Endometrial sampling set-The Curette
2Pages

{{requestButtons}}

Catalog excerpts

Endometrial sampling set-The Curette - 1

The Curette Panpac Medical Corporation 6F-2, No. 202, Sec. 3, Ta-Tong Road, Shi-Chih District, New Taipei City, Taiwan. TEL : 886-2-86472242 FAX : 886-2-86472770 The ETO Sterilized Curette is used to obtain a sample of differentiated endometrial tissue. The Curette is a 3mm (O.D.) endometrial suction curette with a Randall-like cutting edge at its distal end and packaged with a twist-and-lock syringe. The syringe provides the vacuum or suction during the procedure. The Curette is sterile unless the package is opened or damaged. It is designed for single patient use only. INDICATION The endometrial suction curette- The Curette is a device used to remove samples of materials from the uterus and from the mucosal lining of the uterus by scraping or vacuum suction. These devices obtain tissue samples for purposes of biopsy precancer screening or they can be used for menstrual extraction. CAUTION Federal law restricts this device to sale by or on the order of a physician. Do not reuse for avoiding user may be infected by the microorganism. The procedure is contraindicated in suspected pregnancy or in women with acute pelvic inflammatory disease. It is also contraindicated in women with chronic cervical infections or any conditions which contraindicate an outpatient surgical procedure. While sounding the uterus and using this device, care should be taken to avoid perforation of the uterine wall. Do not depress the syringe’s piston while it is in the uterus. DIRECTIONS FOR USE 1. Prepare the vagina and cervix as you would for any sterile intrauterine procedure. 2. Expose the cervix using a suitable speculum.

Open the catalog to page 1
Endometrial sampling set-The Curette - 2

3. Gently insert a uterine sound to determine the depth and direction of the uterine cavity. It may be necessary to grasp the cervix with a tenaculum. If the uterus is anteverted, the grasp should be on the anterior lip of the cervix. If the uterus is retroverted, the grasp should be on the posterior lip of the cervix. Apply gentle traction to straighten any cervical curvature. 9. Cut off the tip of the Curette just above the sampling point of the device. The sampling point is the entrance port with the Randall-like cutting edge at the distal end of the Curette. Unlock the syringe by...

Open the catalog to page 2

All Panpac Medical catalogs and technical brochures

  1. TheCurette

    2 Pages

  2. RigidCurette

    1 Pages

  3. HSGCatherSet

    1 Pages

  4. Bellota

    1 Pages

  5. UterineSound

    1 Pages