Technical Specifications medinCNO®mini
3Pages

{{requestButtons}}

Catalog excerpts

Technical Specifications medinCNO®mini - 1

The medinCNOmini nCPAP device is used in combination with the Medijet® nCPAP generator or with medin Nuflow® nasal cannulas to administer nCPAP or High Flow therapy to premature infants and newborns. Specification Display Data CPAP Push pressure Apnea time Push flow Tinsp. Trigger Safety External data Oxygen cell Computer controlled electronic blender with integrated oxygen sensor; flow and pressure controlled, range 0 to 17,5 l/min (flow working area 4 to 10 l/min; additional flow during inspiration push up to max 17,5 l/min minus set basis flow; in 0,1 l/min steps) 3,0 to 6,0 bar (Air and Oxygen) DISS or NIST Internal battery, 14,4 V DC, operating time 3 hours, rechargeable; External power supply 100 -240 V AC 50/60 Hz 7,0"LCD multi-colour; 800 x 480 Pixel Patient pressure 0 to 20 mbar (diagram and measurement) Trend: CPAP, FiO2, RR, Push frequency, Flow - up to 28 days Measured from 0 to 18 mbar (in 0,1 mbar steps) Push pressure - measured up to 15,0 mbar (in 0,1 mbar steps) Push time limited to max 2 sec (in 0,1 sec steps), manual and automatic Measured respiratory frequency; 1 - 120 bpm; in CPAP and Apnea CPAP mode 2,0 to 30,0 sec (in 0,1 sec steps) Additional push flow 0 to 17,5 l/min minus adjusted flow; in 0,1 l/min steps) 0,2 to 2,0 sec (in 0,1 sec steps) Medijet pressure trigger based on the CPAP pressure sensitivity; ±0,2 to ±2,0 mbar (in 0,1 mbar steps) Oxygen concentration 21 to 100 % (in 1 % steps), alarm settings: +/- 2, 3, 4, 5% difference Optical, visual and audible (adjustable as push alarm); central alarm integrated Mechanical overpressure valve, electronic shut off valve USB port, export of live and trend data Oxygen cell with lifetime of 3 years medrriA Hamilton Medical Company

Open the catalog to page 1
Technical Specifications medinCNO®mini - 2

CPAP Standard CPAP; with additional function: Leak-Assist; (±2 l/min to keep target pressure) Apnea CPAP CPAP with Apnea detection (automatically generated push); with additional function: Backup (Backup Rate: 5-120/min as a function of Ti (mininum 0,2 sec)) NIPPV NIPPV (5-120/min as a function of Ti (mininum 0,2 sec)); I:E proportion 1:1 High flow Maximum adjustable flow: 12 l/min; adjustable O2-Flush Pressure units mbar or cmH2O Scale of pressure Three adjustments: 0-10. 0-15 and 0-20 mbar/cmH2O Class of protection Class II equipment Declaration CE Marked product...

Open the catalog to page 2
Technical Specifications medinCNO®mini - 3

Warranty Period Humidification (recommended) Hamilton Medical Accessories Generator Water trap (gas supply) Manufacturer: medin Medical Innovations GmbH Adam-Geisler-Straße 1 82140 Olching, Germany Specifications are subject to change without notice. Some features are options. Not all features are available in all markets. For all proprietary trademarks and third-party trademarks used by medin Medical Innovations GmbH see www.medin-medical.com/trademarks. © 2017 medin Medical Innovations GmbH. All rights reserved

Open the catalog to page 3

All Medin Medical Innovations GmbH catalogs and technical brochures

  1. Nuflow®

    2 Pages

  2. Pb_1000_long

    3 Pages

  3. OP_Medijet

    103 Pages

  4. Pb_4000_long

    3 Pages

  5. OP_Miniflow

    103 Pages

  6. OP Bubble

    2 Pages

  7. Processing

    4 Pages

  8. Pb_1207_long

    2 Pages

  9. PB_1207MKI

    2 Pages

  10. PB_1207

    2 Pages

Archived catalogs

  1. MEDINsindi

    2 Pages

  2. Medin_Catalog

    16 Pages

  3. OP_Blender

    18 Pages

  4. OP_Medijet_1000

    104 Pages

  5. products_medin

    16 Pages