FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE
8Pages

{{requestButtons}}

Catalog excerpts

FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 1

FOOTMOTION PL ATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE Precontoured implants Hexalobe screw recess design Transfixation screw

Open the catalog to page 1
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 2

FO OT M OT I O N P L AT IN G S Y ST EM - M T P Indications: The Footmotion Plating System is intended for arthrodeses, fractures and osteotomies fixation and revision surgeries of the foot in adults. Contra-indications: • Severe vascular damage, bone devitalisation. • Pregnancy. • Acute or chronic, local or systemic infections. • Lack of musculo-cutaneous cover, severe vascular deficiencies affecting the focus. • Bone deterioration impeding proper fixation of the screws in the bone. • Muscular deficit, neurological deficiency, or behavioural disorders that could result in abnormal...

Open the catalog to page 2
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 3

FIX ATIO N - T ECHNICA L FE AT UR ES FIXATION AND SCR EW FE ATURES • A single screw diameter: Ø2.8 mm. Both locking (SLT2.8Lxx) and non locking screws (RLT2.8Lxx) are available. • The screw head is minimally invasive and buried in the plate (1) so as to limit the risk of soft tissue irritation. Ø2.8 mm locking screw (SLT2.8Lxx) Ø2.8 mm non locking screw (RLT2.8Lxx) Hexalobe screw recess design • The hexalobe screw recess design improves torque transmission and ability to cope with difficulty arising from screw insertion into the bone. MONOAXI A L SELF -LOCKING SYSTEM Features: • he T...

Open the catalog to page 3
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 4

S U R GI C A L T ECHNI Q U E JOINT SUR FA CES PR EPA R ATION 1. 1. Dislocate the joint so as to expose the head of the first metatarsal and the base of the proximal phalanx. 2. Insert the Ø1.6 mm pin (33.0216.150) through the head of the first metatarsal into the medullary cavity. To determine the appropriate reaming size, insert the convex reamers successively along the pin. Progressively, reduce the diameter until the cartilage surfaces have been removed. Remove the reamer and pin. 3. Expose the base of the phalanx and insert the Ø1.6 mm pin (33.0216.100) so as to achieve proper alignment...

Open the catalog to page 4
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 5

S U R GI C A L T ECHNI Q U E P OSITIONING OF THE PLATE 5. PLATE BENDING The plates of the Footmotion Plating System can be bent using the appropriate bending pliers (ANC578) and complying with the following instructions: 5. Position the joint in the desired direction and stabilize it using a Ø1.6 mm pin (33.0216.150). 6. Choose the plate corresponding to the desired correction (three sizes available). NB: The plates of the Footmotion Plating System are precontoured. If necessary, they can be bent to be adapted to the arthrodesis to perform. - ending is only possible in the areas B intended...

Open the catalog to page 5
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 6

S U R GI C A L T ECHNI Q U E COMPRESSION OF THE JOINT OPTION 1: COMPRESSION USING THE RAMP OBLONG HOLE 1 1.a 11.a) Drill (ANC590) into the most proximal part of the ramp oblong hole, and directly read the depth on the non-threaded bent guide gauge (ANC586). 11.b) Insert a Ø2.8 mm non locking screw (RLT2.8Lxx) then perform compression using the screwdriver (ANC575) (see § “Ramp oblong hole”). 11.c) Insert in the proximal part, the two Ø2.8 mm locking screws (SLT2.8Lxx) into the remaining holes following the steps 8 & 9. Finalize by inserting a Ø2.8 mm non locking screw (RLT2.8Lxx) into the...

Open the catalog to page 6
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 7

* Green anodized Golden anodized

Open the catalog to page 7
FOOTMOTION PLATING SYSTEM - MTP FIRST METATARSO-PHALANGEAL ARTHRODESIS PLATE - 8

FOOTMOTION PLATING SYSTEM - MTP - INSTRUMENTS Ref. Description Qty ANC350 04.5 mm AO quick coupling handle - Size 1 2 ANC576 02.0 mm threaded guide gauge for 02.8 mm screws 2 ANC586 02.0 mm non threaded bent guide gauge for 02.8 mm screws 1 BASE (ANC648/B) INSERT SCREW RACK REMOVAL KIT If you have to remove FOOTMOTION PLATING SYSTEM - MTP implants, make sure to order the Newclip Technics removal set which includes the following instruments: - ANC575: T8 quick coupling screwdriver - ANC350: 04.5 mm AO quick coupling handle - Size 1 This instrumentation is...

Open the catalog to page 8

All Newclip Technics catalogs and technical brochures

  1. INITIAL C™

    12 Pages

  2. PERIACTIV

    3 Pages

  3. Single Use kit

    12 Pages

  4. NATIV

    2 Pages

  5. ATLANTIC OW

    6 Pages

  6. ATLANTIC CW

    6 Pages

  7. FLATFOOT

    2 Pages

  8. Activ Ankle

    8 Pages

  9. ALIANS ULNA

    8 Pages

  10. FOREFOOT

    8 Pages

  11. ACTIVMOTION

    8 Pages

  12. INITIAL R

    8 Pages

  13. KEMIS

    4 Pages

  14. ALIANS ELBOW

    8 Pages