M.7 Hex 30, changeover
12Pages

{{requestButtons}}

Catalog excerpts

M.7 Hex 30, changeover - 1

Mechanical Pressure Switches sehctiwS erusserP lacinahceM

Open the catalog to page 1
M.7 Hex 30, changeover - 2

Changeover with silver contacts Attachment options for wall fitting and block style enable clearly structured, accessible, easy-maintenance installation Switching pressure can be adjusted easily by user High overpressure safety Socket devices enable simple installation on the ma

Open the catalog to page 2
M.7 Hex 30, changeover - 3

Technical details Temperature resistance of sealing materials: Electrical values

Open the catalog to page 3
M.7 Hex 30, changeover - 4

M.730 A/F 0159 Diaphragm / piston pressure switch up to 250 V • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 200 / 600 bar1) • Switching point continuously adjustable by turning knurled screw whilst system in operation Order number With female G 1/4 thread 0159 Diaphragm pressure switches 0159 Piston pressure switches Seal material - Application areas Refer to page 75 for the temperature range and application thresholds of sealing materials. Your order number: 0159 - XXX 14 - X - 001 1) Static value. Dynamic value is 30-50 % lower. Values pertain to the...

Open the catalog to page 4
M.7 Hex 30, changeover - 5

0161 / 0162 Diaphragm / piston pressure switch up to 250 V • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 200 / 600 bar1) • Socket device similar to DIN EN 175301 (DIN 43650) • Hysteresis adjustable at factory Order number 0161 with female thread With female G 1/4 thread 0161 Diaphragm pressure switches 0161 Piston pressure switches Refer to page 75 for the temperature range and application thresholds of sealing materials. Your order number: 016X - XXX 14 - X - 001 1 Adjusting the set point To adjust the set point, undo the locknut and adjust the set...

Open the catalog to page 5
M.7 Hex 30, changeover - 6

0175 Diaphragm pressure switches up to 250 V • For low pressure, high accuracy • Aluminium housing • Changeover with silver contacts • Overpressure safety up to 25 bar1) • Socket device similar to DIN EN 175301 (DIN 43650) • Hysteresis adjustable at factory Order number Hydraulic/machine oil, heating oil, air, nitrogen, etc. Your order number: Adjusting the set point To adjust the set point, undo the locknut and adjust the set screw M16 using a screwdriver. Clockwise screwing increases the switching pressure. After adjusting, tighten the locknut again. RoHSII compliant 1 Static value....

Open the catalog to page 6
M.7 Hex 30, changeover - 7

Technical explanations for mechanical pressure switches Diaphragm pressure switch NO Piston pressure switch NC What is a mechanical pressure switch? Mechanical pressure switches from SUCO monitor the pressure of liquid or gaseous media, and close or open an electrical circuit on reaching a set threshold. Diaphragm pressure switches SUCO diaphragm pressure switches are used in pressure ranges from 0.1 bar to 100 bar, meaning overpressure safety of 35, 100, 300 and 600 bar, depending on the used diaphragm type. Piston pressure switches Pressure ranges from 10 bar to 400 bar can be monitored...

Open the catalog to page 7
M.7 Hex 30, changeover - 8

Classification of electrical switch functions Contact form DIN EN60947-5-1 SPST single pole, single throw SPST single pole, single throw Changeover contacts CO, change over (snap action) SPDT single pole, double throw The switching point (for rising pressure) and hysteresis increase, whilst the switch-back point (for falling pressure) sinks. Also, the effect of the maximum (system) pressure on the switchback point (for falling pressure ramp) must be factored in for tolerance-critical applications. The higher the (system) pressure, the lower the resulting switch-back value. Potential-free –...

Open the catalog to page 8
M.7 Hex 30, changeover - 9

Technical explanations for mechanical pressure switches Hysteresis can be set at SUCO in range from approx. 10 % (at end of adjustment range) to 30 % or higher (at start of adjustment range), related to the respective switching point for hex 27 and 30 A/F pressure switches with adjustable hysteresis. The specifications in the catalogue only represent typical average values. Please ask about the possible setting ranges you may require. Our electronic pressure switches are excellently suited to extremely low or high hysteresis. The lowest possible hysteresis is set if nothing is specified in...

Open the catalog to page 9
M.7 Hex 30, changeover - 10

Conversion table for pressure units Water applications Standard piston switches are not suitable for water applications. Pressure switches in stainless steel with EPDM seal have a special sealing system and can therefore also be used for water with corrosion protection, water mixtures or emulsions. The use of other fluid mixtures should be clarified with SUCO (e.g. swelling of EPDM sealing could happen by water - oil mixture). Pressure switches with stainless ste^ housings with EPDM-TW diaphragm, SUCO type „5" are designed for the use of drinking water. Gas applications Our pressure...

Open the catalog to page 10
M.7 Hex 30, changeover - 11

General technical explanations User information Our pressure monitoring products may only be installed and started up by authorised specialists. The safety regulations of country-specific authorities must be observed, especially when working with mains voltages and oxygen, and in potentially explosive areas. Product information The technical information in this catalogue is based upon fundamental testing during product development and empirical values. The information cannot be used for all application scenarios. Testing of the suitability of our products for a specific application (such as...

Open the catalog to page 11
M.7 Hex 30, changeover - 12

RoHSII compliant Values 30% lower than in the table above must be used for brass housings. Gaseous applications In particular using additional sealant to attain the required leak tightness may be necessary for gas applications. Vacuum The values given in the technical details for the vacuum range are specified in millibars (mbar) below atmospheric pressure. Pressure change rate (~rise / ~fall) The pressure change rate denotes the pressure over time for the rising/falling pressure. The pressure change rate is specified in bar/s or bar/ms. The maximum pressure change rate for SUCO mechanical...