M.10 Accessories
13Pages

{{requestButtons}}

Catalog excerpts

M.10 Accessories - 1

Mechanical Pressure Switches sehctiwS erusserP lacinahceM

Open the catalog to page 1
M.10 Accessories - 2

Mating plugs, Socket devices and Thread adapters M.10 Zubehör für mechanische Druckschalter High-quality accessories Developed for our products Aligned to our products Originals from the manuf

Open the catalog to page 2
M.10 Accessories - 3

Mating plugs For pressure switches with integrated connector Deutsch DT06-2S (for DT04-2P) 2 x 0,5 mm² Radox cable, IP65 TE AMP Superseal 1.5®, 2-pin 2 x 0,5 mm² Radox cable, IP65 TE AMP Superseal 1.5®, 3-pin 3 x 0,5 mm² Radox cable, IP65 TE AMP Junior Timer, 2-pin 2 x 0,5 mm² Radox cable, IP65 Packard MetriPack 280, 2-pin 2 x 0,5 mm² Radox cable, IP65 Bayonet DIN 72585 A1-2.1 2 x 0,5 mm² Radox cable, IP65 All mating plugs with 2 m ca

Open the catalog to page 3
M.10 Accessories - 4

Socket devices and protective caps • IP65 socket devices or IP54 rubber protective caps for increased protection • Simple installation with plug-in socket devices 0 34 Rubber protective cap With central cable feed-through for 1.5 - 5 mm cable diameter Rubber protective cap With two cable feed-throughs for 1.7 - 2,2 mm cable diameter Rubber protective cap With two cable feed-throughs for 1.7 - 2,3 mm cable diameter Socket device cCSAus approval Housing: Polyamide PG9 screw fitting (tightening range 6 - 9 mm) With rubber protective cap fitted: IP54 Suitable for voltages up to 42 V With rubber...

Open the catalog to page 4
M.10 Accessories - 5

Socket device to DIN EN 175301-803-A (DIN 43650) PG9 screw fitting (tightening range 6 - 9 mm) terminals for wire crosssections: 0.34 ... 1.5 mm2 (AWG 22 ... AWG 16), tightening torque for terminal screw 0.4 Nm With socket device fitted: IP65 Suitable for voltages up to 250 V Socket device With indicator lamp to DIN EN 175301-803-A (DIN 43650) PG9 screw fitting (tightening range 6 - 9 mm) terminals for wire crosssections: 0.34 ... 1.5 mm2 (AWG 22 ... AWG 16), tightening torque for terminal screw 0.4 Nm With socket device fitted: IP65 Suitable for voltages up to 24 or 250 V Socket device...

Open the catalog to page 5
M.10 Accessories - 6

Thread adapters For requirements at short notice and for realising custom solutions • The materials and shapes of thread adapters are aligned perfectly to our switches and transmitters • Thread adapters are supplied with seals Vacuum switch All pressure switches and transmitters with SUCO thread code 15 with SUCO thread code 41 Dual nipple Thread adapters stainless steel (1.4305 / AISI 303) includes sealing ring NBR includes sealing ring stainless steel / NBR Order number: Order number: Order number: Order number: Order number: Order number:

Open the catalog to page 6
M.10 Accessories - 7

All hex 24 and hex 27 pressure switches with SUCO thread code 03 Pressure switch series 0183 with SUCO thread code 45 All hex 24 and hex 27 pressure switches with SUCO thread code 03 Thread adapters zinc-plated steel (CrVl-free) female thread female thread includes sealing ring FKM female thread includes copper sealing ring Flange design includes NBR O-ring Order number: Order number: Order number: Order number: Order number: Order number:

Open the catalog to page 7
M.10 Accessories - 8

Technical explanations for mechanical pressure switches Diaphragm pressure switch NO Piston pressure switch NC What is a mechanical pressure switch? Mechanical pressure switches from SUCO monitor the pressure of liquid or gaseous media, and close or open an electrical circuit on reaching a set threshold. Diaphragm pressure switches SUCO diaphragm pressure switches are used in pressure ranges from 0.1 bar to 100 bar, meaning overpressure safety of 35, 100, 300 and 600 bar, depending on the used diaphragm type. Piston pressure switches Pressure ranges from 10 bar to 400 bar can be monitored...

Open the catalog to page 8
M.10 Accessories - 9

Classification of electrical switch functions Contact form DIN EN60947-5-1 SPST single pole, single throw SPST single pole, single throw Changeover contacts CO, change over (snap action) SPDT single pole, double throw The switching point (for rising pressure) and hysteresis increase, whilst the switch-back point (for falling pressure) sinks. Also, the effect of the maximum (system) pressure on the switchback point (for falling pressure ramp) must be factored in for tolerance-critical applications. The higher the (system) pressure, the lower the resulting switch-back value. Potential-free –...

Open the catalog to page 9
M.10 Accessories - 10

Technical explanations for mechanical pressure switches Hysteresis can be set at SUCO in range from approx. 10 % (at end of adjustment range) to 30 % or higher (at start of adjustment range), related to the respective switching point for hex 27 and 30 A/F pressure switches with adjustable hysteresis. The specifications in the catalogue only represent typical average values. Please ask about the possible setting ranges you may require. Our electronic pressure switches are excellently suited to extremely low or high hysteresis. The lowest possible hysteresis is set if nothing is specified in...

Open the catalog to page 10
M.10 Accessories - 11

Conversion table for pressure units Water applications Standard piston switches are not suitable for water applications. Pressure switches in stainless steel with EPDM seal have a special sealing system and can therefore also be used for water with corrosion protection, water mixtures or emulsions. The use of other fluid mixtures should be clarified with SUCO (e.g. swelling of EPDM sealing could happen by water - oil mixture). Pressure switches with stainless ste^ housings with EPDM-TW diaphragm, SUCO type „5" are designed for the use of drinking water. Gas applications Our pressure...

Open the catalog to page 11
M.10 Accessories - 12

General technical explanations User information Our pressure monitoring products may only be installed and started up by authorised specialists. The safety regulations of country-specific authorities must be observed, especially when working with mains voltages and oxygen, and in potentially explosive areas. Product information The technical information in this catalogue is based upon fundamental testing during product development and empirical values. The information cannot be used for all application scenarios. Testing of the suitability of our products for a specific application (such as...

Open the catalog to page 12
M.10 Accessories - 13

RoHSII compliant Values 30% lower than in the table above must be used for brass housings. Gaseous applications In particular using additional sealant to attain the required leak tightness may be necessary for gas applications. Vacuum The values given in the technical details for the vacuum range are specified in millibars (mbar) below atmospheric pressure. Pressure change rate (~rise / ~fall) The pressure change rate denotes the pressure over time for the rising/falling pressure. The pressure change rate is specified in bar/s or bar/ms. The maximum pressure change rate for SUCO mechanical...