video corpo

MOST Option System for Severe Bone Loss
6Pages

{{requestButtons}}

Catalog excerpts

MOST Option System for Severe Bone Loss - 1

Zimmer ® MOST Options® System Modular Knee and Hip Options for Severe Bone Loss Trauma and Revision Confidence in your hands'

Open the catalog to page 1
MOST Option System for Severe Bone Loss - 2

MOST Options® System Modular Knee and Hip Options for Severe Bone Loss, Trauma and Revision MOST Options Severe Revision Knee and Hip System provides maximum intraoperative options to match each patient’s needs. Severe bone loss cases require freedom of choice. That’s why the anatomic, modular MOST Options System gives you maximum intraoperative flexibility in implant selection, connection and fixation. The system offers a wide variety of implant sizes, segments, adapters and stems to accommodate these complex cases. The MOST Options System helps patients with problems that require surgery...

Open the catalog to page 2
MOST Option System for Severe Bone Loss - 3

Rotating Hinge with All Poly Sleeve Instruments The MOST Options trials and instruments were developed specifically for this system to provide accurate and reproducible results. Trials precisely match implant geometry, allowing true intraoperative verification of the final implant fit. Innovative instruments complete the surgical system. Resection Guide • Accurately determines severe bone resection level • Reference for joint line Femoral Sizing Guide • Sizes the distal femur in relation • Determines anterior flange height position per implant size Tibial Broach and Tibial Baseplate Trial •...

Open the catalog to page 3
MOST Option System for Severe Bone Loss - 4

Proximal Femoral Replacement Hinged Femoral Design with Proximal Tibia Replacement Distal Femur Replacement Situation: • 21-year-old male with three months of distal thigh and knee pain • Biopsy proved osteosarcoma • Patient underwent postoperative chemotherapy Solution: • MOST Options distal femur replacement with rotating hinge knee • 120 degrees of flexion and full extension with no significant extensor lag • Ambulatory without limp Total Femur Replacement Situation: • 46-year-old male with multiple failed implants subsequent to trauma • Loosened long stem THR • Severe distal bone...

Open the catalog to page 4
MOST Option System for Severe Bone Loss - 5

Treatment Options The MOST Options System has four levels of options to provide maximum intraoperative flexibility based on surgical indication, implant selection, connection choice and fixation. The system allows a physician the flexibility to use bone replacing implants or resurfacing implants for bulk allograft solutions. Some of these alternatives are shown in the proximal/distal femoral and proximal tibial options. The MOST Options rotating hinge is the key to intraoperative flexibility. The innovative rotating hinge design allows any of the femoral and tibial options shown to easily...

Open the catalog to page 5
MOST Option System for Severe Bone Loss - 6

Contact your Zimmer representative or visit us at www.zimmer.com

Open the catalog to page 6

All Zimmer Biomet catalogs and technical brochures

  1. A.L.P.S.®

    44 Pages

  2. Biologics

    24 Pages

  3. Sidus

    40 Pages

  4. ZImmer iASSIST

    44 Pages

  5. Persona Knee

    6 Pages

Archived catalogs