カタログの抜粋
Functional safe zone Every patient moves of pelvic rotation through functional activities should be accounted for with total hip replacement. Pelvic tilt been shown to be as great implant. No safe zone has ever accounted for this. OPS™ is designed to optimally orientate a cup within a safe zone, and for the cup to remain within that safe zone as the pelvis rotates throughout functional activity.
カタログの2ページ目を開くThe arc of pelvic motion has been shown to be as great as 70° through sit to stand activities1 – DiGioia CORR 2006
カタログの3ページ目を開くOverview Every patient moves differently1 and their total hip replacement should be optimised to account for this. The orientation of the acetabular cup is one of the most important factors under the surgeon’s control4, and acetabular cup orientation has a significant effect on device performance, including patient outcomes, impingement, edge loading, bearing wear, osteolysis and loosening5,6. There remains two key issues with THR today: 1 What is the target for a that orientation? 1 Implant orientation Clinical issue Safe zones Pelvic tilt There have been various attempts to define a ‘safe...
カタログの4ページ目を開く2 Delivery Clinical issue Intra-operative tools It is inherently difficult to position the cup during surgery and achieving a target position is a considerable challenge in THR. It has been shown that up to 50% of surgeries miss the intended orientation13 and the chance of hitting a target to within 5° can be as low as 21.5%14. Clinical solution How is the optimised position delivered during surgery? Once the target orientation for a specific patient has been decided, a unique guide is produced for the individual. The planned orientation is built into the axis of the guide which is used...
カタログの5ページ目を開くDiGioia AM, Hafez MA, Jaramaz B, Levison TJ, Moody JE, Functional pelvic orientation measured from lateral standing and sitting radiographs. Clin Orthop Relat Res 453:272–276 Ishida T, Inaba Y, Kobayashi N, Iwamoto N, Yukizawa Y, Choe H, Saito T. Changes in pelvic tilt following total hip arthroplasty. Journal of Orthopaedic Science. 2011; 682-688 Au J, Perriman DM, Neeman TM, Smith PN. Standing or supine x-rays after total hip replacement - when is the safe zone not safe? Hip International. 2014 Echeverri S, Leyvraz P, Zambelli P, et al. Reliable acetabular cup orientation with a new...
カタログの6ページ目を開くCorinのすべてのカタログと技術パンフレット
-
2019 Revival™ 100mm
2 ページ
-
Revival™
2 ページ
-
2019 TriFit TS™
2 ページ
-
Evidence base
8 ページ
-
Dynacup™
6 ページ
-
Dual Mobility™
4 ページ
-
Meije Duo™
4 ページ
-
Linea™
4 ページ
-
Dynacup One-C™
4 ページ
-
clinical excellence
6 ページ
-
Revival™
6 ページ
-
ECiMa™
12 ページ
-
LARS™
6 ページ
-
Solomax™
4 ページ
-
Zenith™
12 ページ
-
Rotaglide+™
12 ページ
-
MetaFix™
12 ページ
-
TriFit TS™
12 ページ
-
Uniglide™
28 ページ
-
Unity KneeTM
16 ページ
-
Hip continuum
6 ページ
-
TriFit TS?
12 ページ
-
LARS ACL
12 ページ
-
LARS
8 ページ
-
Solomax
4 ページ
-
Zenith
12 ページ
-
Uniglide
12 ページ
-
Rotaglide+
12 ページ
-
Trinity
12 ページ