...

 Open the catalogue to page 8

Technical specifications BQ 900 Illumination Instrument base Light-source Slit width Slit length Illumination field diameter Slit image rotatability Swiveling of the slit illumination to the microscope axis Filters Ocular magnification Stereo angle Range of adjusting eye-pieces Pupil distance Magnification changer Object field ø in mm Operation Spatial adjustment of the instrument base LED for examination (slit and background illumination) 0 – 14 mm continuous 1 – 14 mm continuous and fixed apertures ø 8 / 5 / 3 / 2 / 1 / 0.2 mm ± 90° Horizontal ± 90°, vertical 0 – 20° Blue, red-free (green),...

 Open the catalogue to page 9

Members of HAAG-STREIT Group HAAG-STREIT Holding AG IPRO GmbH HAAG-STREIT France EURL HAAG-STREIT Deutschland GmbH HAAG-STREIT Surgical GmbH Möller-Wedel Optical GmbH ©HAAG-STREIT AG, 3098 Koeniz, Switzerland 6. Edition/2015-10

 Open the catalogue to page 10

All Haag-Streit Diagnostics catalogues and technical brochures

  1. Tonosafe

    4 Pages

    En
  2. Lenstar

    14 Pages

    En
  3. MASK-IT

    2 Pages

    En
  4. SLIT LAMPS

    28 Pages

    En
  5. BI 900

    6 Pages

    En
  6. BA 904

    4 Pages

    En
  7. Brochure BQ900 LED

    10 Pages

    En
  8. SLIT LAMP BX 900

    6 Pages

    En
  9. HS 2010

    4 Pages

    En
  10. Octopus® 900

    16 Pages

    En
  11. AT900D

    2 Pages

    En
  12. AT900

    2 Pages

    En
  13. CM900

    2 Pages

    En
  14. IM900

    2 Pages

    En
  15. Brochure Slitlamps

    24 Pages

    En
  16. Lenstar

    12 Pages

    En
  17. Octopus 600

    14 Pages

    En
  18. Stery Cup

    2 Pages

    En
  19. Retina145 L

    2 Pages

    En
  20. Contact G

    12 Pages

    En
  21. HS 1010

    2 Pages

    En
  22. HS 810

    2 Pages

    En
  23. Flyer Correx

    2 Pages

    En
  24. Lenses

    12 Pages

    En
  25. AT 900®D

    2 Pages

    En
  26. EyeSuite Imaging

    4 Pages

    En
  27. EyeCap?

    4 Pages

    En
  28. EyeCap?

    2 Pages

    En
  29. Brochure BQ

    2 Pages

    En
  30. AT-900

    2 Pages

    En
  31. Instrument Table

    2 Pages

    En