EyeSuite Imaging - 4 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

Catalogue excerpts

Image Exposure Guide Diffuse Illumination Slit Illumination Background Level EyeSuite Exposure Open @ 45 degrees, Diffused Diffuse - Conjunctiva Slit Illumination Background Level EyeSuite Exposure Open @45 degrees, Diffused, Tips & Technique *Low magnification - overview images *Open slit fully - slit width can also be used to control exposure * Beware of unwanted reflection artefacts Narrow Slit - Cornea Slit Illumination Background Level EyeSuite Exposure < 0.2mm wide >60 degrees from mic

 Open the catalogue to page 1

Image Exposure Guide EyeSuite IM900 LED Illumination vi.i Narrow Slit - Lens Slit Illumination Background Level EyeSuite Exposure <0.2mm wide >60 degrees from mic Tips & Technique *Slit width must be less than 0.2mm to produce optical section *Maximise angle between illumination and microscope *consider the background *beware of specular reflection Slit Illumination Wide Slit - Cornea Background Level EyeSuite Exposure l-2mm wide, >60 degrees from mic Slit Illumination Background Level EyeSuite Exposure 2-4mm wide, >60 degrees from mic Tips & Technique *Maximise angle of illumination * beware...

 Open the catalogue to page 2

Image Exposure Guide Slit Illumination EyeSuite Exposure Tangential - Iris Slit Illumination >4mm wide, >60 degrees from mic Wide Open, >60 degrees from mic EyeSuite Exposure Tips & Technique *Maximise angle to produce cross lighting *defocus slit can help with iris images * small aperture increases depth of field Sclerotic Scatter Slit Illumination EyeSuite Exposure

 Open the catalogue to page 3

Image Exposure Guide EyeSuite IM900 LED Illumination v1.1 Indirect - Cornea Magnification Slit Illumination Level Background 16x or 25x 1-3mm wide, Decentred, 10 Off Aperture 3 EyeSuite Exposure 1/45 Preset 2 Retro - Lens Magnification 16x or 25x Slit Illumination Level Background 1-2mm wide, < 5 degrees, 10 Off Aperture 3 EyeSuite Exposure 1/90 Preset 1 Fundus Magnification 10x or 16x Slit Illumination Level Background 2-4mm wide 10 Off Aperture 3 EyeSuite Exposure 1/90 Preset 1 These setting are provided as a guide only and changes to slit illumination level and exposure will be required in...

 Open the catalogue to page 4

All Haag-Streit Diagnostics catalogues and technical brochures

  1. Tonosafe

    4 Pages

    En
  2. Lenstar

    14 Pages

    En
  3. MASK-IT

    2 Pages

    En
  4. SLIT LAMPS

    28 Pages

    En
  5. BI 900

    6 Pages

    En
  6. BA 904

    4 Pages

    En
  7. BQ 900

    10 Pages

    En
  8. Brochure BQ900 LED

    10 Pages

    En
  9. SLIT LAMP BX 900

    6 Pages

    En
  10. HS 2010

    4 Pages

    En
  11. Octopus® 900

    16 Pages

    En
  12. AT900D

    2 Pages

    En
  13. AT900

    2 Pages

    En
  14. CM900

    2 Pages

    En
  15. IM900

    2 Pages

    En
  16. Brochure Slitlamps

    24 Pages

    En
  17. Lenstar

    12 Pages

    En
  18. Octopus 600

    14 Pages

    En
  19. Stery Cup

    2 Pages

    En
  20. Retina145 L

    2 Pages

    En
  21. Contact G

    12 Pages

    En
  22. HS 1010

    2 Pages

    En
  23. HS 810

    2 Pages

    En
  24. Flyer Correx

    2 Pages

    En
  25. Lenses

    12 Pages

    En
  26. AT 900®D

    2 Pages

    En
  27. EyeCap?

    4 Pages

    En
  28. EyeCap?

    2 Pages

    En
  29. Brochure BQ

    2 Pages

    En
  30. AT-900

    2 Pages

    En
  31. Instrument Table

    2 Pages

    En