Dipha - 1

Dipha One – Amplifier – Multiple Uses Dipha® is the first of a new class of data acquisition systems opening the digital world for electrophysiology. Dipha® is based on a new concept for the collection and transmission of signals: one amplifier for multiple uses. Data acquisition and pre-processing takes place in a light weight, smartphone sized, battery powered amplifier. Measurement data is transmitted with low power from the Dipha® amplifier to a transceiver USB dongle connected to a Personal Computer or Notebook placed at a distance of up to 10 meters. The connector header contains a chip with a unique application specific number that is broadcast when the electrode head is placed on the amplifier. A computer, licensed to recognize the assembly number, automatically makes contact with the Dipha® amplifier. A docking station serves as battery charger and as traveling case for the Dipha® ampl

Open the catalog to page 1
Dipha - 2

Dipha® amplifier MEASUREMENT SYSTEM The Dipha® amplifier contains a Digital Reference Amplifier with 16 measurement channels. The true DC Digital Reference Amplifier has especially been designed for the measurement of sensitive electro-physiological signals. Extremely high input impedances and very low input noise currents enable high quality measurements even with electrode impedances being more than 10 times higher as in common practice. The upper trace shows cable movement artefacts from uncoated shielded cables. During the same test coated shielded cables show a small EMG signal and no...

Open the catalog to page 2
Dipha - 3

THE APPLICATION The application has the look and feel suited to the professional user and not to the biomedical engineer or software developer so the user is focused on the patient and not on the computer screen. The general idea is that Dipha® applications should give answers on simple formulated questions about physiological parameters measured by electro-physiological means. Applications therefore start at the result end of measurements in the form of a report containing information ranging from a single number to tables and figures. All known tools and activities leading to this report...

Open the catalog to page 3
Dipha - 4

SPECIFICATIONS AMPLIFIER Amplifier type Number of Channels Input Impedance Voltage Range Signal Range Resolution Aggregate Sample Frequency CMRR @ 50(60) Hz Input Noise Voltage @ 0.1-10 Hz Reference Amplifier 2-16 > 2GΩ 4 Vpp 400 mVpp 24 bit 8kHz > 100 dB < 1.2 μVpp TRANSMISSION Frequency band Transmission Protocol Range Rechargeable Battery Life MACAWI medical systems Science Park Eindhoven 5709 5692 EP Son +31 88 6222949 www.macawi.com info@macawi.com 2.4 GHz Spread Spectrum, proprietary protocol 10 m 24 hours

Open the catalog to page 4