RX Daytona Plus - 22 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

Catalogue excerpts

RX DAYTONA+ A FULLY AUTOMATED CLINICAL CHEMISTRY ANALYSER WITH A COMBINED THROUGHPUT OF 450 TESTS PER HOUR

 Open the catalogue to page 1

HIGH QUALITY TESTING ON A COMPACT EASY TO USE CLINICAL CHEMISTRY ANALYSER FOR ACCURATE RESULTS YOU CAN TRUST

 Open the catalogue to page 2

04 SYSTEM OVERVIEW 05 TEST MENU 09 SOFTWARE ||    FEATURES AT A GLANCE |2 ORDERING INFORMATION 13 SPECIFICATIONS 15 THE RX SERIES RANDOX - A GLOBAL DIAGNOSTIC SOLUTIONS PROVIDER

 Open the catalogue to page 3

The RX daytona+ is a bench-top, fully automated, random access clinical chemistry analyser capable of performing routine & specialised testing and emergency STAT sampling. The most versatile analyser in its class, the RX daytona+ combines robust hardware and intuitive software with the world leading RX series test menu for unrivalled performance. The RX daytona+ is capable of 270 photometric tests per hour and up to 450 including ISE. TEST MENU & CONSOLIDATION Expand your testing capabilities on one efficient platformAchieve accurate patient results first time, every time Reliability ensures no...

 Open the catalogue to page 4

QUALITY CONTROL FLEXIBILITY & VERSATILITY SAVINGS    V Developed to improve confidence in your results Increased functionality maximises testing capabilities Smart technology designed to avoid additional costs Generation of Levey-Jennings charts, calibration curves and QC statistics for reliable results. Users can view QC history. There are 7 different calibration options available including; Factor, Linear, Point to point, Log-logit, Exponential, Spline and Spline 2. Unrivalled QC capabilities puts patient safety at the centre of your laboratory. 12 wavelengths generated via diffraction grating...

 Open the catalogue to page 5

SYSTEM OVERVIEW REAGENT CAROUSEL 50 reagent positions for 70ml & 20ml bottles, all cooled between 8-15°C. Automatic barcode identification ensures smooth recognition of reagents. Dedicated reagents are available from Randox. CUVETTES 72 semi-permanent reaction cuvettes lasting for 3-6 months. On-board cuvette checking function ensures only clean and viable reaction vessels are used. WASH STATION A thorough 12 stage washing process with acid, alkali and pure water wash steps. Liquid level sensors at stations 1-5 prevent cuvette overflows. SAMPLE CAROUSEL 50 positions are contained within the universal...

 Open the catalogue to page 7

CLINICAL AUTOIMMUNE: Complement Component 3 Complement Component 4 CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity IgA IgE IgG IgM Rheumatoid Factor BASIC METABOLIC PROFILE: Calcium CO2 Total Chloride Creatinine Glucose Potassium Sodium Urea BONE PROFILE: Alkaline Phosphatase Calcium Phosphorus Total Protein CARDIAC: Cholesterol CK-MB CK-NAC CRP CRP Full Range (0.3-160mg/l) CRP High Sensitivity Digoxin Direct HDL Cholesterol Direct LDL Cholesterol HDL3 H-FABP Homocysteine Lipoprotein (a) Myoglobin sLDL Triglycerides TxB Cardio COMPREHENSIVE METABOLIC PROFILE: Albumin Alkaline Phosphatase ALT AST...

 Open the catalogue to page 8

Albumin Alkaline phosphatase ALT (GPT) Aldolase Ammonia Amylase AST (GOT) Bile acids Bilirubin Calcium Chloride Cholesterol Cholinesterase (Butyryl) CK-NAC CO2 Total Copper Creatinine Canine CRP CRP Fructosamine Gamma-GT GLDH Glucose Glycerol HDL Iron (UIBC) Lactate Lactate dehydrogenase LDL Lipase Magnesium NEFA (Non-esterified fatty acids) Phosphorus (Inorganic) Potassium Ranbut (Hydroxybutyrate) Ransel (Glutathione peroxidase) Ransod (Superoxide dismutase) Sodium Total Protein Triglycerides Urea Uric Acid Urinary protein Zinc THERAPEUTIC DRUGS: Acetaminophen Carbamazepine Digoxin Gentamicin Lithium Phenobarbitol...

 Open the catalogue to page 9

Acetaminophen Acetic Acid Acid phosphatase Adiponectin Albumin Aldolase Alkaline Phosphatase Alpha-1 Acid Glycoprotein Alpha-1 Antitrypsin ALT (GPT) Ammonia Amphetamines Amylase Apolipoprotein A-1 Apolipoprotein AII Apolipoprotein B Apolipoprotein CII Apolipoprotein CIII Apolipoprotein E ASO AST (GOT) Barbiturates Benzodiazepines Beta-2 Microglobulin Bile Acids Bilirubin (Direct & Total) Calcium Canine CRP Cannabinoids Carbamazepine Ceruloplasmin Chloride (Non-Direct) Cholesterol Cholinesterase (Butyryl) CK-MB CK-NAC CO2 Total Cocaine metabolite Complement Component 3 Complement Component 4 Copper Creatinine CRP CRP...

 Open the catalogue to page 10

SOFTWARE The RX daytona+ utilises familiar Windows® based software and easily recognisable icons making it appealing and easy-to-use for all staff involved in its operation. Straightforward operation of the software results in minimal training requirements and enhanced productivity. The superior functionality of the quality control software generates Levey-Jennings charts, calibration curves and QC statistics for reliable patient results. LIMS (Laboratory Information Management System) connectivity is easily achievable via ASTM standard. CHEMISTRY PARAMETERS The operator can easily search for previous...

 Open the catalogue to page 12

The operator is instructed via easy to follow steps The run monitor displays full patient demographics. on how to carry out daily, weekly and monthly maintenance. This screen indicates the number of tests and time left until Daily maintenance takes only 5 minutes to do. The analyser has completion. The operator may also add emergency STAT a countdown timer to show when routine servicing is due. samples from this screen. QUALITY CONTROL The QC screen generates Levey-Jennings charts and calibration The software displays the current valid calibration for each curves for a visual performance assessment,...

 Open the catalogue to page 13

Low water consumption of just 5 litres per hour Unique emergency loading port allows STAT samples to be analysed quickly and easily during runs Automatic wake and sleep mode plus pre-programmable 11 instrument preparation Dual 5 speed stirrers optimised for each chemistry reaction Clot detection sensor recognises clots such as fibrin at the sample pipette so that only acceptable samples are tested Reagent micropipette with liquid level sensor and crash detection alerts operator to follow troubleshooting steps

 Open the catalogue to page 14

In choosing to purchase the RX daytona+ from Randox you are partnering with a company that has over 35 years' experience in the IVD industry and clinical chemistry analyser placements in over 120 countries worldwide. Every customers needs are different and Randox sales staff and distributor partners will work with your laboratory to create a bespoke package to suit your requirements. Randox Laboratories provide customers with an unrivalled technical support service. ORDERING INFORMATION RX daytona+ with ISE For more information contact your local representative, or email us at:

 Open the catalogue to page 15

All Randox Laboratories catalogues and technical brochures

  1. Antioxidants LT086

    16 Pages

    En
  2. RX misano

    20 Pages

    En
  3. Rx Imola

    22 Pages

    En
  4. RX Monaco

    22 Pages

    En
  5. ADIPONECTIN

    16 Pages

    En
  6. REAGENTS

    64 Pages

    En
  7. Preparing QC

    1 Pages

    En
  8. Acusera 24•7

    28 Pages

    En
  9. RX modena

    22 Pages

    En
  10. RX Series

    13 Pages

    En
  11. Linearity sets

    16 Pages

    En
  12. 2017 Product List

    92 Pages

    En
  13. Evidence

    16 Pages

    En
  14. Acusera

    132 Pages

    En
  15. Evidence Evolution

    16 Pages

    En
  16. Carbon Dioxide

    2 Pages

    En
  17. Thyroid Arrays

    4 Pages

    En
  18. Cerebral Arrays

    4 Pages

    En
  19. Endocrine Array

    4 Pages

    En
  20. Rx Daytona

    16 Pages

    En

Archived catalogues

  1. RIQAS Explained

    36 Pages

    En
  2. Molecular Testing

    16 Pages

    En
  3. Fertility Array

    4 Pages

    En
  4. Evidence

    16 Pages

    En