Physician’s pocket reference guide - 1

Physician’s pocket reference guide de Indications for use n Component ordering information Introduction system information Graft specifications ENDOVASCULAR GRAFTS Accessory produc

カタログの1ページ目を開く
Physician’s pocket reference guide - 3

Please refer to the IFUs for complete instructions. Additional information may be found at www.cookmedical.c

カタログの3ページ目を開く
Physician’s pocket reference guide - 4

Expect Zenith® precision.

カタログの4ページ目を開く
Physician’s pocket reference guide - 5

Indications for use Length Aortic fixation site diameter Angulation/ Curvature Patients with abdominal aortic or aortoiliac aneurysms having morphology suitable for endovascular repair ≥ 15 mm nonaneurysmal infrarenal neck 18–32 mm (measured outer wall to outer wall) • Angle < 60 degrees relative to the long axis of the aneurysm • Angle < 45 degrees relative to the axis of the suprarenal aorta Distal fixation site > 10 mm in length and 7.5–20 mm in diameter (measured outer wall to outer wall) Contralateral iliac fixation site Distal fixation site > 10 mm in length and 7.5–20 mm in diameter...

カタログの5ページ目を開く
Physician’s pocket reference guide - 6

Bifurcated main body grafts Order Number Reference Part Number Main Body Diameter mm Main Body Contralateral Length mm Introducer Sheath ID/OD Fr (mm)/mm Main body Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

カタログの6ページ目を開く
Physician’s pocket reference guide - 7

Bifurcated main body grafts (continued) Order Number Reference Part Number Main Body Diameter mm Main Body Contralateral Length mm Introducer Sheath ID/OD Fr (mm)/mm H&L-B One Shot® Introduction System for main body grafts 22-32 mm grafts: 16 Fr (5.3 mm) ID/6.0 mm OD Main body Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

カタログの7ページ目を開く
Physician’s pocket reference guide - 8

Main body ZALB-XX-YY ZALB-(main body diameter)-(main body contralateral length) Note: All measurements are in millimetres. The black numbers on the illustrations indicate stent lengths. The red numbers indicate gap lengths. Gap lengths are approximate. Contralateral and ipsilateral iliac legs: Refer to pages 50-56 of this pocket guide for Spiral-Z AAA Iliac Leg Grafts.

カタログの8ページ目を開く
Physician’s pocket reference guide - 9

Ancillary components Order Number Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Main Body Extensions G51995 ZLBE-22-45 Introducer Sheath ID/OD Fr (mm)/mm Order Number Reference Part Number Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. H&L-B One-Shot® Introduction System for ancillary components

カタログの9ページ目を開く
Physician’s pocket reference guide - 10

Main body extensions ZLBE-XX-YY Converters ZLC-XX-YY ZLC-(proximal diameter)-(length) Note: All measurements are in millimetres. The black numbers on the illustrations indicate stent lengths.

カタログの10ページ目を開く
Physician’s pocket reference guide - 11

MAIN BODY PLACEMENT Note: Before insertion, position main body delivery system on patient’s abdomen under fluoroscopy to determine the orientation of the contralateral limb radiopaque marker. Insert main body delivery system over the wire, into the femoral artery. Advance delivery system until the four gold radiopaque markers (which are positioned 2 mm from the most proximal segment of the graft material) are just inferior to the most inferior renal orifice. Deploy the first two covered stents by withdrawing the sheath while monitoring device location. Check position of the contralateral limb...

カタログの11ページ目を開く
Physician’s pocket reference guide - 12

Deployment overview (continued) pulling on the inner cannula. Leave the sheath and wire guide in place. Note: Maintain position of sheath and wire guide. Close the Captor® Hemostatic Valve on the Flexor® Introducer Sheath. IPSILATERAL ILIAC LEG PLACEMENT AND DEPLOYMENT Prior to removing the main body sheath, inject contrast media through the sheath to locate the ipsilateral internal iliac artery. Remove the main body sheath. Introduce the ipsilateral iliac leg delivery system, and continue advancing it slowly until the proximal edge of the ipsilateral leg graft aligns with the proximal edge...

カタログの12ページ目を開く
Physician’s pocket reference guide - 13

proven migration Zenith Flex

カタログの13ページ目を開く
Physician’s pocket reference guide - 14

7.5-20 mm Compatible with required introduction systems Indications for use Length Aortic fixation site diameter Angulation/ Curvature Patients with abdominal aortic or aortoiliac aneurysms having morphology suitable for endovascular repair ≥ 15 mm nonaneurysmal infrarenal neck 18–32 mm (measured outer wall to outer wall) • Angle < 60 degrees relative to the long axis of the aneurysm • Angle < 45 degrees relative to the axis of the suprarenal aorta Distal fixation site > 10 mm in length and 7.5–20 mm in diameter (measured outer wall to outer wall) Contralateral iliac fixation site Ipsilateral...

カタログの14ページ目を開く
Physician’s pocket reference guide - 15

Bifurcated main body grafts Order Number Reference Part Number Main Body Diameter mm Introducer Main Body Sheath Contralateral ID/OD Length Fr (mm)/mm mm Main body Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

カタログの15ページ目を開く
Physician’s pocket reference guide - 16

Bifurcated main body grafts (continued) Aortic Main Main Body Introducer Vessel Body Contralateral Sheath Order Reference OD Diameter Length ID/OD Number Part Number mm mm mm Fr(mm)/mm Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details. Z-Trak* Introduction System for main body grafts

カタログの16ページ目を開く
Physician’s pocket reference guide - 17

Note: Ipsilateral and contralateral limb diameters on all 22 mm diameter main body grafts are 11 mm. TFFB-(main body diameter)-(main body contralateral length)-ZT Note: All measurements are in millimetres. The black numbers on the illustrations indicate stent lengths. The red numbers indicate gap lengths. Gap lengths are approximate. Contralateral and ipsilateral iliac legs: Refer to pages 50-56 of this pocket guide for Spiral-Z AAA Iliac Leg Grafts. Main body

カタログの17ページ目を開く
Physician’s pocket reference guide - 18

Bifurcated main body grafts (continued) 36 mm Main body

カタログの18ページ目を開く
Physician’s pocket reference guide - 19

Ancillary components Order Number Reference Part Number Main Body Extensions G55204 ESBE-22-39-ZT Introducer Sheath ID/OD Fr (mm)/mm Order Number Reference Part Number Introducer Sheath ID/OD Fr (mm)/mm Introducer Sheath ID/OD Fr (mm)/mm Order Number Reference Part Number Some products or part numbers may not be available in all markets. Contact your local Cook representative or Customer Service for details.

カタログの19ページ目を開く

COOK Medicalのすべてのカタログと技術パンフレット

  1. LITHO-60

    16 ページ

  2. Litho 100

    16 ページ

  3. Physician’s

    92 ページ

  4. HiWire

    2 ページ

  5. EUS 3 Needle

    12 ページ

  6. Surgical Melker

    2 ページ

  7. Beacon Tip

    4 ページ

  8. Royal Flush Plus

    4 ページ

  9. Fusion ® Zilver

    2 ページ

  10. BENCHTOP INCUBATOR

    4 ページ

  11. FISTULA BRUSH

    2 ページ

  12. Fusion ®

    2 ページ

  13. Zenith

    2 ページ

  14. EchoTip®

    2 ページ

  15. Hercules ®

    2 ページ

  16. Biodesign®

    2 ページ

カタログアーカイブ

  1. Hemostasis Family

    6 ページ