Octopus 600 - 14 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

Catalogue excerpts

Octopus 600 See the new pulse in perimetry Tradition and Innovation – Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating trends to improve the quality of life.

 Open the catalogue to page 1

OCTOPUS 600 Perimetry simplified In 1972 Franz Fankhauser and others developed the principles and concepts of automated perimetry which resulted in the design of the first automated static perimeter, the Octopus 201, in 1974. Since then, Octopus has pioneered many significant innovations like the G-pattern, the direct projection system, fast strategies and outstanding software for visual field analysis. Detecting visual field loss at the earliest possible stage, defining the optimum treatment and following up the patient to decide on the necessity of treatment changes or surgery are the main tasks...

 Open the catalogue to page 2

Early diagnosis and standard white-on-white perimetry in one device The Octopus 600 extends the successful Haag-Streit product range of visual field analyzers, combining the Pulsar method for early glaucoma detection and standard white-on-white perimetry for long term followup in a single compact, standalone device. Perimetry simplified The same, easy to use EyeSuite software already known from the Octopus 900 has been further streamlined to operate the Octopus 600. The intuitive concept of both the examination and viewing screens are the key components of the new touch screen optimized user interface. Fast...

 Open the catalogue to page 3

OCTOPUS 600 Expert in early glaucoma detection and follow-up With the Octopus 600, Haag-Streit has introduced a new perimetry technology that makes use of a TFT-based monitor to produce stimuli and background. This allows the instrument to display complex stimuli such as Pulsar, which would otherwise not be possible with cupola-based or projection type perimeters. Combining both Pulsar early glaucoma detection and standard white-on-white perimetry, the instrument is capable of covering the most important stages of disease progression, allowing for early diagnosis and follow-up. Early diagnosis Disease...

 Open the catalogue to page 4

PULSAR METHOD Early glaucoma detection made easy Pulsar is a patented1 flicker stimulus, displaying a ring pattern with different contrast levels in counterphase. As independent studies confirm, the test is easy – even pleasant – to take, while being both sensitive and specific in the detection of early glaucoma. Unlike other early diagnostic methods, that challenge the patient with hardto-distinguish answering criteria, Pulsar requires no more than a simple click for every target that appears. Combined with our proven TOP fast-thresholding strategy, the Pulsar examination method delivers fast...

 Open the catalogue to page 5

Perimetry simplified Outstanding usability and ergonomics for both patient and operator The Octopus 600 can produce reliable visual field results with minimal user training and it doesn’t take an expert to run a reliable field. The same, easy to use EyeSuite software already known from the Octopus 900 has been further streamlined to operate the Octopus 600. The intuitive concept of both the examination and viewing screens are the key components of the touch screen optimized user interface. Has perimetry ever been a Large trial lenses Trial lenses for spherical corrections between –8 dpt and +4...

 Open the catalogue to page 6

EyeSuite Perimetry optimized for touch screen The Octopus 600 is operated with a touch screen optimized version of EyeSuite. Quick-start icons for Pulsar, standard white-onwhite or Follow-Up as well as a redesigned examination screen make the Octopus 600 very easy to use – perimetry simplified. It fits anywhere The Octopus 600 has a small, compact design allowing for a minimal footprint. Add in silent operation with no fans or motors and you have a perimeter that can be placed anywhere in your office. The few clicks needed to operate the perimeter can easily be done at the side by the receptionist. It...

 Open the catalogue to page 7

Pulsar Early diagnosis “Pulsar test is a rapid and easy perimetric method, showing higher sensitivity than SAP in detecting early glaucomatous visual field loss.” 4 In the late nineties, Prof. González de la Rosa started to develop a new stimulus method that combines the modulation of spatial resolution and contrast while at the same time containing a flickering component. The primary focus was to develop a method that is more sensitive in detecting early visual field defects as well as being simple for the patient to answer: seen or not seen. The Pulsar stimulus consists of two images, the phase...

 Open the catalogue to page 8

NERVE FIBER BUNDLES CLUSTER ANALYSIS Providing meaningful results Cluster analysis combines high sensitivity with good specificity. Test locations are grouped (clustered) along nerve fiber bundles to better analyze changes in crucial areas like the nasal step or the macula. This 7 eliminates the time-consuming method of counting isolated points. A combined pro5 bability/deviation graph highlights pathologic regions. POLAR GRAPH Combining structure and function CLUSTER ANALYSIS Combining the results of both structure and function (A) is key in obtaining a comprehensive assessment for the onset...

 Open the catalogue to page 9

Visual field evaluation is made simple with

 Open the catalogue to page 10

2 – 4’ TOP 6 – 8’ DYNAMIC TOP FAST-THRESHOLDING STRATEGY Increased efficiency Tendency oriented perimetry (TOP) presents the maximum in fast threshold testing by reducing the examination time by nearly 80% to just over two minutes compared to 6–8 minutes (Dynamic strategy) or 10–12 minutes (Normal strategy). The TOP algorithm is a systematic method which takes into account correlation of the threshold values in neighboring locations. 10 –12’ NORMAL TIME COMPARISON BETWEEN TEST STRATEGIES As the Pulsar method exclusively uses the TOP fast-thresholding strategy, the Octopus Program Gp (Glaucoma,...

 Open the catalogue to page 11

Connectivity is key Open data and intuitive user interfaces for optimal workflow The EyeSuite software is designed for optimum patient flow in busy practices. As employed on the Octopus 600, it is very easy to use and also permits reviewing the data of every parameter in detail. With EyeSuite software, Octopus 600 is fully networkable and, if connected to an EyeSuite Server, it allows full real-time access to all data in a practice. EyeSuite does not require any proprietary third-party software applications to provide connectivity and results can be viewed on any number of viewing stations connected...

 Open the catalogue to page 12

All Haag-Streit Diagnostics catalogues and technical brochures

  1. Tonosafe

    4 Pages

    En
  2. Lenstar

    14 Pages

    En
  3. MASK-IT

    2 Pages

    En
  4. SLIT LAMPS

    28 Pages

    En
  5. BI 900

    6 Pages

    En
  6. BA 904

    4 Pages

    En
  7. BQ 900

    10 Pages

    En
  8. Brochure BQ900 LED

    10 Pages

    En
  9. SLIT LAMP BX 900

    6 Pages

    En
  10. HS 2010

    4 Pages

    En
  11. Octopus® 900

    16 Pages

    En
  12. AT900D

    2 Pages

    En
  13. AT900

    2 Pages

    En
  14. CM900

    2 Pages

    En
  15. IM900

    2 Pages

    En
  16. Brochure Slitlamps

    24 Pages

    En
  17. Lenstar

    12 Pages

    En
  18. Stery Cup

    2 Pages

    En
  19. Retina145 L

    2 Pages

    En
  20. Contact G

    12 Pages

    En
  21. HS 1010

    2 Pages

    En
  22. HS 810

    2 Pages

    En
  23. Flyer Correx

    2 Pages

    En
  24. Lenses

    12 Pages

    En
  25. AT 900®D

    2 Pages

    En
  26. EyeSuite Imaging

    4 Pages

    En
  27. EyeCap?

    4 Pages

    En
  28. EyeCap?

    2 Pages

    En
  29. Brochure BQ

    2 Pages

    En
  30. AT-900

    2 Pages

    En
  31. Instrument Table

    2 Pages

    En