カタログの抜粋

Innovation with Integrity Defence CBRNE
カタログの1ページ目を開く
New Dimension in NC Detection The development of the very latest Bruker detection system stems from recognition that the security situation in recent years has changed considerably. Customers now acknowledge the existence of asymmetric threats and a new capability is required to reflect these changes. It has been widely reported that there are many radiation sources worldwide that terrorists could use in combination with conventional explosives to produce a „dirty bomb“. Recent intelligence suggests that conventional explosives could also be used in conjunction with Chemicial Warfare Agents...
カタログの2ページ目を開く
Clear and Unambiguous Indification of Nuclear and Chemical Threats The two display concept provides a clear and unambiguous indication of the NC threat assessment. A warning is given by acoustical and optical alarm. The RAID-XP has an internal memory for the results of the N and C sensors in combination with time and geographic location, which can be provided by a GPS receiver. The RAID-XP is able to identify, classify, quantify, and continuously monitor concentration levels of CWA’s specified. The identity of substances detected is either indicated by class “G”, “H” or “T”, or the specific...
カタログの3ページ目を開く
Technical Specifications Detection range Low ppb up to several ppm (substance specific) Basic Unit Weight 6,7 kg (without battery) Spare parts No requirement to change consumables when RAID-XP detects a challenge, any consumables used are kept to a minimum and have maximum life. Low-maintenance concept for the operator Power Supply External power supply, accumulator/ battery Low voltage DC power (10-30 V DC nominal) Mains power supply: 230 V 50 Hz (110 V 60 Hz) AC 0,5 - max. 4A Radiation active source Ni-63 with 100 MBq activity Battery Lithium MnO2 battery, non rechargeable (Weight: 3,3...
カタログの4ページ目を開くBruker Daltonics Inc./ブルカーのすべてのカタログと技術パンフレット
-
IntelliSlidesTM
2 ページ
-
CMC-assist
2 ページ
-
Toxtyper
8 ページ
-
Product Overview
16 ページ
-
spotOn™
4 ページ
-
Metabolomics
8 ページ
-
TASQ Software
4 ページ
-
timsTOF™
8 ページ
-
TargetScreener
6 ページ
-
timsTOF Pro
6 ページ
-
Quant Proteomics
8 ページ
-
MBT Galaxy RUO
4 ページ
-
MBT Pilot RUO
4 ページ
-
MBT SMART IVD
4 ページ
-
MBT Consumables RUO
4 ページ
-
MBT Sepsityper
6 ページ
-
MBT BTS US
2 ページ
-
MBT Pharma
8 ページ
-
MALDI Imaging
16 ページ
-
MALDI Biotyper CA System
12 ページ
-
Bruker ToxScreener
6 ページ
-
ProteinScape
8 ページ
-
maxis II
12 ページ
-
EVOQ
6 ページ
-
impact II
12 ページ
-
micrOTOF II
8 ページ
-
ImagePrep
4 ページ
-
DE-tector
6 ページ
-
pTD
2 ページ
-
RAID AFM
4 ページ
-
RAID S2
6 ページ
-
RAID M100
6 ページ
-
MM2
6 ページ
-
SVG 2 and Probes
6 ページ
-
µRAID
4 ページ
-
VeroTect
4 ページ
-
SIGIS II
2 ページ
-
solarix XR
12 ページ
-
The new autoflex speed
10 ページ
-
Product Overview
20 ページ
-
impact HD
12 ページ
-
Toxtyper
6 ページ
-
micrOTOF-Q III
6 ページ
カタログアーカイブ
-
EVOQ - 2014
6 ページ