HTO - 1

Implants trauma High Tibia Osteotomy Plate

Open the catalog to page 1
HTO - 2

All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent several times. This is particularly important in the case of titanium implants, to prevent material fatigue and subsequent failure. The method of bending is the conscious responsibility of the operating doctor;...

Open the catalog to page 2
HTO - 3

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 7 Instruments P. 8 Advantages of the „Closed Wedge“ Technique P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Access P. 11 Exposure P. 12 Implantation P. 13 Compression instrument P. 15 Postoperative treatment P. 15 Explantation P. 15 Summary 3. Information P. 17 Locking P. 17 Dotize® P. 18 Order list P. 20 Reconditioning Manual P. 22 Notes

Open the catalog to page 3
HTO - 5

Preface The locking Tibia Head Plate is anatomically preshaped and is fixed laterally. The preshaping leads to reduced operation times since an intraoperative anatomical contouring no longer needs to be performed. All holes are occupied in a locking way thus ensuring an early ability to bear weight without any loss of correction.

Open the catalog to page 5
HTO - 6

37451-xx Cortical Screw, Locking, D=4.8mm 61408-225 Spiral DriLL, D=4.0mm, L=225mm, AO Connector Mill Mill MM lllllllllllllllllllllll III Mill Mill MM lllll III lllllllllllllll llll Mil MM lllllll^

Open the catalog to page 6
HTO - 7

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy Locking Anatomically contoured Left/right version Stable plate with ability to bear weight early on without loss of correction • Plate lenght: 6-hole Instruments Tension bolts: • Tension bolt A is fixed on the tibia slightly ventral to the plate • Tension bolt B is fixed in one of the two plate holes Compression...

Open the catalog to page 7
HTO - 8

Advantages of the „Closed Wedge“ Technique • • • • Fast osseous restoration times - 2 planar bony areas are apposed under compression Immediate load stability - 3 weeks partial weight bearing - then full weight bearing Adjusted correction angle and adjusted tibial slope are held exactly No loss of correction due to worse bone quality Indications & Contraindications Indications: • Tibia-head osteotomy with valgus („Closed Wedge“ Technique) • Femoral osteotomy with varus („Closed Wedge“ Technique) Existing infections in the fracture zone and operation area Common situations that do not allow...

Open the catalog to page 8
HTO - 9

Surgical Technique

Open the catalog to page 9
HTO - 10

Pre-operative patient preparation • Body position is the same as for arthroscopy, which is routinely performed before the osteotomy • Additionally, a roll is pushed under the bone in order to bend the knee to about 20° in order to protect the neurovascular structures in the hollow of the knee. Access • Lateral approach of about 6cm length at the height of the proximal tibia, viewed laterally at the centre of the lower leg, between tub. tibiae and palpable head of the fibula. • First, the lig. patellae is displayed, the anterior musculature of the tibia is transversely separated from the...

Open the catalog to page 10
HTO - 11

Exposure • Next, the guide wires for the osteotomy are drilled (check using fluoroscopy). • For this purpose an angle gauge (6820202-1) is used to display an accurate guidance for the D=3.2mm guide wire • First of all, the guide wire, steel, D=3.2mm, L=170mm (35324-170) is attached and fastened in the blind hole with the 0 mark using the appropriate fixation screw (6820202-2). • The second long guide wire, steel, D=3.2mm, L=228mm (35324-228) is subsequently drilled in, in such a way that both wires meet each other at the medial cortex of the tibia. • After checking the angle of the planned...

Open the catalog to page 11
HTO - 12

Implantation The locking plate is positioned laterally and then fastened to the head of the shin bone using the three screws running parallel to the articular surface. Use the drill guide, D=4.0mm (62401-88) to bore holes with the spiral drill, D=4.0mm, L=225mm, AO Connector (61408-225) into the proximal plate holes. Read off the required screw length at the calibrated spiral drill and insert D=4.8mm locking cortial screws (37481-XX), using the screwdriver, WS 3.5, conic, self-holding (56352-SH). Then fix the tension bolt, 4x13 (70102-40/13) in one of the two plate holes (see picture...

Open the catalog to page 12
HTO - 13

Compression instrument For the closure of the osteotomy, a compression device (70100) has been developed which engages two tension bolts. Through rotation of the T-handpiece the osteotomy can be closed tightly without any problems.

Open the catalog to page 13
HTO - 14

For the final positioning of the three distal plate holes, the compression instrument can be tilted without losing any tension, in a ventral or dorsal direction, in order to be able to insert the screws. Weight bearing stability is thus provided. The axis is now once more intraoperatively checked (if required, using computer navigation). The musculature is refixed onto the head of the tibia, a drain is put in place, and the wound closed.

Open the catalog to page 14
HTO - 15

Postoperative treatment • The drain is removed on the first postoperative day, and mobilisation is started with the patient. • After exposure to partial weight bearing for three weeks and in case of an uneventful course, the patient can start walking with full weight. • Osseous restoration is achieved after 4 - 6 weeks according to radiography. • Patients are discharged from treatment on average 6 - 7 weeks after the osteotomy has healed. • Thrombosis prophylaxis is carried out for 4 - 6 weeks. Explantation If desired by the patient, the implant can be removed. Removal should be performed...

Open the catalog to page 15

All I.T.S. catalogs and technical brochures

  1. ufs

    1 Pages

  2. DHL

    2 Pages

  3. ITS

    2 Pages

  4. PHL

    24 Pages

  5. ACLS

    20 Pages

  6. CFN

    32 Pages

  7. OLS

    24 Pages

  8. PHLs

    20 Pages

  9. SR Sacral Rods

    20 Pages

  10. HCS

    24 Pages

  11. TLS

    20 Pages

  12. PRS-RX

    32 Pages

  13. HLS

    20 Pages

  14. ES

    20 Pages

  15. SR

    20 Pages

  16. FL

    24 Pages

  17. CAS

    40 Pages

  18. FCN

    20 Pages

  19. HOL

    24 Pages

  20. FLS

    24 Pages

  21. PFL

    20 Pages

  22. DTL

    24 Pages

  23. PTL

    32 Pages

  24. DFL

    32 Pages

  25. SCL

    32 Pages

  26. SLS

    24 Pages

  27. CAL

    20 Pages

  28. DUL

    24 Pages

  29. CLS

    28 Pages

Archived catalogs

  1. SR Old

    20 Pages

  2. ES Old

    20 Pages

  3. CAS Old

    36 Pages

  4. CS

    16 Pages

  5. SN Old

    16 Pages

  6. FCN Old

    16 Pages

  7. DFL Old

    28 Pages

  8. FTN

    12 Pages

  9. PRS

    28 Pages

  10. PRL

    28 Pages

  11. UOL

    32 Pages

  12. SL

    16 Pages

  13. OHL

    24 Pages

  14. OL

    16 Pages

  15. DHL

    16 Pages

  16. PHL

    16 Pages

  17. CLS

    24 Pages