IOCHEMISTRY PRODUCTS Test results are traceable to primary reference measurement procedure (IFCC 2002} to Alanine Aminotransferase (ALT) Assay Kit • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs 2008 RE LA EQA Result 2009 RELA EQA Result 2010 RELA EQA Result 2011 RELA EQA Result Order information: >s( This kit does not include the calibrator, please purchase the calibrator indiv

 Open the catalogue to page 2

IOCHEMISTRY PRODUCTS Test results are traceable to primary reference measurement procedure (IFCC 2002} to Aspartate Aminotransferase (AST) Assay Kit • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs 2010 RELA EQA Result 2011 RELA EQA Result Order information: )*( This kit does not include the calibrator, please purchase the calibra

 Open the catalogue to page 3

Test results are traceable to primary reference measurement procedure (IFCC • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-80C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs Order information:

 Open the catalogue to page 4

Test results are traceable to reference measurement procedure (Doumas 1981) to Total Protein (TP) Assay Kit Based on Doumas Method • Liquid reagent, saving on-board position, ready for use. • The reagent can be stable for 12 months when stored at 20C-80C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS Total protein Order information : This kit does not include the calibrator, please purchase the calibrator indivi

 Open the catalogue to page 5

Test results are traceable to manufacturer' s selected measurement procedure (Improved J-G method) to ensure the Direct Bilirubin (DBIL) Assay Kit Based on Oxidizing Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days Order information : >& This kit does not include the calibrator, please purchase

 Open the catalogue to page 6

Adenosine Deaminase (ADA) Assay Kit Based on Enzymatic Method Test results are traceable to reference material (BCR-647) to ensure the accuracy • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 20C-8°C and protected from light. It can be stable on-board for 30 days Order information : >s( This kit does not include the calibrator, please purchase the calibrator

 Open the catalogue to page 7

Test results are traceable to reference measurement procedure (CDC Recommend) Urea (Urea) Assay Kit UV-GLDH Method Single Reagent • Liquid reagent, saving on-board position, ready for use • Measurement range 0.24-35.00 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 15 days Order information : 38$ This kit does not include the calibrator, please purchase t

 Open the catalogue to page 8

Test results are traceable to reference material Based on Latex Enhanced Immunoturbidimetric Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days Order information: * This kit does not include the calibrator, please purchase the calibrat

 Open the catalogue to page 9

Test results are traceable to reference Recommend) to ensure the accuracy Based on GOD-PAP Method (Single Reagent) • Liquid reagent, saving on-board position,ready for use • Measurement range 0.03-22.30 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase th

 Open the catalogue to page 10

• Two liquid reagents, ready for use • Measurement range 0.05-4.00 mmol/L • The reagent can be stable for 12 months when stored at 2CC-8°C and protected from light. It can be stable on-board for 30 days Order information: ^ This kit does not include the calibrator, please purchase the c

 Open the catalogue to page 11

Test results are traceable to reference measurement procedure (CDC NetLab-BMG) Certify by CDC Cholesterol reference method laboratory network High Density Lipoprotein Cholesterol (HDL-C) • Two liquid reagents, ready for use • Measurement range 0.03-3.10 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days • CAT method.two steps reaction: first step is to remove other lipoprotein except for HDL-C, the second is to react with HDL-C. Higher specificity Order information:

 Open the catalogue to page 12

Based on Latex Enhanced Immunoturbidimetric Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days Order information: This kit does not include the calibrator, please purchase the calibr

 Open the catalogue to page 13

a-Hydroxybutyrate Dehydrogenase (a-HBDH) Based on DGKC Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 20C-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase the calibrator individua

 Open the catalogue to page 14

IOCHEMISTRY PRODUCTS Creatine Kinase Isoenzyme MB (CK-MB) Assay Kit Based on Selective Inhibition Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2CC-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase the calibrator individu