Group: Hamilton Medical AG
Catalog excerpts
The medinCNOmini nCPAP device is used in combination with the Medijet® nCPAP generator or with medin Nuflow® nasal cannulas to administer nCPAP or High Flow therapy to premature infants and newborns. Specification Display Data CPAP Push pressure Apnea time Push flow Tinsp. Trigger Safety External data Oxygen cell Computer controlled electronic blender with integrated oxygen sensor; flow and pressure controlled, range 0 to 17,5 l/min (flow working area 4 to 10 l/min; additional flow during inspiration push up to max 17,5 l/min minus set basis flow; in 0,1 l/min steps) 3,0 to 6,0 bar (Air and Oxygen) DISS or NIST Internal battery, 14,4 V DC, operating time 3 hours, rechargeable; External power supply 100 -240 V AC 50/60 Hz 7,0"LCD multi-colour; 800 x 480 Pixel Patient pressure 0 to 20 mbar (diagram and measurement) Trend: CPAP, FiO2, RR, Push frequency, Flow - up to 28 days Measured from 0 to 18 mbar (in 0,1 mbar steps) Push pressure - measured up to 15,0 mbar (in 0,1 mbar steps) Push time limited to max 2 sec (in 0,1 sec steps), manual and automatic Measured respiratory frequency; 1 - 120 bpm; in CPAP and Apnea CPAP mode 2,0 to 30,0 sec (in 0,1 sec steps) Additional push flow 0 to 17,5 l/min minus adjusted flow; in 0,1 l/min steps) 0,2 to 2,0 sec (in 0,1 sec steps) Medijet pressure trigger based on the CPAP pressure sensitivity; ±0,2 to ±2,0 mbar (in 0,1 mbar steps) Oxygen concentration 21 to 100 % (in 1 % steps), alarm settings: +/- 2, 3, 4, 5% difference Optical, visual and audible (adjustable as push alarm); central alarm integrated Mechanical overpressure valve, electronic shut off valve USB port, export of live and trend data Oxygen cell with lifetime of 3 years medrriA Hamilton Medical Company
Open the catalog to page 1CPAP Standard CPAP; with additional function: Leak-Assist; (±2 l/min to keep target pressure) Apnea CPAP CPAP with Apnea detection (automatically generated push); with additional function: Backup (Backup Rate: 5-120/min as a function of Ti (mininum 0,2 sec)) NIPPV NIPPV (5-120/min as a function of Ti (mininum 0,2 sec)); I:E proportion 1:1 High flow Maximum adjustable flow: 12 l/min; adjustable O2-Flush Pressure units mbar or cmH2O Scale of pressure Three adjustments: 0-10. 0-15 and 0-20 mbar/cmH2O Class of protection Class II equipment Declaration CE Marked product...
Open the catalog to page 2Warranty Period Humidification (recommended) Hamilton Medical Accessories Generator Water trap (gas supply) Manufacturer: medin Medical Innovations GmbH Adam-Geisler-Straße 1 82140 Olching, Germany Specifications are subject to change without notice. Some features are options. Not all features are available in all markets. For all proprietary trademarks and third-party trademarks used by medin Medical Innovations GmbH see www.medin-medical.com/trademarks. © 2017 medin Medical Innovations GmbH. All rights reserved
Open the catalog to page 3All Medin Medical Innovations GmbH catalogs and technical brochures
-
Nuflow®
2 Pages
-
Pb_1000_long
3 Pages
-
PB_medinBLENDER_1093_1094
2 Pages
-
OP_heated_circuits_all_languages
24 Pages
-
OP_Nuflow_all_languages
127 Pages
-
OP_Medijet
103 Pages
-
Pb_4000_long
3 Pages
-
OP_Miniflow
103 Pages
-
OP Bubble
2 Pages
-
medin Company Brochure
16 Pages
-
Processing
4 Pages
-
Pb_20674X_short
2 Pages
-
Pb_20674X_long
3 Pages
-
Pb_1207_long
2 Pages
-
PB_1207MKI
2 Pages
-
PB_1207
2 Pages
-
OP_Blender_Rev09_all languages
115 Pages
-
Nuflow® Nasal cannula set
2 Pages
-
Promo Sheet Nuflow
2 Pages
-
Order Information Nuflow
2 Pages
-
OP_medinCNO_3090_REV12
68 Pages
-
OP Pediflow all languages
65 Pages
-
OP_medinCNOmini_3080_EN_Rev03
64 Pages
-
OP_medinSINDI_1080_REV14
36 Pages
-
Guideline_for_Transport_Rev06
20 Pages
Archived catalogs
-
medin Company Brochure
16 Pages
-
Flyer_medin_Rev04
2 Pages
-
Prospect_products_medin_Rev09
20 Pages
-
medinCNO®mini
4 Pages
-
MEDINsindi
2 Pages
-
Short_Application_Medijet_
2 Pages
-
Catalogue Pediflow®
4 Pages
-
Prospect_nasal_canula
4 Pages
-
Prospect_Miniflow_Bubble
4 Pages
-
Prospect_medinCNO
4 Pages
-
Medin_Catalog
16 Pages
-
Flyer_reuseable_bonnets
1 Pages
-
user_manual_medinSINDI
36 Pages
-
OP_Blender
18 Pages
-
OP_Circuits_heated
32 Pages
-
user_manual_medinCNO
59 Pages
-
OP_Miniflow_4000
96 Pages
-
OP_Medijet_1010_1020
4 Pages
-
OP_Medijet_1000
104 Pages
-
OP_Circuits_unheated
32 Pages
-
technical_data_medinSINDI
1 Pages
-
products_medin
16 Pages