MELAquick 12+ p - 1

MELA  uick®12+ q Compact. Fast.  Str

Open the catalog to page 1
MELAquick 12+ p - 2

The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for “semicritical” use (restorative treatment) have to be prepared and treated after each patient, preferably in a validated, mechanised disinfection and cleaning process. If no mechanical prepa­ ation and treatment process is used, a manual process r can be selected, but it has to be concluded with sterilization of the instruments. “Critical” hand pieces and turbines used for paradontological, endodontic and surgical treatment have to be sterilized at the end of the...

Open the catalog to page 2
MELAquick 12+ p - 3

Example of loading with unwrapped instruments Example of loading with wrapped instruments High quality preparation­. Big inside — small outside. Both air removal and drying are of the utmost importance in the sterilization of handpieces and turbines. The fractionated gravity­ method creates the ideal conditions for sterilization safety in accordance­with European Standard 13060 — programs in line with the standard. Drying takes place by connecting the MELA quick®12+ to the compressed air supply of the practice in the preparation room. To protect the instruments and to preserve the value of...

Open the catalog to page 3
MELAquick 12+ p - 4

Operation — no compromises. Universal basket on a frame Small parts insert for universal basket All programs and options can be selected easily and quickly using the four soft keys found on the display. Support with ISO adapters on a frame The programs — fast and multifunctional. Three class S programs are provided : One Quick-Program for unwrapped instruments and two programs for wrapped instruments. All programs in accordance with the European Standard 13060. Programs Sterilization time Operating time* *Without drying and dependent on loading and installation conditions such as mains...

Open the catalog to page 4
MELAquick 12+ p - 5

Plug on the side for sterile filter (only in MELA quick®12+ p) Device fuse —10 AT Connection for monitoring the feed water container Connection for monitoring the waste water container Serial interface (RS232) for documentation Connection for compressed air (only in MELA quick®12+) Mains connection for IEC plug Connection for external waste water container Spring safety valve Slit for emergency unlocking Connection for external feed wa

Open the catalog to page 5
MELAquick 12+ p - 6

MELA  uick®12+ p q The stand-alone device. This innovative device concept can also be used if there is no compressed air connection in the preparation room. MELA quick®12+ p has a compressor pump integrated into the device, which permits operation of the autoclave irrespective of location. The functionality and short operating times are identical in both MELA quick®12+ devices. Documentation and approval. Possibilities for documentation, batch release and re-tracing known from the Pro- and PremiumClass MELAG device series are also available for the MELA quick®12+. Starting with MELA flash...

Open the catalog to page 6

All MELAG catalogs and technical brochures

  1. MELAseal

    9 Pages

  2. Pro-Line

    7 Pages

  3. MELAnet Box

    5 Pages

  4. MELAtherm®

    9 Pages

  5. MELAcontrol

    5 Pages

  6. MELAdoc

    5 Pages

  7. MELAstore

    3 Pages

  8. MELAcontrol

    5 Pages

  9. MELAdem®

    8 Pages

  10. MELAdem 40

    2 Pages

  11. MELAtherm 10

    12 Pages

  12. EUROKLAV +

    12 Pages

  13. S-Class

    12 Pages

  14. Profi-Class

    12 Pages

  15. MELAdem®40

    2 Pages

Archived catalogs

  1. Vacuklav 40 B+

    12 Pages

  2. MELAseal Pro

    4 Pages

  3. Cliniklav®25

    12 Pages