1. Extraction Drill > The Extraction Drill is composed of three types of Drills (Ø1.3 / Ø1.7 / Ø2.1) that can be selected according to the case. > Used for the immediate and effortless extraction of the root of the tooth with simple procedures. A root extraction can be done regardless of whether residual amount of root is large or small. > The Extraction Screw is fastened into the hole that was created by the Extraction Drill via the Screw method, and it is stably fixed to the remaining root. It is composed of the Ø1.8 / Ø2.2 / Ø2.6 Screws that can be selected according to the Extraction...
カタログの2ページ目を開く
> After connecting the Post Driver to the Extraction Screw, turn the Torque Wrench in a clockwise direction in order to fix it to the > The Elevator is used by connecting it with the Torque Head and extracting the root by applying force toward a distal or mesial hole that was created by the Extraction Drill (recommended torque : 30 N.cm or more). * Connect to the Extraction Screw 4. Rest Plate > The Rest Plate is connected between the Extraction Screw and the Torque Head. It protects the part with silicon that comes into direct contact with the adjacent teeth in order to prevent teeth...
カタログの3ページ目を開く
* Drilling Sequence Root Canal Preparation 4. Torque Head Connect the Torque Head to the Extraction Screw projected above the Rest Plate by rotating it clockwise. #1 Canal filling Gate drills Atraumatic Extraction kit Connect Torque Head to Screw 5. Torque Wrench Under 20 N.cm Extract the tooth by rotating the Torque Head clockwise using the Torque Wrench. - Fix the screw with a torque of 20~25 N.cm. If it is not applied, use a thicker Screw. - The low torque force causes the Screw to fall out during the extraction, and the over torque force fractures tooth root. Extraction Root After...
カタログの4ページ目を開く
- If there are adjacent teeth with 2 or higher swaying degrees, upward pulling or downward pressing should be applied using the Elevator so that the teeth will not receive force during extraction. - If there is an adjacent tooth projected to the mesiodistal root, it must be extracted using the Elevator.
カタログの5ページ目を開く
Cowellmedi Co.,Ltd Floor 6, Blue Fin Tower, 42, Seochojungang-ro,Seocho-gu, Seoul, Korea Tel. +82-2-3453-5085 Fax. +82-2-3453-5086 E-mail. cib@cowellmedi.com Cowellmedi USA INC 218 Trianon LN Villanova PA 19085-1442 USA Tel. 1-623-939-1344 Fax. 1-623-939-1472 Cowell R&D Institute 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 46986, Korea Tel. +82-51-314-2028 Fax. +82-51-314-2026
カタログの6ページ目を開くCowellmediのすべてのカタログと技術パンフレット
-
InnoGenic™ Wifi-Mesh
26 ページ
-
Diaderm® M
3 ページ
-
MEGA DERM™ Plus
3 ページ
-
DIABONE
3 ページ
-
INNO-CaP
3 ページ
-
COWELL® BMP
6 ページ
-
AO4 Surgical Stent
3 ページ
-
InnoGenic™ GBR Kit
7 ページ
-
Sinus Lift Kit
5 ページ
-
COWELL® Digital Products
39 ページ
-
Surgical Kit
11 ページ
-
SONATOR™ 80’s
16 ページ
-
Multi S & A Abutment
20 ページ
-
Beauty-up™ Abutment
31 ページ
-
Ball Abutment System
15 ページ
-
Mini Plus® Implant
5 ページ
-
INNO Internal Impant
12 ページ
-
INNO Submerged Implant
18 ページ
-
COWELL® Implant System
66 ページ