EPIPHYSIS SCREW emergency team for broken bones®

Open the catalog to page 1
ES Old - 2

• crew material: TiAl6V4 ELI S • Easy removal of the implant after fracture healing • Increased fatigue strenth of the implants • Decreased risk of infection and allergy • annulated Spongiosa Tension C Screw with constant 10 mm thread • ore diameter 5 mm C • uter diameter 6.5 mm O • ength: 50 - 120 mm in 5 mm L steps • annulation: 3.5 mm for Ø 3.2 C mm Guide Wire • elfdrilling & selfcutting S EPIPHYSIS SCREW emergency team for broken bones® Indications • he indication for the use of a T transcutaneous screw holds for all acute, acute to chronic and chronic loosening of the epiphysis •...

Open the catalog to page 2
ES Old - 3

back-tapping flank large countersink head for easy removableness EPIPHYSIS SCREW

Open the catalog to page 3
ES Old - 4

Slipped Capital Femoral Epiphysis [SCFE] ECF is a disease of young people and occurs round about sexual maturity. Slippage of the head of the femur occurs on the growth groove. This is really misnamed since it is not the femoral head that moves but rather the metaphysis of the neck of the femur that slips forwards and upwards while the head of the femur is held in the acetabulum by the ligamentum capitis femoris (Fig.1). The problem of this disease is the occurrence of complications such as avascular necrosis or chondrolysis of the head of the femur. Each of these complications can lead to...

Open the catalog to page 4
ES Old - 5

Preparation of Operation INSTRUMENTS REQUIRED: Extension table and two image intensifiers. EPIPHYSIS SCREW

Open the catalog to page 5
ES Old - 6

EPIPHYSIS SCREW emergency team for broken bones® The patient is placed on the extension table and two image intensifiers are arranged in such a way that the proximal end of the femur can be represented in two planes. The image intensifiers have to be placed in such a way that the X-ray tubes can be positioned respectively above (A-P level) and between the legs (sagittal level) in order to protect the operating team from X-rays as best as possible. The patient is placed on the extension table with carefully internally rotated leg (neutralising the femoral torsion). Care must be taken not to...

Open the catalog to page 6
ES Old - 7

EPIPHYSIS SCREW Surgical Technique First step: In the A-P plane, a free Kirschner’s wire is placed centrally over the course of the neck of the femur while being checked with the image converter and fastened to the skin using adhesive strip. This wire determines the middle of the neck of the femur in the A-P plane and thus all possible entry points of the cannulated screw.

Open the catalog to page 7
ES Old - 8

Second step: Under observation from the image intensifiers in the lateral plane, the point at the centre of the neck of the femur in the A-P plane (where the Kirschner’s wire was attached earlier) is determined to allow an additional central attachment to the epiphysis of the head of the femur in the sagittal plane. The greater the slippage of the head of the femur, the further ventral is the point of entry, and thus the steeper the Kirschner’s wire must be in the lateral plane. EPIPHYSIS SCREW emergency team for broken bones® Insertion of the Kirschner’s wire under observation from the...

Open the catalog to page 8
ES Old - 9

Third step: Before the measuring device is placed in position, the incision lateral to the guide wire is made larger. Fourth step: Using the measuring device, the length of the appropriate hollow screw is determined. It is necessary, however, to take the distance from the joint into account and therefore to choose a screw some 0.5 cm longer since the Kirschner’s wire stops about 1 cm in front of the joint cavity. EPIPHYSIS SCREW

Open the catalog to page 9
ES Old - 10

Fifth step: Screw in the hollow screw above the guide wire under observation from the image intensifiers in both planes. Care must be taken not to perforate the joint. EPIPHYSIS SCREW emergency team for broken bones®

Open the catalog to page 10
ES Old - 11

Sixth and last step: Screw out the guide wire, release the leg, and check mobility using the image intensifiers. Care must be taken not to perforate the joint! EPIPHYSIS SCREW It is important not to countersink the bolt head into the bone, otherwise the easy percutaneous removeableness will not be able. Because of the short screw threat you can use the screw also as a „dynamic“ one. This means that you should retighten the screw due to the growth. For that the head of the screw must stick out from the bone 0.5 – 1 cm (fig.).

Open the catalog to page 11
ES Old - 12

EPIPHYSIS SCREW emergency team for broken bones® Attaching the screw on the other side The same procedure as in the steps of the operation, except that the guide wire is inserted parallel to the Kirschner’s wire fastened to the skin distal to the tuberculum inominatum.

Open the catalog to page 12
ES Old - 13

Removing the screw Removal of the epiphysis screw is carried out after closure of the growth groove and checked using the image intensifiers, and is carried out percutaneously. EPIPHYSIS SCREW A guide wire starting from the scar of the screw attachment is introduced into the funnel shaped screw head of the epiphysis screw and the latter removed by means of the T-handle along with the guide wire.

Open the catalog to page 13
ES Old - 14

Implants & Instruments EPIPHYSIS SCREW emergency team for broken bones® Epiphysis Screw, D=6.5mm, L=50mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=55mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=60mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=65mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=70mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=75mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=80mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=85mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=90mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=95mm, 10mm Thread Epiphysis Screw, D=6.5mm, L=100mm, 10mm Thread Epiphysis Screw,...

Open the catalog to page 14
ES Old - 15

EPIPHYSIS SCREW Socket Wrench, WS 10, L=250mm, Epiph. Screw Guide Wire, Steel, D=3.2mm, L=260 mm, TR, w. Thrd. Depth Gauge 3.2mm, L=260mm, Epiphys. Wire Sterilization Tray, Epiphysis Screw

Open the catalog to page 15
ES Old - 16

Chemical process - anodization in a strong alkaline solution * Type III anodization Dotize Type II anodization Different colors Film become an interstitial part of the titanium Implant surface remains sensitive to: Chipping Peeling Discoloration No visible cosmetical effect Anodization Type II leads to following benefits * • • • • • • • • Oxygen and silicon absorbing conversion layer Decrease in protein adsorption Closing of micro pores and micro cracks Reduced risk of inflammation and allergy Hardened titanium surface Reduced tendency of cold welding of titanium implants Increased fatigue...

Open the catalog to page 16

All I.T.S. catalogs and technical brochures

  1. ufs

    1 Pages

  2. DHL

    2 Pages

  3. ITS

    2 Pages

  4. PHL

    24 Pages

  5. ACLS

    20 Pages

  6. CFN

    32 Pages

  7. OLS

    24 Pages

  8. PHLs

    20 Pages

  9. SR Sacral Rods

    20 Pages

  10. HCS

    24 Pages

  11. TLS

    20 Pages

  12. PRS-RX

    32 Pages

  13. HLS

    20 Pages

  14. ES

    20 Pages

  15. SR

    20 Pages

  16. FL

    24 Pages

  17. CAS

    40 Pages

  18. FCN

    20 Pages

  19. HOL

    24 Pages

  20. FLS

    24 Pages

  21. PFL

    20 Pages

  22. DTL

    24 Pages

  23. HTO

    24 Pages

  24. PTL

    32 Pages

  25. DFL

    32 Pages

  26. SCL

    32 Pages

  27. SLS

    24 Pages

  28. CAL

    20 Pages

  29. DUL

    24 Pages

  30. CLS

    28 Pages

Archived catalogs

  1. SR Old

    20 Pages

  2. CAS Old

    36 Pages

  3. CS

    16 Pages

  4. SN Old

    16 Pages

  5. FCN Old

    16 Pages

  6. DFL Old

    28 Pages

  7. FTN

    12 Pages

  8. PRS

    28 Pages

  9. PRL

    28 Pages

  10. UOL

    32 Pages

  11. SL

    16 Pages

  12. OHL

    24 Pages

  13. OL

    16 Pages

  14. DHL

    16 Pages

  15. PHL

    16 Pages

  16. CLS

    24 Pages