Catalog excerpts
UK-P1-MED-0230-201410-02 IAC Acoustics IAC House, Moorside Road, Winchester Hampshire, SO23 7US, United Kingdom T: +44 (0) 1962 873 000 www.iac-acoustics.com Specification and Dimensional Data Sheet 120a Series Double Walled Audiometric Booth External Width Examination Room Internal Depth External Depth Internal Width Room Height Weight (kg) Room Details The IAC 120a series is a range of double-walled booths for individual or multiple occupancy. © 2014 IAC Acoustics Door Opening: 838mm wide x 1857mm high Window Clear View: 750mm wide x 600mm high Ventilation: A further 370mm should be added to the width, depth or height of the booth, depending on the preferred location of the ventilation system Noise Reduction & Sound Absorption Noise Reduction*: The minimum allowable noise reduction of completely assembled rooms, as tested in accordance with ASTM Standards in a recognised independent and approved laboratory, as shown in the table below. Octave Band Centre Frequency (Hz) 125 Noise Reduction (dB) for Double Wall Booths Sound Absorption Coefficient Sound Absorption: The composite sheet metal and sound absorbing assembly shall have a sound absorption coefficient based on laboratory tests in accordance with ASTM C423-77 as shown in the table below. 120.0 Double Wall Single Wall Noise-reduction measurements shall be made in accordance with the following ASTM Designations: E596 and, where applicable, portions of E90 and E336. * Defined as the measured difference between the sound pressure levels in a reverberant room, outside the booth and inside the booth. Octave Band Center Frequency, Hz. making the world a quieter place Uncontrolled copy when printed
Open the catalog to page 1UK-P1-MED-0230-201410-02 IAC Acoustics IAC House, Moorside Road, Winchester Hampshire, SO23 7US, United Kingdom T: +44 (0) 1962 873 000 www.iac-acoustics.com Specification and Dimensional Data Sheet 120a Series Double Walled Audiometric Booth Roof & Wall Construction Roofs and walls are constructed from standard IAC Noise-Lock® 2 acoustic panels, 102mm thick. Average weights are no less than 50kg/m2. Floor Construction IAC Acousti-flote™ floors shall be 50mm high and structurally reinforced. All floors are carpeted. Average weights are no less than 90kg/m2. Floors float on properly loaded...
Open the catalog to page 2All Iac Acoustics catalogs and technical brochures
-
Quiet-Duct® Silencers
8 Pages
-
Marine Mounts - VS, VM & VB
1 Pages
-
Round Cone Mounts - DRD
2 Pages
-
Round Cone Mounts - DSD
2 Pages
-
Rubber Buffers - GB
2 Pages
-
Rubber Metal Rails - GMS
3 Pages
-
Rubber Pads - MF
1 Pages
-
Rubber Pads (ribbed) - RG8
1 Pages
-
Rubber Turret Mounts - FA
1 Pages
-
Rubber Turret Mounts - FAV
2 Pages
-
Sandwich Mount - VIKASH
1 Pages
-
Seismic Spring Mount - SSM
1 Pages
-
Seismic Spring Mount - SSM2
1 Pages
-
Absorption Systems
3 Pages
-
Radio 24-7
2 Pages
-
Peregrines Pianos
2 Pages
-
NBC Universal
2 Pages
-
Kobalt Music Group
3 Pages
-
IMG Studios
2 Pages
-
Herning Hearing
2 Pages
-
Financial Times
3 Pages
-
Dolby
2 Pages
-
Copenhagen University
2 Pages
-
BBC Mailbox
4 Pages
-
Trackwall Brochure
4 Pages
-
Varitone Absorption Panels
3 Pages
-
Security Rooms
3 Pages
-
Police Interview Rooms
5 Pages
-
Acoustic Barriers Brochure
7 Pages
-
Audiology Facilities
25 Pages
-
Audiometric Rooms
6 Pages
-
Audiometric Booths
4 Pages
Archived catalogs
-
Audiology Brochure
25 Pages
-
350 Series Data Sheet
2 Pages
-
250 Series Data Sheet
2 Pages