• Products
  • Catalogues
  • News & Trends
  • Exhibitions

CS 2000 / Tomo - 2 Pages

  1. P. 1

  2. P. 2

Catalogue excerpts

CS 2000 Easy operation from the front The central operation of the tube stand and the automatic Bucky coupler guarantees convenient operation. When leaving the Bucky travel range the Bucky uncouples automatically, then re-couples when the tube stand is returned to the Bucky position. Versatile installation The rail system is easily installed for right or left hand side operation depending on the Bucky stand preference. Longitudinal movement at right hand version: 1500 mm, 580 mm to the left, 920 mm to the right (see small photo below). Easy patient positioning with the smooth movement of the table top The table top is released by the extensive foot treadle and moves 600 mm to the left, 500 mm to the right, and ±120 mm transversely. Excellent radiographic quality The table top is specially constructed for low radiation absorption and the shortest possible object-to-film distance. The CS 2000 will accept Bucky assemblies of all manufacturers with full movement over the entire length of the table base. Optimum tube movement ț Longitudinal movement installed for left hand side operation: 1500 mm, 920 mm to the left, 580 mm to the right (see large photo below). ț Film to floor distance: min. 420 mm, max. 1900 mm ț Tube rotation movement: ± 120° with 90° catches ț Column rotation movement: ± 90° for lateral exposures CS 2000 Tomo With a fully integrated, microprocessor controlled attachment for linear tomography. Tomo exposures are available with angels 40°, 30°, 20° and 8° with two different speeds each. Tomographic object-to-film distance of 1000 mm or 1150 mm. Operation? Easy and safe! The operator is directed by a display on the control panel. Fulcrum tower and tube coupling are no longer needed. This reduces the danger of injuries and the access to the patient is possible from each side.

 Open the catalogue to page 1

* Installation Wall Bucky Stand right hand side (optional) ** FFA = 1300 max.; 1000 to 1150 for Tomography *** required room height for installation Accessories ț Patient hand grips ț Patient positioning pad ț Compression device ț Head and hip clamps ț Lateral cassette holder ț Tübingen patellar positioning device Alterations to the construction and technical data are possible in the cause of technical improvement without prior notice. All rights reserved. Reproduction in any form or the use of extracts require the prior agreement of K&S Röntgenwerk Bochum.

 Open the catalogue to page 2

All K&S Röntgenwerk Bochum catalogues and technical brochures

  1. XRV Sub System

    6 Pages

    En
  2. Lorad LPX Series

    6 Pages

    En
  3. XRV

    4 Pages

    En
  4. Cosmos-2

    2 Pages

    En
  5. Toplift

    2 Pages

    En
  6. BS 2000 V / VK

    2 Pages

    En
  7. Generator

    2 Pages

    En