Implants trauma High Tibia Osteotomy Plate

 Open the catalogue to page 1

All ITS plates are preformed anatomically as a matter of principle. If adjustment of the plate to the shape of the bone is required, this is possible by carefully bending gently in one direction once. Particular care is required when bending in the region of a plate hole, as deformation of the plate may lead to a failure of the locking mechanism. The plate must not be buckled or bent several times. This is particularly important in the case of titanium implants, to prevent material fatigue and subsequent failure. The method of bending is the conscious responsibility of the operating doctor; I.T.S....

 Open the catalogue to page 2

1. Introduction P. 5 Preface P. 6 Screws P. 7 Properties P. 7 Instruments P. 8 Advantages of the „Closed Wedge“ Technique P. 8 Indications & Contraindications 2. Surgical Technique P. 10 Pre-operative patient preparation P. 10 Access P. 11 Exposure P. 12 Implantation P. 13 Compression instrument P. 15 Postoperative treatment P. 15 Explantation P. 15 Summary 3. Information P. 17 Locking P. 17 Dotize® P. 18 Order list P. 20 Reconditioning Manual P. 22 Notes

 Open the catalogue to page 3

Preface The locking Tibia Head Plate is anatomically preshaped and is fixed laterally. The preshaping leads to reduced operation times since an intraoperative anatomical contouring no longer needs to be performed. All holes are occupied in a locking way thus ensuring an early ability to bear weight without any loss of correction.

 Open the catalogue to page 5

37451-xx Cortical Screw, Locking, D=4.8mm 61408-225 Spiral DriLL, D=4.0mm, L=225mm, AO Connector Mill Mill MM lllllllllllllllllllllll III Mill Mill MM lllll III lllllllllllllll llll Mil MM lllllll^

 Open the catalogue to page 6

Properties Properties of the material: • Plate material: Titanium • Material of screws: TiAl6V4 ELI • Easier removal of the implant after the fracture has healed • Improved fatigue strength of the implant • Reduced risk of cold welding • Reduced risk of inflammation and allergy Locking Anatomically contoured Left/right version Stable plate with ability to bear weight early on without loss of correction • Plate lenght: 6-hole Instruments Tension bolts: • Tension bolt A is fixed on the tibia slightly ventral to the plate • Tension bolt B is fixed in one of the two plate holes Compression instrument:...

 Open the catalogue to page 7

Advantages of the „Closed Wedge“ Technique • • • • Fast osseous restoration times - 2 planar bony areas are apposed under compression Immediate load stability - 3 weeks partial weight bearing - then full weight bearing Adjusted correction angle and adjusted tibial slope are held exactly No loss of correction due to worse bone quality Indications & Contraindications Indications: • Tibia-head osteotomy with valgus („Closed Wedge“ Technique) • Femoral osteotomy with varus („Closed Wedge“ Technique) Existing infections in the fracture zone and operation area Common situations that do not allow osteosynthesis...

 Open the catalogue to page 8

Pre-operative patient preparation • Body position is the same as for arthroscopy, which is routinely performed before the osteotomy • Additionally, a roll is pushed under the bone in order to bend the knee to about 20° in order to protect the neurovascular structures in the hollow of the knee. Access • Lateral approach of about 6cm length at the height of the proximal tibia, viewed laterally at the centre of the lower leg, between tub. tibiae and palpable head of the fibula. • First, the lig. patellae is displayed, the anterior musculature of the tibia is transversely separated from the shin bone,...

 Open the catalogue to page 10

Exposure • Next, the guide wires for the osteotomy are drilled (check using fluoroscopy). • For this purpose an angle gauge (6820202-1) is used to display an accurate guidance for the D=3.2mm guide wire • First of all, the guide wire, steel, D=3.2mm, L=170mm (35324-170) is attached and fastened in the blind hole with the 0 mark using the appropriate fixation screw (6820202-2). • The second long guide wire, steel, D=3.2mm, L=228mm (35324-228) is subsequently drilled in, in such a way that both wires meet each other at the medial cortex of the tibia. • After checking the angle of the planned osteotomy...

 Open the catalogue to page 11

Implantation The locking plate is positioned laterally and then fastened to the head of the shin bone using the three screws running parallel to the articular surface. Use the drill guide, D=4.0mm (62401-88) to bore holes with the spiral drill, D=4.0mm, L=225mm, AO Connector (61408-225) into the proximal plate holes. Read off the required screw length at the calibrated spiral drill and insert D=4.8mm locking cortial screws (37481-XX), using the screwdriver, WS 3.5, conic, self-holding (56352-SH). Then fix the tension bolt, 4x13 (70102-40/13) in one of the two plate holes (see picture below). The...

 Open the catalogue to page 12

Compression instrument For the closure of the osteotomy, a compression device (70100) has been developed which engages two tension bolts. Through rotation of the T-handpiece the osteotomy can be closed tightly without any problems.

 Open the catalogue to page 13

For the final positioning of the three distal plate holes, the compression instrument can be tilted without losing any tension, in a ventral or dorsal direction, in order to be able to insert the screws. Weight bearing stability is thus provided. The axis is now once more intraoperatively checked (if required, using computer navigation). The musculature is refixed onto the head of the tibia, a drain is put in place, and the wound closed.

 Open the catalogue to page 14

Postoperative treatment • The drain is removed on the first postoperative day, and mobilisation is started with the patient. • After exposure to partial weight bearing for three weeks and in case of an uneventful course, the patient can start walking with full weight. • Osseous restoration is achieved after 4 - 6 weeks according to radiography. • Patients are discharged from treatment on average 6 - 7 weeks after the osteotomy has healed. • Thrombosis prophylaxis is carried out for 4 - 6 weeks. Explantation If desired by the patient, the implant can be removed. Removal should be performed at the...

 Open the catalogue to page 15

All I.T.S. catalogues and technical brochures

  1. CFN

    32 Pages

    En
  2. OLS

    24 Pages

    En
  3. PHLs

    20 Pages

    En
  4. SR Sacral Rods

    20 Pages

    En
  5. HCS

    24 Pages

    En
  6. TLS

    20 Pages

    En
  7. PRS-RX

    32 Pages

    En
  8. HLS

    20 Pages

    En
  9. ufs

    20 Pages

    En
  10. ES

    20 Pages

    En
  11. SR

    20 Pages

    En
  12. FL

    24 Pages

    En
  13. PHL

    20 Pages

    En
  14. CAS

    40 Pages

    En
  15. FCN

    20 Pages

    En
  16. HOL

    24 Pages

    En
  17. FLS

    24 Pages

    En
  18. PFL

    20 Pages

    En
  19. DTL

    24 Pages

    En
  20. PTL

    32 Pages

    En
  21. DFL

    32 Pages

    En
  22. SCL

    32 Pages

    En
  23. SLS

    24 Pages

    En
  24. CAL

    20 Pages

    En
  25. DUL

    24 Pages

    En
  26. CLS

    28 Pages

    En

Archived catalogues

  1. SR Old

    20 Pages

    En
  2. ES Old

    20 Pages

    En
  3. CAS Old

    36 Pages

    En
  4. CS

    16 Pages

    En
  5. SN Old

    16 Pages

    En
  6. FCN Old

    16 Pages

    En
  7. DFL Old

    28 Pages

    En
  8. FTN

    12 Pages

    En
  9. PRS

    28 Pages

    En
  10. PRL

    28 Pages

    En
  11. UOL

    32 Pages

    En
  12. SL

    16 Pages

    En
  13. OHL

    24 Pages

    En
  14. OL

    16 Pages

    En
  15. DHL

    16 Pages

    En
  16. PHL

    16 Pages

    En
  17. CLS

    24 Pages

    En