video corpo

VCA (ASTRAGALIC CONICAL SCREW)
2Pages

{{requestButtons}}

Catalog excerpts

VCA (ASTRAGALIC CONICAL SCREW) - 1

Vca - Stainless steel CODE Sterile Astragalic Screw Ø 8x30mm Sterile Astragalic Screw Ø 8x35mm Sterile Astragalic Screw Ø 8x40mm Sterile Astragalic Screw Ø 8x45mm Sterile Astragalic Screw Ø 6,5x25mm Sterile Astragalic Screw Ø 6,5x30mm Sterile Astragalic Screw Ø 6,5x35mm Vca - Bored stainless steel Astragalic Conical Screw Sterile Astragalic Bored Screw Ø 8x30mm Sterile Astragalic Bored Screw Ø 8x35mm Sterile Astragalic Bored Screw Ø 8x40mm Sterile Astragalic Bored Screw Ø 8x45mm Sterile Astragalic Bored Screw Ø 6,5x25mm Sterile Astragalic Bored Screw Ø 6,5x30mm Sterile Astragalic Bored Screw Ø 6,5x35mm Sterile Astragalic Titanium Screw Ø 8x30mm Sterile Astragalic Titanium Screw Ø 8x35mm Sterile Astragalic Titanium Screw Ø 8x40mm Sterile Astragalic Titanium Screw Ø 8x45mm Sterile Astragalic Titanium Screw Ø 6,5x25mm Sterile Astragalic Titanium Screw Ø 6,5x30mm Sterile Astragalic Titanium Screw Ø 6,5x35mm DESCRIPTION Screwdriver for astragalic screw Heavy punch for astragalic screw The VCA screws are supplied sterile, as indicated on the label. For the instruments, autoclave sterilization (saturated steam) with the following guidelines is recommended: Temperature: 135° Mikai does not recommend using EtO or other cold sterilization methods. We thank Dr. Mauro Di Stadio for his cooperation Headquarters: Via P. Gobetti 56r – 16145 Genova Tel. +39 010 30801 – Fax. +39 010 3080211 www.mikai.it – servizio.clienti@mikai.it Manufacturing Facility: Via Canestrello 2 – 36050 Monteviale (VI) Tel. +39 0444 950100 – Fax. +39 0444 950133 www.mikai.it – servizio.clienti@mikai.it VCA 0476 2012© Copyrights MIKAI S.p.A. P.IVA 00972790109 - All rights reserved 2012 © Copyrights MIKAI S.p.A. - All rights reserved

Open the catalog to page 1
VCA (ASTRAGALIC CONICAL SCREW) - 2

Astragalic Conical Screw Surgical technique Advantages Easy introduction As the VCA screw is inserted into the talus there is no peroneal malleolus obstruction present when it is inserted into the heel. Raising and lateralization The screw tapering has a biomechanical advantage that in addition to lowering the talus also lateralizes. Intact endo sinus tarsi structures The VCA performs an exo sinus tarsi arthrosis and therefore, all the structures within the sinus tarsi are left intact which would instead be involved in an endo sinus tarsi arthrosis. Easy to remouve Even in presence of...

Open the catalog to page 2

All MIKAI catalogs and technical brochures

  1. MINISTYLO

    8 Pages

  2. CLICKIT CF

    23 Pages

  3. SMART SYSTEM

    2 Pages

  4. BLUE SHARK

    2 Pages

Archived catalogs