Product Data WeatherMaker® Single Packaged Rooftop Heat Pump Units 6 to 12.5 Nominal Tons 50TCQ*07, 08, 12, 14 Electric Cooling Rooftop Units with Heat Pump and Optional Electric Heat with Puron® (R-410A) Refrigerant © 2019 Carrier Corporation Form 50TCQ-7-14-02PD

カタログの1ページ目を開く
WeatherMaker® 50TCQ - 2

Features/Benefits The Carrier Packaged Heat Pump rooftop unit (RTU) was designed by customers for customers. With no-strip screw collars, handled access panels, and more, we’ve made your unit easy to install, easy to maintain and easy to use. Easy to install All WeatherMaker® units are field-convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Carrier 6 to 12.5 ton 50TCQ rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier...

カタログの2ページ目を開く
WeatherMaker® 50TCQ - 3

Model number nomenclature Staged Air Volume (SAV™) fan speed system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on single stage cooling model 07 and 2-stage cooling models, 08-14 with electro-mechanical controls or RTU Open controller. Note that SAV is required on all units for installation in the United States as per the Department of Energy (DOE) efficiency standard of 2018. Series - WeatherMaker® 50TC - Packaged Rooftop Refrig. Systems Options A = One Stage Cooling Models D = Two Stage Cooling Models...

カタログの3ページ目を開く
WeatherMaker® 50TCQ - 4

AHRI RATINGS - COOLING MODE 50TCQ LEGEND AHRI ASHRAE COP EER IECC IEER Air-Conditioning, Heating and Refrigeration Institute American Society of Heating, Refrigerating and AirConditioning Engineers Coefficient of Performance Energy Efficiency Ratio International Energy Conservation Code Integrated Energy Efficiency Ratio 1. Rated and certified under AHRI Standard 210/240 or 340/360, as appropriate. 2. Ratings are based on: Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F db outdoor air temp. IEER Standard: A measure that expresses cooling part-load EER efficiency...

カタログの4ページ目を開く
WeatherMaker® 50TCQ - 5

MINIMUM - MAXIMUM AIRFLOWS (CFM) COOLING AND ELECTRIC HEAT 50TCQ UNIT ‘Minimum electric heat CFM exceptions (see table below): LEGEND dB — Decibel NOTES: 1. Outdoor sound data is measured in accordance with AHRI standard 270. 2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure accounts for specific environmental factors which do not match individual applications. Sound power values are independent of the environment and therefore more accurate. A-weighted sound ratings filter out very high and very low...

カタログの5ページ目を開く
WeatherMaker® 50TCQ - 8

Options and accessoriesFACTORY-INSTALLED OPTIONS AND FIELD-INSTALLED ACCESSORIES CATEGORY 2. Requires a field-supplied 24V transformer for each application. See price pages for details. 3. FDD (Fault Detection and Diagnostic) capability per California Title 24 section 120.2. 4. Models with RTU Open DDC controls comply with California Title 24 Fault Detection and Diagnostic (FDD). PremierLink is not FDD. 5. Included with economizer. 6. Sensors for optimizing economizer performance. 7. SAV is required on all units for installation in the United States as per the Department of Energy (DOE)...

カタログの8ページ目を開く
WeatherMaker® 50TCQ - 9

Power Exhaust Pressure Relief Economizers can reduce operating costs. They bring in fresh, outside air for ventilation; and provide cool, outside air to cool your building. This is the preferred method of low ambient cooling. When coupled to CO2 sensors, economizers can limit the ventilation air to only that amount required. Economizers are available, installed and tested by the factory, with either enthalpy or dry bulb temperature inputs. There are also models for electro-mechanical as well as direct digital controllers. Additional sensors are available as accessories to optimize the...

カタログの9ページ目を開く
WeatherMaker® 50TCQ - 10

IMPORTANT: Data based on 0.10 ($/kWh) in an office application utilizing Carrier’s HAP 4.6 simulation software program. Compared to single speed indoor fan motor systems, Carrier’s SAV system can save substantial energy, 25%+, versus single speed indoor fan motor systems. The VFD used in Carrier’s SAV system has soft start capabilities to slowly ramp up the speeds, thus eliminating any high inrush air volume during initial start-up. It also has internal over current protection for the fan motor and a field-installed display kit that allows adjustment and in depth diagnostics of the VFD....

カタログの10ページ目を開く
WeatherMaker® 50TCQ - 11

NOTE: Where multiple variations are available, the heaviest combination is listed.

カタログの11ページ目を開く
WeatherMaker® 50TCQ - 12

DIMENSIONS OF 50TCQ*07 UNITS BUILT ON AND AFTER 4/15/2019 Base unit dimensions

カタログの12ページ目を開く
WeatherMaker® 50TCQ - 14

50TCQ*07 CORNER WEIGHTS AND CLEARANCES Base unit dimensions (cont)

カタログの14ページ目を開く
WeatherMaker® 50TCQ - 15

50TCQ*07 BASE RAIL DETAILS

カタログの15ページ目を開く
WeatherMaker® 50TCQ - 16

Base unit dimensions (cont)

カタログの16ページ目を開く
WeatherMaker® 50TCQ - 18

50TCQ*08-09 UNIT DIMENSIONS (cont) Base unit dimensions (cont)

カタログの18ページ目を開く
WeatherMaker® 50TCQ - 19

CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 ft (3 m) of unit fresh air intake hood Side condensate drain is used Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) NOTE: Unit not designed to...

カタログの19ページ目を開く
WeatherMaker® 50TCQ - 20

Base unit dimensions (cont)

カタログの20ページ目を開く
WeatherMaker® 50TCQ - 21

50TCQ*12 UNIT DIMENSIONS (cont)

カタログの21ページ目を開く
WeatherMaker® 50TCQ - 22

Base unit dimensions (cont) 50TCQ*12 SERVICE CLEARANCES CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) Check for sources of flue products within 10 ft (3 m) of unit fresh air intake hood Side condensate drain is used Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically...

カタログの22ページ目を開く

Carrier| Commercial Systems North Americaのすべてのカタログと技術パンフレット

  1. INFINITY™ 38MPRA

    2 ページ

  2. ActivAIR™ 36CB

    24 ページ

  3. ACTIVAIR™ 36IB

    44 ページ

  4. Axis™

    2 ページ

  5. AHUBuilder

    2 ページ

  6. 50ZPB

    4 ページ

  7. 39CC

    2 ページ

  8. A World of Comfort

    2 ページ

  9. 48P WEATHERMASTER®

    168 ページ

  10. 48A WEATHERMAKER®

    116 ページ

  11. 48PG CENTURION?

    107 ページ

  12. 48PM CENTURION?

    64 ページ

  13. 48TC WEATHERMAKER®

    116 ページ

  14. 48HC WEATHERMASTER®

    124 ページ

  15. 48LC WEATHEREXPERT®

    52 ページ

  16. 48VL Performance? 14

    32 ページ

  17. 48XL-A

    30 ページ

  18. 48XL Infinity? 15

    26 ページ

  19. OMNIZONE?

    80 ページ

  20. 16TJ

    32 ページ

  21. EVERGREEN® 23XRV

    32 ページ

  22. AQUAFORCE® 30XA

    150 ページ

  23. 30RB AQUASNAP®

    92 ページ

  24. 30RAP AQUASNAP®

    88 ページ

  25. 39S

    36 ページ

  26. 39L AERO®

    52 ページ

  27. 39M AERO®

    110 ページ

  28. 19XR EVERGREEN®

    56 ページ

カタログアーカイブ