Model 498KL
23Pages

{{requestButtons}}

Catalog excerpts

Model 498KL - 1

Model 498KL Remote Display Digital Scale User Instructions

Open the catalog to page 1
Model 498KL - 2

Model 498KL Thank you for your purchase of this Health o meter® Professional product. Please read this manual carefully, and keep it for easy reference or training. Note: This scale has been factory calibrated, and does not require calibration prior to use. Please register your scale for warranty coverage at: http://www.homscales.com/customer/registration.aspx For User Instructions updates and revisions please go to: http://www.homscales.com

Open the catalog to page 2
Model 498KL - 3

To prevent injury and damage to your scale, please follow these instructions very carefully. Assemble and operate the scale per the enclosed user instructions. For accurate weighing, this scale must be placed on a flat, stable surface. For accurate weighing, verify before each use the proper operation according to the procedure described in this manual. Operating this scale at voltages and frequencies other than specified can damage the equipment and will void the warranty. Do not transport the scale with any weight on the platform. Do not exceed recommended weight limit of 500 lb / 220 kg...

Open the catalog to page 3
Model 498KL - 4

SPECIFICATIONS FOR THIS SCALE General The Model 498KL remote display digital scale uses highly sophisticated microprocessor technology. Each precision scale is designed to provide accurate, reliable and repeatable weight measurements. In addition, each scale is designed to provide the user with features that make the weighing process simple, fast, and convenient. This scale is set up to use motion-sensing weighing technology in order to determine the actual weight of a moving patient. Weight can be displayed in pounds (lb) or in kilograms (kg). For privacy and convenience in use, the scale...

Open the catalog to page 4
Model 498KL - 5

CERTIFICATIONS / CONNECTIVITY / DISPOSAL Certification Descriptions Pelstar, LLC has been officially certified as the manufacturer of Health o meter® Professional medical devices. The Pelstar, LLC quality assurance system covers the development, production, sales and service of medical scales and measuring systems. This product is tested to and meets the requirements of: 1. UL60601-1 First Edition: Safety for Medical Electrical Equipment 2. CSA C22.2 No. 601-1 M90: Medical Electrical Equipment 498KL Scale Connectivity Information To enable reliable transmission of weight, height, and Body...

Open the catalog to page 5
Model 498KL - 6

498KL ASSEMBLY INSTRUCTIONS Before Assembly Each 498KL remote display digital scale is shipped disassembled in one carton. Carefully inspect the carton for shipping damage before unpacking. If damage is found, contact your shipper or a Health o meter® Professional representative immediately at 1-800-815-6615. Claims must be filed with the shipper as soon as possible after receipt of the package. The following information details what you will find inside the main carton as you unpack the parts for assembly. To prevent scratching any components, carefully remove each assembly from the carton...

Open the catalog to page 6
Model 498KL - 7

498KL ASSEMBLY INSTRUCTIONS (CONTINUED) Assembling the 498KL Scale (Refer to Figures 1 – 4) Note: For wall mounting, mount display assembly directly to the wall do not use display bracket for wall mount. Display bracket is for surface use only. 1. Carefully remove the scale platform with the display assembly from the carton, and place the scale platform and display assembly on a flat, level, and dry surface (see Figure 3). 2. Ensure that the cable is securely connected to the scale platform RJ jack (see Figures 2 & 3). 3. Remove the display bracket from the carton (see Figure 1). 4. Remove...

Open the catalog to page 7
Model 498KL - 8

498KL ASSEMBLY INSTRUCTIONS (CONTINUED) Display Bracket Mounting studs Screws Center tab Plate A Screw holes Scale platform Adaptor Jack

Open the catalog to page 8
Model 498KL - 9

498KL ASSEMBLY INSTRUCTIONS (CONTINUED) Scale platform Display assembly RJ jack

Open the catalog to page 9
Model 498KL - 10

DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS Display Assembly Wall Mounting Instructions (Refer to Figure 4) Caution: When wall mounting the display assembly, ensure that the mounting location is free of electrical lines, gas pipes, and other safety hazards. Ensure that wall is of construction that can support the display assembly. Note: Remote head can be mounted to a wall up to 6 feet (1.83 m) from the base or it can be mounted on the display bracket (included) for placement on a table up to 6 feet (1.83 m) from the base. Note: For wall mounting, mount display assembly directly to the wall do...

Open the catalog to page 10
Model 498KL - 11

DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS (CONT) Display assembly Mounting hole Mounting hole

Open the catalog to page 11
Model 498KL - 12

SETUP / BATTERIES / TRANSPORT Preparing the 498KL Scale for Use Replacing / Inserting Batteries 1. Remove the protective plastic film covering the display (the film says “FACTORY CALIBRATED”). 2. Unplug the optional AC adapter, if connected to a power source. 3. Use a Phillips head screwdriver to remove the battery cover on the side of the display assembly by unscrewing the (2) battery cover screws (see Figure 5). 4. Replace or install the batteries with new units. Health o meter recommends using an alkaline or lithium battery, rated for 130°F (54°C) operation. Do not use zinc-carbon...

Open the catalog to page 12
Model 498KL - 13

SETUP / BATTERIES / TRANSPORT (CONTINUED) 1. Remove the protective plastic film covering the display (the film says “FACTORY CALIBRATED”). 2. Connect the optional AC adapter into the adaptor jack on the scale platform (see Figure 2). Warning: To avoid a safety hazard, use AC adapter model ADPT30 (International, plug kit) or ADPT31 (Domestic, USA). 3. Plug the scale’s AC adapter into the power source. 4. Ensure all objects are removed from the scale’s assembly. Press the ON/OFF button to turn the scale on. The display will show “Start”, then “0.0” LB or “0.0” KG. Press the LB/KG button to...

Open the catalog to page 13
Model 498KL - 14

SETUP / BATTERIES / TRANSPORT (CONTINUED) Preparing a 498KL Scale for Transport This scale can be easily placed into carrying case (# 64771) for storage, or transport from one room to another. This scale does not include the carrying case item # 64771, and must be acquired separately (see Figure 6). To prepare the scale for transport, follow these steps: 1. Remove the display assembly and display bracket from its current position. 2. Unplug the AC adapter and USB cable from the scale platform, and remove the AC adapter from the outlet. 3. Carefully store the AC adapter, display bracket, and...

Open the catalog to page 14

All Health O meter Professional catalogs and technical brochures

  1. 894KLT

    2 Pages

  2. 3400KG

    2 Pages

  3. 2600KL

    2 Pages

  4. 3001KL-AMX

    2 Pages

  5. 2000KL

    2 Pages

  6. 142KL

    2 Pages

  7. 160KG

    2 Pages

  8. 160LB

    2 Pages

  9. 160KL

    2 Pages

  10. 400KL

    2 Pages

  11. BCS-G6

    2 Pages

  12. 499KLHR

    2 Pages

  13. PORTROD

    1 Pages

  14. Model 2101KL

    21 Pages

  15. Model 600KL

    13 Pages

  16. Model 349KLX

    23 Pages

  17. 597KL

    2 Pages

  18. 594KL

    2 Pages

  19. 499KL

    2 Pages

Archived catalogs

  1. 596KL

    2 Pages

  2. 222KL

    2 Pages