medinCNO User Manual medical innovations The medinCNO contains batteries and electrical components. Consequently it cannot be disposed of in domestic waste but must be collected separately and recycled in accordance with local regulations. (WEEE) Classification (according to COUNCIL DIRECTIVE 93/42/EEC Annex IX): lib H Medin Medical Innovations GmbH A All Adam-GeiRler-Str. 1 - 82140 Olching - Germany ^^^^^H +49 8142-44846-0 - www.medinqmbh.com - info@medingmbh.com medical innovations medin Medical Innovations GmbH ■ Adam-Geisler-Str. 1 ■ D-82140 Olching

Open the catalog to page 2
user_manual_medinCNO - 3

medinCNO User Manual medin Medical Innovations GmbH Adam-Geisler-Str. 1 D-82140 Olching ℡+498142-448460 www.medingmbh.com info@medingmbh.com OP_cno Rev 04 Correct as of: 01.06.2014

Open the catalog to page 3
user_manual_medinCNO - 4

medinCNO User Manual medin Medical Innovations GmbH Adam-Geisler-Str. 1 D-82140 Olching ℡+498142-448460 www.medingmbh.com info@medingmbh.com OP_cno Rev 04 Correct as of: 01.06.2014

Open the catalog to page 4
user_manual_medinCNO - 5

medinCNO User Manual These instructions for use contain information about starting up, using and maintaining the medinCNO (medin-cno). They also contain safety information, describe the device's functions and give an overview of the ancillary equipment needed. Users must be very familiar with the information and warnings given in these instructions for use in order to operate the medinCNO safely. However, they are no substitute for training. The instructions and warnings are categorised as follows: Warning: Warnings must be followed in order to prevent possible serious consequences for the...

Open the catalog to page 5
user_manual_medinCNO - 6

medinCNO User Manual 2 Description of the Device and Conditions for Use 2.1 The medinCNO CPAP driver is used in combination with the Medijet nCPAP generator to administer CPAP therapy to premature infants and newborns. The medinCNO must be used under the supervision of expert, specially trained staff in a clinical setting, and the patient’s oxygen saturation must be monitored at the same time. Warning: - The medinCNO is intended for clinical use only. The medinCNO may only be used while the patient’s oxygen saturation is being monitored at the same time. The medinCNO may only be used by and...

Open the catalog to page 6
user_manual_medinCNO - 7

medinCNO User Manual Technical description of function The medinCNO is a CPAP driver that can be used in combination with the Medijet nCPAP generator to administer CPAP therapy. The role of the medinCNO in this CPAP system is to provide the ® necessary, possibly oxygen-enriched drive flow, which is fed to the nCPAP generator Medijet via the tubes connected to the patient and is converted into CPAP pressure within the generator. An internal electronic blender combines the air and oxygen coming from an external source and administers the total volume so that the drive flow reaching the...

Open the catalog to page 7
user_manual_medinCNO - 8

medinCNO User Manual Accuracy ± 3% (Vol.) MLF – 16 or OOM 102 measurement sensor Pressure measurement: Measurement range 0 mbar to 15 mbar - pressure graph Accuracy ±1.3 mbar Verification: Redundant measurement by two sensors Push (inspiration support by the medinCNO) Setting range additional flow during the inspiration push: Min: 0 L/min Max: 17.5 L/min minus set basic flow Duration 200 ms to 2 seconds Accuracy ± 1 L/min (if the total flow = basic flow + additional inspiration flow - is within the flow working range) ± 2 L/min (if the total flow = basic flow + additional inspiration flow -...

Open the catalog to page 8
user_manual_medinCNO - 9

medinCNO User Manual 3 Installation of the medinCNO – Conditions Prior to start-up, the medinCNO must be securely mounted. In doing so, the following conditions must be observed: Figure 3-1: a) Brackets holding the medinCNO in position; b) Ventilation slits; c) Overpressure valve; d) Knurled screws The medinCNO must always be securely mounted before the device is started up. To do this, the two fixing brackets on the back of the device (Figure 3-1-a) are inserted into a standard track (crosssection: 10 x 25 mm) and the brackets are then fixed in place manually using the knurled screws...

Open the catalog to page 9
user_manual_medinCNO - 10

medinCNO User Manual medical innovations The power supply unit (REF 39-113) of the medinCNO may only be connected to a power supply with • Voltage: 100 - 240V- (alternating current) • Strength of current: at least 1.1A The power supply unit of the medinCNO has a C8 connector for connection to the mains grid. The power line between the power supply unit of the medinCNO and the mains grid must therefore meet these conditions: • Power supply side: plug appropriate for the country • Device side: C7 plug in accordance with EN60320 • Minimum rated voltage: the minimum rated voltage of the power...

Open the catalog to page 10
user_manual_medinCNO - 11

medinCNO User Manual The charge status of the internal battery is displayed in the top left-hand area of the medinCNO screen (Figure 3-2). A full battery is shown with a symbol with five bars. As soon as only two bars remain, the battery symbol is shown in red and the medinCNO should be connected to the mains soon. As soon as there is only one bar left, the battery alarm is triggered. Attention: When the medinCNO is running on battery power, an alarm is sounded when the internal battery is low. If this happens it is essential that the device is connected to an external power source without...

Open the catalog to page 11
user_manual_medinCNO - 12

medinCNO User Manual H2O ≤ 870 ppm (V/V) and free from condensate. If as a result of the operating temperature it is possible that condensate may form despite a relatively low concentration of H2O in the air, then the concentration of H2O must be reduced accordingly. Figure 3-3: Water trap in the medinCNO air inlet; a) Bolt for removing the condensate from the water trap The medinCNO can be fitted with a water trap in the air inlet as an option (Figure 3-3) (REF 39-800). This allows small amounts of condensate to be removed from the air supply provided to the medinCNO if the water trap is...

Open the catalog to page 12
user_manual_medinCNO - 13

medinCNO User Manual External alarm The medinCNO has an interface for connection to an external alarm system. The interface can open or close an external current circuit in the event of an alarm. The interface thus acts only as a switch, that is, the power supply must be ensured by the external alarm system. Time Delay: The interface to the external alarm system is updated every 100 msec. That is, the alarm in the external alarm system is activated with a maximum delay of 100 msec in comparison to the alarm in the device. The alarm is likewise deactivated with a maximum delay of 100 msec in...

Open the catalog to page 13

All Medin Medical Innovations GmbH catalogs and technical brochures

  1. Nuflow®

    2 Pages

  2. Pb_1000_long

    3 Pages

  3. OP_Medijet

    103 Pages

  4. Pb_4000_long

    3 Pages

  5. OP_Miniflow

    103 Pages

  6. OP Bubble

    2 Pages

  7. Processing

    4 Pages

  8. Pb_1207_long

    2 Pages

  9. PB_1207MKI

    2 Pages

  10. PB_1207

    2 Pages

Archived catalogs

  1. MEDINsindi

    2 Pages

  2. Medin_Catalog

    16 Pages

  3. OP_Blender

    18 Pages

  4. OP_Medijet_1000

    104 Pages

  5. products_medin

    16 Pages