• Products
  • Catalogues
  • News & Trends
  • Exhibitions

Advance 8L Instructions - 1 Pages

  1. P. 1

Catalogue excerpts

2 x 4 Canister Cascade System or 8 x Canister Cascade System INSTRUCTIONS FOR USE for ADVANCE 2 x 4 Canister Cascade System or 8 x Canister Cascade System Connection and use: Read all instructions thoroughly before attempting to use this equipment. Pay special attention to warnings and precautions - these are indicated thus Before use, check the product has not reached its use by date. This can be found printed on the liner and packaging label. The 2 x V Stand is designed to be used with either 2 sets of 4 canisters or 1 set of 8 canisters. The two taps located on the yellow tubing from the vacuum controller enables the unit to be switched from using the top set of liners to the bottom set of liners or if taps are left switched on then the unit can operate using 8 liners. To set up to use 2 x 4 liners. Place 3 Blue Cap Liners and 1 Green Cap Liner in each set of 4. Ensuring at all times that the tapered connector attached to the yellow vacuum tubing only goes into a GREEN Cap Liner. 1 Place ONE GREEN CAP LINER into the canister to the left of the 3 front of Suction Controller. Attach yellow tubing with tapered connector from the suction controller to the vacuum port of the GREEN CAP LINER. 2 Place BLUE CAP LINERS in remaining canisters. 3 Using VacSax cascade tubing, connect the patient port of the GREEN CAP LINER to the vacuum port of the second blue liner; continue until the last liner is reached, ensuring all tubing connectors are pushed firmly onto patient and vacuum ports. Turn on suction controller and set to maximum vacuum level. 4 Connect your patient tubing to the patient port of the last BLUE CAP LINER. Confirm vacuum is present by manually occluding the patient port of the last blue liner. Ensure all liners are fully inflated. Repeat the above on the lower layer of the stand. To use as a 8 liner system set up as above but using 7 Blue Cap Liners and 1 Green Cap Liner and ensure taps are open. AFTER USE ENSURE you wear gloves TAP OPEN IMPORTANT! DO NOT TURN OFF VACUUM SOURCE WHILE DISCONNECTING THE LINER SYSTEM, if system has been overfilled fluids may pass back down the patient tubing. Starting at the liner with the patient tubing connected - Disconnect patient tubing from the patient port. Remove the small patient port stopper from the outer rim of the liner cap by twisting to snap-off. Press the stopper firmly into patient port. VacSax Limited, Western Wood Way, Langage Science Park, Plymouth, PL7 5BG, UK. T:+44 (0)1752 337000 F:+44 (0)1752 337600 Disconnect the cascade tubing from the liner vacuum port and press the large yellow stopper firmly into the port. Continue until all liners are disconnected and sealed. Conforms to: 93/42EEC Medical devices directive Important information Latex Free Packaging 100% Recycled 100% Recyclable

 Open the catalogue to page 1

All VacSax catalogues and technical brochures

  1. Accessories

    4 Pages

    En
  2. BactiClear®

    2 Pages

    En
  3. VacSax Advance

    4 Pages

    En
  4. S-Scort® Duet

    2 Pages

    En
  5. Vommax®

    2 Pages

    En
  6. FumeVax

    1 Pages

    En