video corpo

CBC II
2Pages

{{requestButtons}}

Catalog excerpts

CBC II - 1

ConstaVac™ Closed System Study Supports Benefits of Postoperative Salvage Blood Blood Conservation System Blood Conservation System Excerpts From: Autologous Blood Transfusion After Total Knee Arthroplasty A Randomized, Prospective Study Comparing Predonated and Postoperative Salvage Blood “The need for the surgeon to schedule patients for blood predonation, delaying the procedure, and the inconvenience for patients to travel to the blood bank and take oral iron or erythropoietin would be eliminated by the use of postoperative blood salvage.” 1. “The average preoperative hematocrit was significantly lower in patients who predonated autologous blood than in patients in the study group.” 1. “This study demonstrated that autologous blood from unwashed postoperative salvage from the drain was as effective in preventing the need for allogeneic blood as 1 unit of predonated autologous blood in patients undergoing primary TKA or revision procedures…” 1. CBCII CBCII CBCII CBCII CBCII Conservation Kit with 1/8” Round PVC Wound Drain Conservation Kit with 1/4” Round PVC Wound Drain Conservation Kit with 3/16” Round PVC Wound Drain Collection Only Kit with 1/8” Round PVC Wound Drain Blood Conservation Reservoir Only (drain not included) CBCII Blood Conservation System Kits With Curved Trocar Wound Drains (6/pkg) “The patients in the study group did not predonate blood, but had postoperative salvage and reinfusion from a sterile low continuous suction device during the first 6 hours after the operation.” 1. CBCII Blood Conservation Kit with 1/8” Round PVC Drain & Curved Trocar CBCII Blood Conservation Kit with 1/4” Round PVC Drain & Curved Trocar CBCII Blood Conservation Kit with 3/16” Round PVC Drain & Curved Trocar CBCII Blood Conservation System Kits With Double Trocar Wound Drains (6/pkg) 0225-028-614 0225-028-616 0225-028-626 CBCII Blood Conservation Kit with 1/8” Round PVC Drain & Double Trocar CBCII Blood Conservation Kit with 1/4” Round PVC Drain & Double Trocar CBCII Blood Conservation Kit with 3/16” Round PVC Drain & Double Trocar *Steven T. Woolson, MD and William W. Wall, MD/Stanford University Hospital, The Journal of Arthroplasty/Vol. 18/No. 3/2008. Cost Effective • Superior Safety • Easy to Use • Unique Fat Retention Valve • CBCII Blood Conservation System Kits With Quick Disconnect Kits (6/pkg) 0225-028-085 0225-028-914 0225-028-916 0225-028-926 CBCII CBCII CBCII CBCII with with with with Quick Quick Quick Quick Disconnect (drain not included) Disconnect, 1/8” Round PVC Drain & Trocar Disconnect, 1/4” Round PVC Drain & Trocar Disconnect, 3/16” Round PVC Drain & Trocar Optional Ambulating Bulb After blood has been collected, depress the transfer lever, hang the blood bag and infuse. The information presented in this brochure is intended to demonstrate the breadth of Stryker product offerings. Always refer to the package insert, product label and/or user instructions before using any Stryker product. Products may not be available in all markets. Product availability is subject to the regulatory or medical practices that govern individual markets. Please contact your Stryker representative if you have questions about the availability of Stryker products in your area. Products reference with ™ designation are trademarks of Stryker. Products referenced with ® designation are registered trademarks of Stryker. Blood Conservation through meaningful innovation. Steven T. Woolson,MD and William W. Wall,MD/Stanford University Hospital The Journal of Arthroplasty/Vol. 18/No. 3/2003 When use of the CBCII is complete, the ambulating bulb allows continued wound drainage for desired patient mobility. Literature Number: 9100-001-250 Rev. None UnDe/P.S. Copyright © 2009 Stryker Printed in USA 4100 East Milham Avenue Kalamazoo, MI 49001 USA t: 269 323 7700 f: 809 999 3811 toll free: 800 253 3210 www.stryker.com Blood Conservation through meaningful innovation.

Open the catalog to page 1
CBC II - 2

Blood Conservation System With over 15 years of successful reinfusions, the CBCII is an efficient and easy to use blood conservation system. It’s an effective and completely closed system with an internal vacuum and allows for postoperative reinfusion of the patient’s own blood. When blood reinfusion is complete, the CBCII has an optional ambulatory bulb for continued wound drainage while allowing patient mobility. It’s simple, reliable and is a completely closed system. • Battery operated Cost Effective “The use of post-operative blood salvage instead of pre-donated autologous blood to...

Open the catalog to page 2

All Stryker catalogs and technical brochures

  1. ACCOLADE® II

    20 Pages

  2. VariAx® 2

    20 Pages

  3. Prime TC®

    4 Pages

  4. OrthoMap®

    4 Pages

  5. Luxor

    4 Pages

  6. Aviator™

    2 Pages

  7. Aero® -C

    6 Pages

  8. Escalate®

    16 Pages

  9. Dynatran

    13 Pages

  10. Reflex®

    24 Pages

  11. OASYS®

    44 Pages

  12. SurgiCount

    4 Pages

  13. SmartPump

    2 Pages

  14. Revolution

    6 Pages

  15. Cast Vac

    2 Pages

  16. Cast Cutter

    2 Pages

  17. EasyClip

    2 Pages

  18. Neptune 2

    2 Pages

  19. Mixevac III

    2 Pages

  20. SDC 3

    2 Pages

  21. SmartTip ™

    3 Pages

  22. Gamma3 T

    6 Pages

  23. the Mill

    2 Pages

  24. GMRS

    13 Pages

  25. trident

    12 Pages

  26. System 7

    7 Pages