video corpo

Osseo 100
2Pages

{{requestButtons}}

Catalog excerpts

Osseo 100 - 1

1. The MulTipeg™ is attached to the implant. It screws effortlessly into the implant’s internal threads. (approximately 6-8 Ncm of torque). 2. Just aim for the magnet on top of the MulTipeg™. Non-invasive, objective, accurate and repeatable. The peg is excited by magnetic pulses and vibrates due to the stiffness in the contact area between the bone and the implant surface. 3. An ISQ value is generated and shown on the display. This reflects the level of stability on the universal ISQ scale – from 1 to 99. The higher the ISQ value, the more stable the implant. Osseointegration Monitoring Device About ISQ The below is not a clinical recommendation from NSK. Decreasing micro mobility with increasing ISQ values ISQ Value More time required for implant osseo-integration 70 ISQ values measured for one or two stage full or partial cases ISQ values measured for single tooth one stage and/or immediate loading cases 1. Sennerby L Prof., Implantologie 2013; 21(1): 21-23 2. Kokovic V, Jung R, Feloutzis A, Todovoric V, Jurisic M, Hämmerle C. Clinical Oral Implants Research, 00, 2013, 1-6 3. M Bornstein, C Hart, S Halbritter, D Morton, D Buser, Prof. Dr. med. dent. Clin Implant Dent Relat Res 2009 4. Serge Baltayan, Joan Pi-Anfruns, Tara Aghaloo, Peter Moy. J Oral Maxillofac Surg 74:1145-1152, 2016 5. P O Östman, Private practitioner, Falun- and Biomaterial Group, Sahlgrenska Academy Gothenburg. Clinical Implant Dentistry and Related Research, Volume 7, Supplement 1, 2015 6. Daniel Rodrigo, Luis Aracil, Conchita Martin, Mariano Sanz. Clin. Oral Impl. Res. 21, 2010; 255-261 7. Pagliani L, Sennerby L, Petersson A, Verrocchi D, Volpe S & Andersson P. Journal of Oral Rehabilitation 2012 8. P Trisi Phd, T Carlesi DDS, M Colagiovanni DDS, G Perfetti MD, DDS. Journal of Osteology and Biomaterials, Volume 1, Number 3, 2010 9. S Hicklin, E Schneebeli, V Chappuis, S Francesco, M Janner, D Buser, U Brägger. Clin. Oral Impl. Res. 00, 2015; 1-9 10. L. Milillo, C. Fiandaca, F. Giannoulis, L. Ottria, A. Lucchese, F. Silvestre, M. Petruzzi. Oral & Implantology - anno IX - n. 3/2016

Open the catalog to page 1
Osseo 100 - 2

Osseo 100 measure implant stability and osseointegration to enhance decisions about when to load the implant. Especially important when using protocols with shorter treatment time and treating higher risk patients. The uncomplicated operation that measures ISQ allows the implant loading period to be planned in advance. The reconstruction of crowns and bridges can be predicted to decrease the risk for failures. Measurements can be made without unnecessary impact since the equipment does not come into physical contact with the implant or abutment. REUSABLE MulTipeg™ • For all major implant...

Open the catalog to page 2

All NSK catalogs and technical brochures

  1. Osseo 100+

    2 Pages

  2. Volvere i7

    2 Pages

  3. VIVA ace

    6 Pages

  4. NLX nano

    2 Pages

  5. Oral Surgery

    18 Pages

  6. Pana Max2

    2 Pages

Archived catalogs

  1. Dentalone

    5 Pages

  2. Ipex II

    2 Pages

  3. varios_series

    12 Pages

  4. ultimate_xl

    2 Pages

  5. ISD900

    2 Pages

  6. Pana-Max

    2 Pages

  7. Ti-Max S970

    8 Pages

  8. iClave

    8 Pages

  9. Variosurg 3

    24 Pages

  10. iCare +

    10 Pages

  11. Varios series

    12 Pages

  12. iCare

    4 Pages

  13. nano series

    2 Pages