カタログの抜粋

OPTIONAL VENA CAVA FILTERS & The ALN Removal and/or Repositioning Kits
カタログの1ページ目を開く
The ALN Optional Vena Cava Filters
カタログの2ページ目を開く
THE ALN OPTIONAL VENA CAVA FILTERS Permanent and/or temporary intended to be retrievable at any time* Easy to implant Excellent corrosion resistance Unique design Upper level for anchoring Lower level for centering Different length of the legs to minimize the risk of legs interlacing Legs are at two different levels: Upper level for anchoring (6 shorter legs) Lower level for centering (3 longer legs) Introducer sheath= low profile 7F Retrieval sheath= low profile 9F Legs’ configuration minimizes the risk of cava penetration * please refer to our local distributor for retrieval approved
カタログの4ページ目を開く
The only retrievable IVC filters > manufactured in stainless steel > approved with an indicated IVC diameter up to 32 mm (CE Mark) The choice is yours! The ALN Vena Cava Filter with hook can be removed using one of the ALN Removal Kits or using a lasso (Only by jugular approach) ALN Filter with Hook more options to retrieve the filter
カタログの5ページ目を開く
THE ALN OPTIONAL VENA CAVA FILTERS
カタログの6ページ目を開く
THE ALN VENA CAVA FILTERS Removal and/or Repositioning Kits Unique 2 in 1 RS ALN vena cava removal and/or repositioning kits Only by jugular approach Pincer specially designed to catch the apex of the filter Ability to change the angle of the pincer
カタログの7ページ目を開く
The ALN OATF Optional Vena Cava Filter Just like the original, talented and reliable The ALN OATF Optional Vena Cava Filter with and without hook Based on the expertise and experience of ALN The only optional IVC Filter in Stainless steel without welding points: 3T MRI Compatible 4 approaches The only Optional IVC Filter approved to be implanted in patient whose vena cava diameter is less than or equal to 32 mm ^Enhanced stability with its 3 anti-tilting legs
カタログの8ページ目を開く
A design with an unique technology: legs anchoring legs Optimal Design Anti-tilting legs for an optimum centering centering legs Anchoring legs with an anti-transfixion loop to minimize the risk of cava penetration Centering legs The ALN OATF optional IVC Filter with hook can be removed with one of our three extraction kits and/or a lasso THE ALN OATF OPTIONAL VENA CAVA FILTER
カタログの9ページ目を開く
The mean interval between implantation and retrieval was 25.6 months (range, 14.8- - 40.8 months), and extractions were performed on eight patients who had received a filter at least 2 years earlier. The longest dwell time was 40 months. All filters were extracted successfully without complications. Conclusions: Optional ALN filter retrievals can be performed safety after more than 1 year following implantation. “Successful retrieval of 29 ALN Inferior Vena Cava Filters of 25.6 Months after placement.” Olivier Pellerin, MD - Massimiliano di Primio, MD -Olivier Sanchez, MD, PhD - Guy Meyer,...
カタログの10ページ目を開く
ALN S.A.R.L. LEGAL MANUFACTURER Route de la gare 20240 GHISONACCIA FRANCE MANUFACTURING SITE 589, Chemin du Niel 83230 BORMES LES MIMOSAS FRANCE Tel. +33 (0)4 94 01 05 01 Q Fax. +33 (0)4 94 01 09 01 contact@aln2b.com W www.aln2b.com #
カタログの12ページ目を開くALN Implants Chirurgicauxのすべてのカタログと技術パンフレット
-
The ALN Removal Kits
4 ページ
-
ALN Vena Cava Filter
4 ページ