iCare + - 3

CLEANS, DISINFECTS AND LUBRICATES 4 INSTRUMENTS ADVANTAGES • • • • Simplicity Automatic Speed C onstant monitoring of working parameters for consistent performance Universal connection of dynamic instruments Validation Traceability D etects instrument type spray/water external or internal • Consistent repetition of cycles FOR PERFECT TREATMENT Manual cleaning of instruments does not remove all deposits and residues. Dynamic instruments that are poorly maintained or not adequately cleaned may become damaged and pass on infections to both patients and practitioners. IN-DEPTH RESEARCH AND...

Open the catalog to page 3
iCare + - 4

INTELLIGENCE AT THE SERVICE OF YOUR INSTRUMENTS iCare+ is smart and detects the type of instrument attached to the ports (internal/external spray or without spray) when canals are blocked or the wrong cycle has been selected for a specific instrument to ensure cycle efficiency. INTERNAL / EXTERNAL Drive air Spray water Spray water During the different cycles, iCare+ starts the rotation of instruments and injection of treatment products into all the internal mechanisms and tubing of the instruments to provide deep cleaning and disinfection; a pressure spray simultaneously cleans and...

Open the catalog to page 4
iCare + - 5

CLEANING AND DISINFECTION Bacteriostatic TWO PRODUCTS INEXTRICABLY LINKED TO iCare+ iCare+ working hand in hand with n.clean and n.cid products. n.clean and n.cid have been specifically developed for rotary instruments in compliance with laboratory protocols as well European and International standards. VALIDATED ASSOCIATION OF CERTIFIED PRODUCTS Extensive laboratory tests have been conducted on NSK turbines, handpieces and contra-angles, as well as on instruments from other brands: the results are identical for all tested instruments and always in compliance with EN ISO15883 and EN ISO...

Open the catalog to page 5
iCare + - 6

EFFECTIVENESS FOR SAFETY OF PATIENTS COMPLIANT WITH EUROPEAN STANDARDS Treatment cycle validation: iCare+ comes equipped with an integrated processor enabling it to check in real time that the various internal components are moving the cleaning and disinfection solutions according to the requirements of the laboratory protocols (EN ISO 15883 and EN ISO 15883-5 standards) which are applicable in all countries of the European Union. SECURITY Tests performed by the Dr Brill and Microsept Institutes conducted on extremely dirty instruments (containing sheep’s blood with heparine, protamine,...

Open the catalog to page 6
iCare + - 7

COMPLETE TRACEABILITY INTERNAL TRACEABILITY SOFTWARE In addition to the permanent internal validation process software is available to log all cycle data on an external device. iCare+ generates a serial number for every cycles. Once the data has been transfered to a computer you can add serial numbers of individual instruments to specific cycle records in order to establish total traceability. DATA STORAGE To allow traceability and external storage of the iCare+ cycle data an easily accessible USB port is built into iCare+ unit. USER-FRIENDLY INTERFACE The user friendly software interface...

Open the catalog to page 7
iCare + - 8

PLUG AND PLAY! QUICK INSTALLATION All that is required is an electrical and an air supply. Connection to the water or draining system is not required. No need for connection to water supply or drainage system. EASY TO USE The clearly and intuitively arranged control panel together with the LED indicators and the internally lit treatment chamber makes it really easy to operate iCare+ the treatment chamber: • yellow for cleaning • white for disinfection • blue for lubrication • When the green LED lights up at the end of the cycle, the operator knows that the cycle has been completed correctly...

Open the catalog to page 8
iCare + - 9

Only electrical and air supply required! iCare+ cleans, disinfects and lubricates the rotary instruments automatically iCare+ treats up to 4 dynamic instruments in 15 minutes! 3 possible programs: Optimum, General, Basic CONSTANT CONTROL OF PARAMETERS ? he combination of iCare+ with n.clean and n.cid has been fine T tuned for perfect results: n.clean and n.cid have been specially formulated and validated to meet all applicable European and International Standards effect and validated in laboratories UNIVERSAL CONNECTIONS? VALIDATION? iCare+ guarantees that the cycle is consistently...

Open the catalog to page 9
iCare + - 10

ACCCESSORIES AND TECHNICAL SPECIFICATION Starter Pack (6 bottles of n.clean, 6 bottles of^n.cid^^l^bqttJ^o^Oil TECHNICAL CHARACTERISTICS

Open the catalog to page 10

All NSK catalogs and technical brochures

  1. Osseo 100+

    2 Pages

  2. Volvere i7

    2 Pages

  3. VIVA ace

    6 Pages

  4. NLX nano

    2 Pages

  5. Oral Surgery

    18 Pages

  6. Pana Max2

    2 Pages

Archived catalogs

  1. Dentalone

    5 Pages

  2. Ipex II

    2 Pages

  3. varios_series

    12 Pages

  4. ultimate_xl

    2 Pages

  5. ISD900

    2 Pages

  6. Osseo 100

    2 Pages

  7. Pana-Max

    2 Pages

  8. Ti-Max S970

    8 Pages

  9. iClave

    8 Pages

  10. Variosurg 3

    24 Pages

  11. Varios series

    12 Pages

  12. iCare

    4 Pages

  13. nano series

    2 Pages