Implants trauma Cannulated Tibia Nail

Open the catalog to page 1
CTN - Cannulated Tibia Nail - 3

1. introduction P. 5 Preface P. 6 Screw P. 6 Properties P. 7 Pre-operative measurement of nail Length P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Pre-operative patient planning P. 10 Incision P. 11 Assembly of the insertion guide P. 12 Locating entry portal P. 12 Nailing P. 13 Proximal Locking P. 14 Measuring of proximal screw length P. 15 Distal Locking P. 16 Measuring of distal screw length P. 17 Removal of the insertion guide P. 17 Endcap insertion P. 19 Postoperative treatment P. 19 Nail removal 3. Information P. 21 Dotize® P. 22 Order list P. 26 Reconditioning Manual

Open the catalog to page 3
CTN - Cannulated Tibia Nail - 5

Preface The newly developed CTN - Cannulated Tibia Nail enables the surgical treatment of various fractures of the tibia. Stable, ridged fixation of fractures can be achieved, with the advantage of early weight bearing due to intramedullary insertion.

Open the catalog to page 5
CTN - Cannulated Tibia Nail - 6

Spiral Drill, D=4.2mm, L=350mm, AO Connector Spiral Drill, Angledrived, D=4.2mm, L=140mm Shank, PRS, Solid, WS 3.5, L=230mm, AO Connector Properties Properties of the material: • Nail material: TiAl6V4 ELI • Material of screw: TiAl6V4 ELI • Easier removal of the implant if necessary • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy • Anatomically shaped • Radiolucent insertion guide • Intramedullary insertion allows early weight bearing • Multi-direction proximal Locking • Dynamic interlock options to allow for fracture...

Open the catalog to page 6
CTN - Cannulated Tibia Nail - 7

1. Determine the nail length with the template (see right) and a X-Ray Pre-operative measurement of nail length Scale 1.6:1 2. Determine the nail length with the X-Ray ruler (59205). 3. Insert the calibrated D=3.0mm guide wire with ball tip (35301-800) or the D=2.5mm guide wire (35251-800) and read off the required nail length at the calibrated guide wire.

Open the catalog to page 7
CTN - Cannulated Tibia Nail - 8

Indications: ♦ Proximal, metaphyseal, diaphyseal and distal metaphyseal fractures ♦ Simple, segmental and comminuted fractures • Open fractures of the tibia ♦ Surgical correction of non-unions, mal-unions and delayed unions ♦ Pathological fractures ♦ Fractures involving osteopenic and osteoporotic bone Contraindications: ♦ Active infection near the fracture site ♦ Skeletally immature patients ♦ Severe osteoporosis or inadequate bone stock ♦ Skin and soft tissue problems ♦ Foreign body (material) sensitivity ♦ Obesity ♦ Lack of patient compliance

Open the catalog to page 8
CTN - Cannulated Tibia Nail - 9

Surgical Technique

Open the catalog to page 9
CTN - Cannulated Tibia Nail - 10

Pre-operative patient planning • Surgical planning depends on the operative technique individually preferred. • In most cases, the patient should be placed supine on a standard radiolucent operating room table. Incision Entry point depends surgeon‘s preference: • • • • Suprapatellar (green line) Medial to the patellar ligament Through the patellar ligament Lateral to the patell

Open the catalog to page 10
CTN - Cannulated Tibia Nail - 11

Assembly of the insertion guide fastening with the flatwrench, WS 20 (70020) fastening with the socket wrench, WS 10, L=250mm (561002-250) To attach the jig to the handle, rotate the spinning fastener clockwise. Turn it until it stops and move it into the provided slots (highlighted in yellow). Advice: To verify the correct assembly of the insertion guide, insert a tissue protection sleeve and a drill sleeve into a guide hole in the jig. Then push the drill through the drill sleeve in the appropriate nail interlock hole.

Open the catalog to page 11
CTN - Cannulated Tibia Nail - 12

• The entry portal for the insertion of a tibiaL nail is very important. • The individual anatomy should be carefully evaluated. • The insertion point should be in line with the medullary canal on the AP fluoroscopy view (just medial to the lateral tibial eminence) and just on the anterior roll over of the tibia plateau on the lateral fluoroscopy view. • Open the medullary canal with the required drill, awl or gimlet to the desired diameter. • Introduce the D=3.0mm guide wire with ball tip (35301-800) when using the optional available reamer down to the level of the fracture, reduce the...

Open the catalog to page 12
CTN - Cannulated Tibia Nail - 13

Proximal Locking • For the proximal Locking the jig is attached to the handle with the spinning fastener (see page 11). • The circular holes on the handle provide static locking with rotational and axial stability. • Dynamic locking can be carried out with a sleeve (1180087) inserted in the oblong hole and provides rotation stability with axial compression on weight bearing. Static Locking: eccentric hole distal Dynamic Locking: eccentric hole proximal • Insert the trochar (118008-8) through the D=4.3mm drill sleeve (118008-6) and advance to the cortex through a stab incision. • Remove the...

Open the catalog to page 13
CTN - Cannulated Tibia Nail - 14

Measuring of proximal screw length Drilling of the screw holes under fluoroscopy can be done. Once the far cortex is drilled the length can be read off the calibrated D=4.2mm spiral drill (61423-350).

Open the catalog to page 14
CTN - Cannulated Tibia Nail - 15

Distal Locking • Distal locking is carried out using fluoroscopy and perfect circle technique. • Before locking, the correct reduction should be verified. • The spiral drill, angledrived, D=4.2mm, L=140mm, AO Connector (61427-140), is used to drill through the near and far cortex. • Measure the screw length. • Insert a D=4.7mm cortical screw (32475-XX) of appropriate length determined previously. • Verify the correct screw position under fluoroscopy. Attention: Do not overtighten the sc

Open the catalog to page 15
CTN - Cannulated Tibia Nail - 16

Measuring of distal screw length The distal screw length may also be determined using the standard depth gauge from the solid small fragment screws set (59022).

Open the catalog to page 16
CTN - Cannulated Tibia Nail - 17

Removal of the insertion guide For disassembly of the insertion guide (118008) release the fastening screw (118008-4) with the socket wrench, WS 10, L=250mm (561002-250) and remove it. Endcap insertion Finally screw the endcap with the screwdriver shank, PRS, solid, WS 3.5mm, L=230mm, AO Connector (54353-230SH) into the proximal end of the nail, which will protect the internal thread of the tibia nail against tissue growth, thus facilitating removal of the implant at a later date.

Open the catalog to page 17

All I.T.S. catalogs and technical brochures

  1. ufs

    1 Pages

  2. DHL

    2 Pages

  3. ITS

    2 Pages

  4. PHL

    24 Pages

  5. ACLS

    20 Pages

  6. CFN

    32 Pages

  7. OLS

    24 Pages

  8. PHLs

    20 Pages

  9. SR Sacral Rods

    20 Pages

  10. HCS

    24 Pages

  11. TLS

    20 Pages

  12. PRS-RX

    32 Pages

  13. HLS

    20 Pages

  14. ES

    20 Pages

  15. SR

    20 Pages

  16. FL

    24 Pages

  17. CAS

    40 Pages

  18. FCN

    20 Pages

  19. HOL

    24 Pages

  20. FLS

    24 Pages

  21. PFL

    20 Pages

  22. DTL

    24 Pages

  23. HTO

    24 Pages

  24. PTL

    32 Pages

  25. DFL

    32 Pages

  26. SCL

    32 Pages

  27. SLS

    24 Pages

  28. CAL

    20 Pages

  29. DUL

    24 Pages

  30. CLS

    28 Pages

Archived catalogs

  1. SR Old

    20 Pages

  2. ES Old

    20 Pages

  3. CAS Old

    36 Pages

  4. CS

    16 Pages

  5. SN Old

    16 Pages

  6. FCN Old

    16 Pages

  7. DFL Old

    28 Pages

  8. FTN

    12 Pages

  9. PRS

    28 Pages

  10. PRL

    28 Pages

  11. UOL

    32 Pages

  12. SL

    16 Pages

  13. OHL

    24 Pages

  14. OL

    16 Pages

  15. DHL

    16 Pages

  16. PHL

    16 Pages

  17. CLS

    24 Pages