CERAMOTHERM
16Pages

{{requestButtons}}

Catalog excerpts

CERAMOTHERM - 1

Warming is protection Baby changing and care Examination and treatment

Open the catalog to page 1
CERAMOTHERM - 2

In certain situations many patients need support in order to maintain their body temperature. This applies equally to babies during nappy changing, infants under longer examination as well as to adult theatre preparation and recovery patients. Above all newborn and preterm babies require a maximum amount of warming and protection. Their metabolism is immature and they are extremely sensitive to temperature changes and other ambient influences. All these patients require an efficient and safe heating source. Intensity selection Efficient warming Radiant warmers CERAMOTHERM keep the patient...

Open the catalog to page 2
CERAMOTHERM - 3

Even distribution of heat Long-life ceramic heating elements create a steady and cosy warming at a low power consumption. They do not scale and are resistant to liquid splashes. Integrated illumination, dazzlefree Two fluorescent lamps with natural light colour Illuminate the patient area dazzle- CERAMOTHERM 1000 is suitable for less sophisticated and short-term application, e.g. nappy changing and examination. CERAMOTHERM 2000 provides additional safety features and is therefore also suitable for long-term and Intensive care. Individual selection of intensity The requirement of heat varies...

Open the catalog to page 3
CERAMOTHERM - 4

The radiant warmers are available in two sizes CERAMOTHERM 1100 / 2100 CERAMOTHERM 1200 / 2200 with 1 heating element 600 Watt with 2 heating elements 400 Watt each 220 220 0 71 0 45 100 100 900 900 0 520 0 62 77 520 For babies For babies, children and adults CERAMOTHERM 1100 Postnatal care Baby changing Examination CERAMOTHERM 1200 Examination Physical therapy Prewarming of patient beds CERAMOTHERM 2100 Postnatal care Baby changing Examination Intensive care Care of preterm babies CERAMOTHERM 2200 Examination Operation theatre preparation and recovery Intensive care Care of burn center...

Open the catalog to page 4
CERAMOTHERM - 5

Postnatal care and baby changing Static arrangement to the patient area Wall holder Ceiling bracket, distance between patient pad and bottom line of solid ceiling max. 2600 mm. Wall holder, lateral mounting CERAMOTHERM 1100 CERAMOTHERM 1100 CERAMOTHERM 1100 Order No. WY1117 Order No. WY1115 Order No. WY1116 CERAMOTHERM 1200 CERAMOTHERM 1200 Order No. WY1217 Order No. WY1216 CERAMOTHERM 2100 CERAMOTHERM 2100 CERAMOTHERM 2100 Order No. WY2117 Order No. WY2115 Order No. WY2116 CERAMOTHERM 2200 CERAMOTHERM 2200 Order No. WY2217 Order No. WY2216 5

Open the catalog to page 5
CERAMOTHERM - 6

Flexible arrangement to the patient area Wall arm 320 mm length, horizontal swiveling 180° with fixing facility, rotation of warmer 360° CERAMOTHERM 1100 Order No. WY1101 CERAMOTHERM 2100 Order No. WY2101 Upgrade option: Vertical adjustment ± 45° Upgrade option: Vertical extension 250 mm Order No. WY1822 Order No. WY1846 Arrangement examples 225 mm 280 mm 760 mm WY1101/WY2101 WY1101/WY2101 W Y1 10 2/ W Y2 10 2 600 mm 245 Wall 6 WY1101/WY2101

Open the catalog to page 6
CERAMOTHERM - 7

VARIOTHERM Easz Care Mobile baby changing and examination unit with integrated radiant warmer The mobile baby changing unit VARIOTHERM Easy Care is a very useful alternative to a fixed location baby changing facility with a ceiling or wall mounted radiant warmer. The VARIOTHERM Easy Care can be used for nappy changing, examination and treatment independently in any room. If necessary, patient rooms can be arranged as mother and child rooms very quickly and the babies can be transferred with the device to the babycare unit or examination area. In order to have all necessary items for...

Open the catalog to page 7
CERAMOTHERM - 8

Further arrangements Horizontal swiveling 180° with fixing facility, rotation of warmer 360° Wall arm 480 mm length CERAMOTHERM 1100 CERAMOTHERM 1200 Order No. WY1102 Order No. WY1202 CERAMOTHERM 2100 CERAMOTHERM 2200 Order No. WY2102 Order No. WY2202 Wall arm 600 mm length CERAMOTHERM 1100 CERAMOTHERM 1200 Order No. WY1103 Order No. WY1203 CERAMOTHERM 2100 CERAMOTHERM 2200 Upgrade options: Vertical adjustment ± 45° Order No. WY1822 Vertical extension 250 mm Order No. WY1846 Order No. WY2103 Order No. WY2203 Double-joint wall arm R1 = 480 mm, R2 = 480 mm, horizontal swiveling 180° with...

Open the catalog to page 8
CERAMOTHERM - 9

Height-adjustable mounting systems For certain applications radiant warmers must be arranged in a flexible manner to allow sufficient freedom of motion to the patient or in order to warm specific body parts. Also for mobile care beds or height adjust- able examination couches a radiant warmer with variable height and swivel facility is required. The same applies for the operation theatre in order to prevent patients from becoming hypothermic during preparation For these applications a double-joint swivel arm with large radius and flexible swivel head allows to arrange the radiant warmer in...

Open the catalog to page 9
CERAMOTHERM - 10

Wall mount R1 180° 360° 2 R 360° ± 45° Automatic distance detection Double-joint wall arm, extension arm R1 = 750 mm, swiveling 180°, height-adjustable spring balanced arm R2 = 800 mm, adjustable stop for highest position, rotation of warmer 360°, vertical adjustment ± 45°. CERAMOTHERM 2100 CERAMOTHERM 2200 With distance detection Order No. WY2107 Order No. WY2207 CERAMOTHERM 1100 CERAMOTHERM 1200 Without distance detection1) Order No. WY11071) Order No. WY12071) Option: 1) Application to babies and defenseless persons under surveillance only 10 Extension arm R1 = 950 mm Order No. WY1847

Open the catalog to page 10
CERAMOTHERM - 11

Ceiling mount R1 360° 360° 2 R 360° ± 45° Automatic distance detection Ceiling bracket with double-joint arm, extension arm R1 = 750 mm, swiveling 360°, height-adjustable spring balanced arm R2 = 800 mm, adjustable stop for highest position, rotation of warmer 360°, vertical adjustment ± 45°. Distance between patient pad and bottom line of solid ceiling 1800 to 2600 mm. CERAMOTHERM 2100 CERAMOTHERM 2200 With distance detection Order No. WY2108 Order No. WY2208 CERAMOTHERM 1100 CERAMOTHERM 1200 Without distance detection1) Order No. WY11081) Order No. WY12081) Distance between patient pad...

Open the catalog to page 11
CERAMOTHERM - 12

Mobile use The flexible swivel head allows to precisely direct the radiation to the patient. Patient leve l As an option to radiant warmers mounted at the wall or the ceiling, a mobile unit is recommended when the warmer will be used in different rooms or if due to constructional reasons a fixed mounting is not possible. The height-adjustable stand is mobile on four antistatic castors, two of them can be kickstopped. The distance mark and the patient pad must be on the same level, thus securing the safety distance between radiant warmer and patient. Mobile stand, adjustable to patient level...

Open the catalog to page 12