
カタログの抜粋

What does HVAC equipment have to do with Earthquakes or Special Seismic Compliance? Hospitals, schools, governments, emergency shelters, public places, etc. across the country are being required to comply with special seismic requirements. This seismic requirement includes the equipment in the building, not just the structure to achieve special seismic certification. WHAT CHANGED? Previously, manufacturers would provide calculations as proof that equipment would maintain operation after a seismic event. Newer codes require equipment must be tested on a “shake table” in a lab. WHAT AGENCY OR CODE REGULATES THIS TESTING? ICC Evaluation Service, Inc., a non-profit organization has developed a test plan known as AC156 – Acceptance Criteria for Special Seismic Qualification by Shake Table Testing of Nonstructural Components & System which is acceptable to IBC, UBC and other local building code governing agencies. Carrier’s water-cooled chillers (19XR(V), 23XRV, 30HX and 30MP) and air-cooled chillers (30XA, 30RB, 30RAP) and split systems (38AP/09DP), product families are special seismic compliant. FEATURES – • Products tested on a shake table, simulating seismic effects as per AC-156 requirements as required by ICC Evaluation Service, Inc. • Certificate of Compliance or OSHPD pre-approval documentations are available at the time of specification and submittals • Seismic kit is provided along with the equipment for ground or roof installation • Consultant and Owner know that the equipment was certified for seismic events by an independent third party HOW CAN I GUARANTEE THAT THE EQUIPMENT MEETS AC-156 SEISMIC QUALIFICATION? YOU CAN SPECIFY THE FOLLOWING: • Manufacturer shall provide pre-approved documentation from OSHPD • Manufacturer shall provide seismic certificate of compliance • Manufacturer shall have performed seismic testing (shake table test) of specified model family as per ICC-ES AC-156 by recognized/ accredited third party approving agency For your next project requiring special seismic certification, contact your local Carrier sales engineer for more information. *Meets IBC 2006, ASCE-7-05, CBC 2007 and OSHPD seismic requirements. Seismically Certified Products (Water-Cooled Chillers) Seismically Certified Products (Air-Cooled Chillers and Split Systems) AquaEdgeTM 19XR(V) Two-Stage Water-Cooled Centrifugal Chillers AquaForce® 30XA Air-Cooled Screw Chillers AquaEdgeTM 19XR(V) Single-Stage Water-Cooled Centrifugal Chillers AquaSnap® 30RB Air-Cooled Scroll Chillers AquaSnap® 30RAP Air-Cooled Scroll Chillers AquaEdgeTM 23XRV Water-Cooled Screw Chillers AquaForce® 30HX Water-Cooled Screw Chillers AquaForce® 30XA Air-Cooled Screw Chillers with Greenspeed® Intelligence AquaSnap® 30MP Water-Cooled Scroll Chillers AquaSnap® 30RB Air-Cooled Scroll Chillers with Greenspeed® Intelligence Gemini® Select 38AP / 09DP Split Systems © Carrier Corporation 2015 04-811-50040 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs, without notice an
カタログの1ページ目を開くCarrier| Commercial Systems North Americaのすべてのカタログと技術パンフレット
-
WeatherMaker® 50TCQ
116 ページ
-
INFINITY™ 38MPRA
2 ページ
-
ActivAIR™ 36CB
24 ページ
-
ACTIVAIR™ 36IB
44 ページ
-
Axis™
2 ページ
-
AHUBuilder
2 ページ
-
PERFORMANCE™ 50VL-A
6 ページ
-
50ZPB
4 ページ
-
PERFORMANCE™ 50VT-A
6 ページ
-
39CC
2 ページ
-
A World of Comfort
2 ページ
-
48P WEATHERMASTER®
168 ページ
-
48A WEATHERMAKER®
116 ページ
-
48PG CENTURION?
107 ページ
-
48PM CENTURION?
64 ページ
-
48TC WEATHERMAKER®
116 ページ
-
48HC WEATHERMASTER®
124 ページ
-
48LC WEATHEREXPERT®
52 ページ
-
48VL Performance? 14
32 ページ
-
48XL-A
30 ページ
-
48XL Infinity? 15
26 ページ
-
OMNIZONE?
80 ページ
-
16TJ
32 ページ
-
AQUAFORCE® 30XW150-400
60 ページ
-
EVERGREEN® 23XRV
32 ページ
-
AQUAFORCE® 30XA
150 ページ
-
30RB AQUASNAP®
92 ページ
-
30RAP AQUASNAP®
88 ページ
-
39S
36 ページ
-
39L AERO®
52 ページ
-
39M AERO®
110 ページ
-
19XR EVERGREEN®
56 ページ