Catalog excerpts
Imagine... automated onboard disinfection... residue free
Open the catalog to page 1Redefining state-of-the-art... The next generation of excellence is here. • enu-driven software, all-digital control M In 3 different configurations to meet your • 2 configurable Cryobar® positions 1 - Round specimen holders in 3 sizes - ound biopsy and standard Cryomold® R positions offer standardised specimen orientation - ryo+® area cools to -20°C below chamber C temperature; down to -50°C laboratory needs. Select automated disinfection. Or motorised sectioning. Or both. But no matter which model of the Tissue-Tek® Cryo3® you choose, you’ll also benefit from time-proven features,...
Open the catalog to page 2Smooth precision, reliable performance • all-bearing microtome, computer-controlled B • otorised advance/retract with limit M protection • asy-to-use anti-roll rake or anti-roll plate: E specimen transfer to the slide • anual or optional motorised trimming M and sectioning • lade holder accepts both Accu-Edge® B low-profile and high-profile disposable blades • aintenance-free microtome located M outside the chamber Simple to operate, yet sophisticated • reconfigured memory settings for: P specimen type procedure operator • treamlined, all-digital S control panels; multilingual
Open the catalog to page 3Easily programmed setup menu • isinfection: automatic cycle every day D or on demand • efrost: automatic cycle every day D or on demand • hamber temperature: 0°C to -35°C ±1°C C • ection thickness: 1 µm to 99 µm ±1 µm S • ection counter mode: sections S or thickness • rim thickness: 1 µm to 200 µm ±1 µm T • ntermittent sectioning: 1 to 99 ±1 section; I or total thickness: 1 µm to 99 µm ±1 µm Easily orient specimen with Tissue-Tek® O.C.T.™ Compound using the Cryomold® technique. The heat extractor can be used to enhance freezing. • etract/advance speed: 500 µm/sec R or 800 µm/sec •...
Open the catalog to page 4Fluid-free, waste-free disinfection Innovative ozone disinfection designed for maximum safety in routine operation • isinfection performed within 75 minutes D • bort sequence takes less than 15 minutes A • efrost cycle not required prior to initiating D disinfection cycle • o residue inside chamber: by-product is O2 N Password-secure chamber access • hamber window is interlocked and sealed C until all ozone is catalysed into oxygen • hamber also can be locked at any time to C minimize accidental exposure to pathogens Vacuum debris removal system Practical, easy removal of excess debris and...
Open the catalog to page 5Dedicated to Histopathology Sakura Finetek, again, improves the laboratory. By offering a flexible, high precision instrument, the users can conveniently complete their activities in a safe environment. As the innovative company in histopathology, Sakura Finetek is continuously looking for possibilities to improve the laboratory... and succeeds in offering a solution for the problems found in the histopathology laboratory. Product Specifications Dimensions (W x D x H) Weight Chamber Temperature Range -35°C to 0°C Cryobar® Temperature -50°C minimum (Cryo+® section) Sectioning Speed Range:...