Product Data 39SH,SV,SM,SR00-17 Indoor and Outdoor Air Handlers The 39S series air handlers offer: • Horizontal and vertical draw-thru arrangements for heating, cooling, ventilation, and VAV (variable air volume) applications • Small footprint, which assures rigging ease and reduced space requirements Features/Benefits Delivering the air handler components for many stringent specification requirements, the 39S series air handlers are compact and fully assembled; they combine versatility with economical, dependable performance. Dependable performance Copyright 2008 Carrier Corporation Galvanized steel panels ensure structural integrity under all operating conditions. Double-walled hinged access doors on outdoor units also enhance structural stability and provide fast, easy access. Optional stainless steel drain pan controls condensate. Internally mounted motors and drives are installed and aligned at the factory. Because they are contained in a cooled, filtered, dehumidified airstream, motor bearings and belts have less wear and require less servicing. Internal mounting also reduces installation time, shipping damage, and vandalism.
カタログの1ページ目を開く
Features/Benefits (cont) Precision-balanced fan wheels limit vibration and eliminate abnormal stress on bearings and other components. Fan bearings are rated at 200,000 hours average life. Mixing boxes and filter mixing boxes have parallel blades to provide thorough, efficient air mixing. Dampers are sectioned to prevent excess blade warping and ensure tight closure. Coil flexibility Factory assembled, prealigned drives and fans eliminate field installation expense, saving money. Small envelope size is easy to rig and ensures economical use of building space. Quicker, easier installation...
カタログの2ページ目を開く
Model number nomenclature Due to the complexity of the 39S model number, use the "verify model number" function in the AHL/Builder® software for a detailed model explanation. Product Type/Unit Arrangement H - Belt Drive Horizontal Unit Unit Size - Nominal Tons Cooling Coil Heating Coil Coil Configuration TXV — Thermostatic Expansion Valve *Contact your local Carrier representative for a list of available unit arrangements. fContact your local Carrier representative for a list of factory- installed options. **Unit shall be factory wired. Field must switch transformer tap Design Revision...
カタログの3ページ目を開く
Factory-installed options ITEM MERV 7, 2 in. Pleated Filter Throwaway Filters for Face, Bypass, and Filter Sections Indoor Air Quality (IAQ) Insulation Closed Cell Insulation Double Wall Insulation Motor Start/Stop Station* Plastic Drain Pan† Stainless Steel Drain Pan** Galvanized Steel Drain Pan Std — X — — — Std/— — Std/X — Std X X X Std/X Std/X Std/X LEGEND Standard Item Optional Item Unavailable Item Standard or Unavailable Item Depending on Unit Size Standard or Optional Item Depending on Unit Size *Motor start/stop station is not available with electric heat on 39SH units or with 2...
カタログの4ページ目を開く
Application data Vertical (indoor unit only) Central station air handler The central station air handler is a heating, ventilating, or air-conditioning unit that is centrally located in, or on, a building or structure and from which air is distributed to desired areas through a system of ducts. The 39S factory packaged unit Individual components, such as fans, coils, and filters, are assembled at the factory. Packaged equipment is less costly than field-fabricated equipment and does not require assembly. The basic air-handling unit consists of a fan section, coil section, and filter. Other...
カタログの5ページ目を開く
Application data (cont) Fan selection criteria System requirements — The major factors that influence fan selection are airflow, external static pressure, fan speed, brake horsepower, and sound level. Additional system considerations include the fan control method, overloading, and non-standard air density. Fan selection for air-conditioning service usually involves choosing the smallest fan that provides an acceptable level of performance, efficiency, and quality. Pressure considerations — The static pressure is the resistance of the combined system apart from the fan. Contributors to...
カタログの6ページ目を開く
Sound considerations — The fan is one of the main sound sources in an air-conditioning system. Other sources of sound include the duct system and terminals, because they generate turbulence in the air flowing through them. Simply estimating fan sound does not give an accurate picture of total system sound, but because fan sound is a major component of system sound, fan sound should be minimized. To minimize its sound generation, a fan must be correctly sized and should be selected to operate at or near peak efficiency. Oversized fans can generate much higher sound power levels than...
カタログの7ページ目を開く
Application data (cont) Power losses in the motor and drive should be allowed for when determining the motor output (bhp), so that the motor can be correctly sized and so that the additional heat output can be subtracted from cooling capacity or added to heating capacity. A typical example follows: Given Fan Operating Point: 13,224 cfm 9.6 Fan bhp 3.0% estimated drive loss Calculate the required fan motor output (Hp) due to drive loss: Hp = (Fan bhp) x (Drive Loss) Hp = 9.6 x 1.03 Hp = 9.89 hp (select 10 Hp motor) Calculate the total fan motor heat output (Q) according to motor efficiency:...
カタログの8ページ目を開く
System parameters Before a fan type or control is selected, the system must be analyzed at both the design point and part load. The fan is likely to be operating at part load a large percentage of the time. Methods of fan air-volume control • “Riding the fan curve” with terminal throttling (forward curved fans) • Variable frequency drives (VFDs) A short description of these control methods follows. A summary comparison table is provided at the end of the section. Forward-curved (FC) fans with terminal throttling (riding fan curve) — This is the simplest, most reliable, and most economical...
カタログの9ページ目を開くCarrier| Commercial Systems North Americaのすべてのカタログと技術パンフレット
-
WeatherMaker® 50TCQ
116 ページ
-
INFINITY™ 38MPRA
2 ページ
-
ActivAIR™ 36CB
24 ページ
-
ACTIVAIR™ 36IB
44 ページ
-
Axis™
2 ページ
-
AHUBuilder
2 ページ
-
PERFORMANCE™ 50VL-A
6 ページ
-
50ZPB
4 ページ
-
PERFORMANCE™ 50VT-A
6 ページ
-
39CC
2 ページ
-
A World of Comfort
2 ページ
-
48P WEATHERMASTER®
168 ページ
-
48A WEATHERMAKER®
116 ページ
-
48PG CENTURION?
107 ページ
-
48PM CENTURION?
64 ページ
-
48TC WEATHERMAKER®
116 ページ
-
48HC WEATHERMASTER®
124 ページ
-
48LC WEATHEREXPERT®
52 ページ
-
48VL Performance? 14
32 ページ
-
48XL-A
30 ページ
-
48XL Infinity? 15
26 ページ
-
OMNIZONE?
80 ページ
-
16TJ
32 ページ
-
AQUAFORCE® 30XW150-400
60 ページ
-
EVERGREEN® 23XRV
32 ページ
-
AQUAFORCE® 30XA
150 ページ
-
30RB AQUASNAP®
92 ページ
-
30RAP AQUASNAP®
88 ページ
-
39L AERO®
52 ページ
-
39M AERO®
110 ページ
-
19XR EVERGREEN®
56 ページ