Biochemistry/Clinical chemistry reagents
25Pages

{{requestButtons}}

Catalog excerpts

Biochemistry/Clinical chemistry reagents - 1

Maker's over 100 products which are developed independently achieve the international level of traceability studies. This provides a reliable guarantee for the results of assay. Take specification as standard of kit components.

Open the catalog to page 1
Biochemistry/Clinical chemistry reagents - 2

IOCHEMISTRY PRODUCTS Test results are traceable to primary reference measurement procedure (IFCC 2002} to Alanine Aminotransferase (ALT) Assay Kit • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs 2008 RE LA EQA Result 2009 RELA EQA Result 2010 RELA EQA Result 2011 RELA EQA Result Order information: >s( This kit does not include the calibrator, please purchase the calibrator indiv

Open the catalog to page 2
Biochemistry/Clinical chemistry reagents - 3

IOCHEMISTRY PRODUCTS Test results are traceable to primary reference measurement procedure (IFCC 2002} to Aspartate Aminotransferase (AST) Assay Kit • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs 2010 RELA EQA Result 2011 RELA EQA Result Order information: )*( This kit does not include the calibrator, please purchase the calibra

Open the catalog to page 3
Biochemistry/Clinical chemistry reagents - 4

Test results are traceable to primary reference measurement procedure (IFCC • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-80C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS and NCCL's EQAs Order information:

Open the catalog to page 4
Biochemistry/Clinical chemistry reagents - 5

Test results are traceable to reference measurement procedure (Doumas 1981) to Total Protein (TP) Assay Kit Based on Doumas Method • Liquid reagent, saving on-board position, ready for use. • The reagent can be stable for 12 months when stored at 20C-80C and protected from light. It can be stable on-board for 30 days • Excellent results in IFCC-RELA-EQAS Total protein Order information : This kit does not include the calibrator, please purchase the calibrator indivi

Open the catalog to page 5
Biochemistry/Clinical chemistry reagents - 6

Test results are traceable to manufacturer' s selected measurement procedure (Improved J-G method) to ensure the Direct Bilirubin (DBIL) Assay Kit Based on Oxidizing Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days Order information : >& This kit does not include the calibrator, please purchase

Open the catalog to page 6
Biochemistry/Clinical chemistry reagents - 7

Adenosine Deaminase (ADA) Assay Kit Based on Enzymatic Method Test results are traceable to reference material (BCR-647) to ensure the accuracy • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 20C-8°C and protected from light. It can be stable on-board for 30 days Order information : >s( This kit does not include the calibrator, please purchase the calibrator

Open the catalog to page 7
Biochemistry/Clinical chemistry reagents - 8

Test results are traceable to reference measurement procedure (CDC Recommend) Urea (Urea) Assay Kit UV-GLDH Method Single Reagent • Liquid reagent, saving on-board position, ready for use • Measurement range 0.24-35.00 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 15 days Order information : 38$ This kit does not include the calibrator, please purchase t

Open the catalog to page 8
Biochemistry/Clinical chemistry reagents - 9

Test results are traceable to reference material Based on Latex Enhanced Immunoturbidimetric Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days Order information: * This kit does not include the calibrator, please purchase the calibrat

Open the catalog to page 9
Biochemistry/Clinical chemistry reagents - 10

Test results are traceable to reference Recommend) to ensure the accuracy Based on GOD-PAP Method (Single Reagent) • Liquid reagent, saving on-board position,ready for use • Measurement range 0.03-22.30 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase th

Open the catalog to page 10
Biochemistry/Clinical chemistry reagents - 11

• Two liquid reagents, ready for use • Measurement range 0.05-4.00 mmol/L • The reagent can be stable for 12 months when stored at 2CC-8°C and protected from light. It can be stable on-board for 30 days Order information: ^ This kit does not include the calibrator, please purchase the c

Open the catalog to page 11
Biochemistry/Clinical chemistry reagents - 12

Test results are traceable to reference measurement procedure (CDC NetLab-BMG) Certify by CDC Cholesterol reference method laboratory network High Density Lipoprotein Cholesterol (HDL-C) • Two liquid reagents, ready for use • Measurement range 0.03-3.10 mmol/L • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days • CAT method.two steps reaction: first step is to remove other lipoprotein except for HDL-C, the second is to react with HDL-C. Higher specificity Order information:

Open the catalog to page 12
Biochemistry/Clinical chemistry reagents - 13

Based on Latex Enhanced Immunoturbidimetric Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2°C-8°C and protected from light. It can be stable on-board for 28 days Order information: This kit does not include the calibrator, please purchase the calibr

Open the catalog to page 13
Biochemistry/Clinical chemistry reagents - 14

a-Hydroxybutyrate Dehydrogenase (a-HBDH) Based on DGKC Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 20C-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase the calibrator individua

Open the catalog to page 14
Biochemistry/Clinical chemistry reagents - 15

IOCHEMISTRY PRODUCTS Creatine Kinase Isoenzyme MB (CK-MB) Assay Kit Based on Selective Inhibition Method • Two liquid reagents, ready for use • The reagent can be stable for 12 months when stored at 2CC-8°C and protected from light. It can be stable on-board for 30 days Order information: This kit does not include the calibrator, please purchase the calibrator individu

Open the catalog to page 15

All Maccura Biotechnology Co. catalogs and technical brochures