General Specifications The NuLook Manifold System shall be manufactured by Amico Corporation in accordance with job specific shop drawings and documents. The following is a general specification, and components listed may not be present or required in final product. The NuLook Manifold System is listed by the Underwriters Laboratories Inc. (UL) in Canada and the United States of America. Amico Corporation manufactures all products in accordance with the CSA Z7396.1 standard, National Fire Protection Association (NFPA), NFPA-99 (current edition), National Electric Code (NEC), and the Canadian Electrical Code (CEC). The NuLook Manifold is Made Up of Several Integral Components: • ertical sections where the services are located. These V components have optional vertical and/or horizontal rails systems and reveals as well as 3D wrap finished front panels attached. These sections are installed on the finished wall. • entral section with removable 3D wrap panels for bed C area. This component is located between the vertical sections, installed on the finished wall and has optional horizontal/vertical aluminum reveals or rails. It can accommodate bed bumpers and decorative resin panels with built-in LED lights. Please refer to approved submittal drawings for project specific details. • ecorative side vertical sections with removable 3D wrap D panels. These components are located to the left or right of the vertical sections, are installed on the finish wall and have optional horizontal/vertical aluminum reveals or rails. Please refer to approved submittal drawings for project specific details. Submittals and Verifications Job specific shop drawings shall be produced for each project. Final shop drawings will include the size and location of the gas manifolds. As Built drawings will be produced and e-mailed at the time of shipment. Amico Corporation will manufacture equipment as per signed approval drawings and verification documents which are provided in the job specific submittal package.
カタログの1ページ目を開く
Low Voltage Data Provisions Numbers of integrated rails (horizontal and vertical) are to match final shop drawings. Accessory rails are clear etched anodized aluminum. This shall be connected to a device junction box via conduit or raceway. Amico Corporation shall include a pull cord extending from junction box to service provision. Telephone nurse call patient station device shall be furnished, installed and wired by low voltage contractor. Electrical Receptacles Integrated Accessory Rails (Optional) Amico Corporation's DISS or quick connection type, console style. Each gas outlet comes...
カタログの2ページ目を開くAmicoのすべてのカタログと技術パンフレット
-
NuLook FlexWall
2 ページ
-
NuLook Casework
2 ページ
-
Recessed Console
2 ページ
-
Patient Room Furniture
12 ページ
-
Air and Vacuum Systems
20 ページ
-
Suction & Oxygen Therapy
16 ページ
-
nulook_casework
20 ページ
-
Architectural brochure
24 ページ
-
Accessories
20 ページ
-
Majestic Series
3 ページ
-
arch brochure
28 ページ
-
Clinical Solutions 2015
20 ページ
-
Regal Series
3 ページ
-
Reflection Series
2 ページ
-
Freedom Series
2 ページ
-
Architectural Headwalls
28 ページ
-
Medical Gas Pipeline
16 ページ
-
Clinical Solutions
20 ページ
-
Casegoods
16 ページ
-
Laboratory Products
20 ページ