Osseo 100 - 2 Pages

Add to MyMedicalExpo favorites
Osseo 100

Catalog excerpts

1. The MulTipeg™ is attached to the implant. It screws effortlessly into the implant’s internal threads. (approximately 6-8 Ncm of torque). 2. Just aim for the magnet on top of the MulTipeg™. Non-invasive, objective, accurate and repeatable. The peg is excited by magnetic pulses and vibrates due to the stiffness in the contact area between the bone and the implant surface. 3. An ISQ value is generated and shown on the display. This reflects the level of stability on the universal ISQ scale – from 1 to 99. The higher the ISQ value, the more stable the implant. Osseointegration Monitoring Device About ISQ The below is not a clinical recommendation from NSK. Decreasing micro mobility with increasing ISQ values ISQ Value More time required for implant osseo-integration 70 ISQ values measured for one or two stage full or partial cases ISQ values measured for single tooth one stage and/or immediate loading cases 1. Sennerby L Prof., Implantologie 2013; 21(1): 21-23 2. Kokovic V, Jung R, Feloutzis A, Todovoric V, Jurisic M, Hämmerle C. Clinical Oral Implants Research, 00, 2013, 1-6 3. M Bornstein, C Hart, S Halbritter, D Morton, D Buser, Prof. Dr. med. dent. Clin Implant Dent Relat Res 2009 4. Serge Baltayan, Joan Pi-Anfruns, Tara Aghaloo, Peter Moy. J Oral Maxillofac Surg 74:1145-1152, 2016 5. P O Östman, Private practitioner, Falun- and Biomaterial Group, Sahlgrenska Academy Gothenburg. Clinical Implant Dentistry and Related Research, Volume 7, Supplement 1, 2015 6. Daniel Rodrigo, Luis Aracil, Conchita Martin, Mariano Sanz. Clin. Oral Impl. Res. 21, 2010; 255-261 7. Pagliani L, Sennerby L, Petersson A, Verrocchi D, Volpe S & Andersson P. Journal of Oral Rehabilitation 2012 8. P Trisi Phd, T Carlesi DDS, M Colagiovanni DDS, G Perfetti MD, DDS. Journal of Osteology and Biomaterials, Volume 1, Number 3, 2010 9. S Hicklin, E Schneebeli, V Chappuis, S Francesco, M Janner, D Buser, U Brägger. Clin. Oral Impl. Res. 00, 2015; 1-9 10. L. Milillo, C. Fiandaca, F. Giannoulis, L. Ottria, A. Lucchese, F. Silvestre, M. Petruzzi. Oral & Implantology - anno IX - n. 3/2016

 Open the catalog to page 1

Osseo 100 measure implant stability and osseointegration to enhance decisions about when to load the implant. Especially important when using protocols with shorter treatment time and treating higher risk patients. The uncomplicated operation that measures ISQ allows the implant loading period to be planned in advance. The reconstruction of crowns and bridges can be predicted to decrease the risk for failures. Measurements can be made without unnecessary impact since the equipment does not come into physical contact with the implant or abutment. REUSABLE MulTipeg™ • For all major implant...

 Open the catalog to page 2

All NSK catalogs and technical brochures

  1. Dentalone

    5 Pages

  2. M40 XS

    2 Pages

  3. Ipex II

    2 Pages

  4. varios_series

    12 Pages

  5. ultimate_xl

    2 Pages

  6. Ti MAX Z-SG 45

    2 Pages

  7. ISD900

    2 Pages

  8. S-Max M series

    6 Pages

  9. VIVA ace

    6 Pages

  10. NLX nano

    2 Pages

  11. Ti-Max Z45L

    4 Pages

  12. Pana-Max

    2 Pages

  13. Dentalone

    5 Pages

  14. General Catalog

    153 Pages

  15. Oral Surgery

    18 Pages

  16. Ti-Max Z Series

    12 Pages

  17. Ti-Max Z-SG45

    2 Pages

  18. VOLVERE i7

    2 Pages

  19. Ti-Max S970

    8 Pages

  20. iClave

    8 Pages

  21. Pana Max2

    2 Pages

  22. Variosurg 3

    24 Pages

  23. iCare +

    10 Pages

  24. Varios series

    12 Pages

  25. iCare

    4 Pages

  26. nano series

    2 Pages

Archived catalogs

  1. N1 clave

    14 Pages