カタログの抜粋

Product Data 36IBAC,N,R,S,M,L,J Series Induction Beams 60 to 1,285 cfm
カタログの1ページ目を開く
Features/Benefits Induction beam systems provide individual temperature control and increased system energy efficiency, which may contribute to meeting the requirements of the LEED green building certification program.1 Carrier induction beam units offer: • Higher capacities than chilled beams • Sensible and latent cooling and heating options • Full drain pans meeting IBC (International Building Code) requirements • Independent testing by ETL Intertek • AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certified coil performance Induction beam systems An induction beam takes a...
カタログの2ページ目を開く
Design Revision A - Current Design Product Style C - All Way Discharge Cassette J - 1-Way Linear L - 2-Way Linear M - 1-Way Reversible PA Inlet Square N - 1-Way Discharge Narrow S - 1-Way Discharge Square r - 1-Way Reversible PA Inlet Linear Unit Finish A - White Painted Cabinet B - Off White Painted Cabinet C - Black Painted Cabinet X - Special Y - Galvanized Steel Insulation A - Exterior Closed Cell B - Collar Closed Cell Y - None Unit Size - Footprint (in.) A - 48 x 12 (36IBAN) B - 48 x 24 (36IBAL, J, N, R) C - 24 x 24 (36IBAC, L, J, S, M) D - 48 x 48 (36IBAC) E - 72 x 24 (36IBAL, J) F -...
カタログの3ページ目を開く
Physical data 36IBAC UNIT PHYSICAL DATA 36IBAR UNIT PHYSICAL DATA LEGEND ETO — Engineered to Order * Available in 2-way blow design only.
カタログの4ページ目を開く
Options and accessories Factory-installed options Induction nozzles are available in various sizes to match capacity requirements. Coils are available in 2-pipe and 4-pipe configurations. Grilles are available in various colors, and can be lay-in or surface mounted type with egg-crate, perforated, or louver face. The standard grille finish consists of a baked-on acrylic enamel that is corrosion resistant to 100 hours in a salt spray test. The optional alkyd enamel finish is a glossy, mar-resistant baked-on finish with a salt spray resistance to 175 hours. The optional urethane coating...
カタログの5ページ目を開く
Dimensions 36IBAC 2 x 2, ALL-WAY BLOW, 2-PIPE UNIT DIMENSIONS FRONT VIEW RIGHT SIDE VIEW 3/4" FPT CWS/HWS 3/4" CONDENSATE DRAIN DIFFUSER PLATE (SUPPLY/RETURN GRILLE NOT SHOWN) LEGEND CWR — CWS — FPT — HWR — HWS — Chilled Water Return Chilled Water Supply Female Pipe Thread Hot Water Return Hot Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 2-pipe arrangement.
カタログの6ページ目を開く
36IBAC 2 x 2, ALL-WAY BLOW, 4-PIPE UNIT DIMENSIONS FRONT VIEW RIGHT SIDE VIEW 4.00 DIFFUSER PLATE (SUPPLY/RETURN GRILLE NOT SHOWN) LEGEND CWR — CWS — FPT — HWR — HWS — Chilled Water Return Chilled Water Supply Female Pipe Thread Hot Water Return Hot Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 4-pipe arrange
カタログの7ページ目を開く
Dimensions (cont) 36IBAC 4 x 4, ALL-WAY BLOW, 2-PIPE UNIT DIMENSIONS LEFT SIDE VIEW FRONT VIEW HANGING BRACKET HANGING BRACKET a36-578 LEGEND FPT — Female Pipe Thread WR — Water Return WS — Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 2-pipe arrang
カタログの8ページ目を開く
36IBAC 4 x 4, ALL-WAY BLOW, 4-PIPE UNIT DIMENSIONS FRONT VIEW 8" 0 SUPPLY AIR LEFT SIDE VIEW TOP VIEW 35.95 LEGEND NOTES: CWR - Chilled Water Return 1 D'mensio"s sh°r .in inches CWS — Chilled Water Supply 2 Drawing sh°ws 4-pipe arrangement. FPT — Female Pipe Thread
カタログの9ページ目を開く
Dimensions (cont) 36IBAS 2 x 2, 1-WAY BLOW, 2-PIPE LH UNIT DIMENSIONS 1/2" O.D. HWS/CWS 9.82 3/4" CPVC DRAIN CONNECTION RIGHT SIDE VIEW LEFT SIDE VIEW Chilled Water Return Chilled Water Supply Hot Water Return Hot Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 2-pipe arrangement, left-hand piping connection; right hand connection would be opposite. 3. Hand is determined by standing on the front side of the unit with the supply air blowing against the back of your head. 4. Front face of the unit is determined by the nozzle side (supply air) side of the
カタログの10ページ目を開く
36IBAS 2 x 2, 1-WAY BLOW, 4-PIPE, LH UNIT DIMENSIONS REAR VIEW .88 1/2" O.D. CWS 9.82 3/4" CPVC DRAIN CONNECTION RIGHT SIDE VIEW LEFT SIDE VIEW Chilled Water Return Chilled Water Supply Hot Water Return Hot Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 4-pipe arrangement, left-hand piping connection; right hand connection would be opposite. 3. CW piping connection determines the hand of the unit. 4. Hand is determined by standing on the front side of the unit with the supply air blowing against the back of your head. 5. Front face of the unit is determined by the...
カタログの11ページ目を開く
Dimensions (cont)36IBAN 2 x 4, 1-WAY BLOW, 2-PIPE, LH UNIT DIMENSIONS FRONT VIEW HANGING BRACKET LEFT SIDE VIEW BOTTOM VIEW SUPPLY AND RETURN FACE SHOWN LEGEND CWR — Chilled Water Return CWS — Chilled Water Supply FPT — Female Pipe Thread HWR — Hot Water Return HWS — Hot Water Supply 1. Dimensions shown in inches. 2. Drawing shows 2-pipe arrangement, left-hand piping connection; right hand connection would be opposite. 3. CW piping connection determines the hand of the unit. 4. Hand is determined by standing on the front side of the unit with the supply air blowing against the back of your...
カタログの12ページ目を開く
36IBAN 2 x 4, 1-WAY BLOW, 4-PIPE, LH UNIT DIMENSIONS FRONT VIEW 1/2" Ø HANGING HOLES TYPICAL OF 4 RIGHT SIDE VIEW Chilled Water Return Chilled Water Supply Female Pipe Thread Hot Water Return Hot Water Supply NOTES: 1. Dimensions shown in inches. 2. Drawing shows 4-pipe arrangement, left-hand piping connection; right hand connection would be opposite. 3. CW piping connection determines the hand of the unit. 4. Hand is determined by standing on the front side of the unit with the supply air blowing against the back of your head. 5. Front face of the unit is determined by the nozzle side...
カタログの13ページ目を開く
36IBAN 1 x 4, 1-WAY BLOW, 2-PIPE, RH UNIT DIMENSIONS REAR VIEW LEFT SIDE VIEW LEGEND — Female Pipe Thread — Water Return — Water Supply SUPPLY/RETURN GRILLE WITH OPTIONAL LOUVERED SUPPLY AND RETURN FACE SHOWN a36-573 NOTES: 1. Dimensions shown in inches. 2. Drawing shows 2-pipe arrangement, right-hand piping connection; left hand connection would be opposite. 3. Hand is determined by standing on the front side of the unit with the supply air blowing against the back of your head. 4. Front face of the unit is determined by the nozzle side (supply air) side of the u
カタログの14ページ目を開くCarrier| Commercial Systems North Americaのすべてのカタログと技術パンフレット
-
WeatherMaker® 50TCQ
116 ページ
-
INFINITY™ 38MPRA
2 ページ
-
ActivAIR™ 36CB
24 ページ
-
Axis™
2 ページ
-
AHUBuilder
2 ページ
-
PERFORMANCE™ 50VL-A
6 ページ
-
50ZPB
4 ページ
-
PERFORMANCE™ 50VT-A
6 ページ
-
39CC
2 ページ
-
A World of Comfort
2 ページ
-
48P WEATHERMASTER®
168 ページ
-
48A WEATHERMAKER®
116 ページ
-
48PG CENTURION?
107 ページ
-
48PM CENTURION?
64 ページ
-
48TC WEATHERMAKER®
116 ページ
-
48HC WEATHERMASTER®
124 ページ
-
48LC WEATHEREXPERT®
52 ページ
-
48VL Performance? 14
32 ページ
-
48XL-A
30 ページ
-
48XL Infinity? 15
26 ページ
-
OMNIZONE?
80 ページ
-
16TJ
32 ページ
-
AQUAFORCE® 30XW150-400
60 ページ
-
EVERGREEN® 23XRV
32 ページ
-
AQUAFORCE® 30XA
150 ページ
-
30RB AQUASNAP®
92 ページ
-
30RAP AQUASNAP®
88 ページ
-
39S
36 ページ
-
39L AERO®
52 ページ
-
39M AERO®
110 ページ
-
19XR EVERGREEN®
56 ページ