カタログの抜粋

InnoFit® Lodestar Kit Universal to any implant system.
カタログの1ページ目を開く
> A cost-effective guided surgery solution applicable to various types of clinical cases. > Universal to any implant system. Ø2.0 X 7 Abut. Profile Drill KLSPD10 KLSPD12S KLSPD14
カタログの2ページ目を開く
Tissue Punch > The gingiva in the position where the implant is to be placed can be incised in a circular shape, Pilot Drill and it can also be used in inclined bones (50 rpm without irrigation). The gingiva can be incised in a circular shape although bone level is inclined or not parallel. The internal cutting edge of the Tissue Punch cuts the gingiva into small pieces so that those can be removed by suction without extra work. Initial Drill > The Drill combined with Bone Flattening Drill and Point Drill which no separate Bone Flattening Drill is required provides simper procedure and...
カタログの3ページ目を開く
Abutment Profile * Offset length setting > Used for elimination of the alveolar bone that interferes with the accurate connection of abutment. - The basic length from the fixture platform to the top of the Sleeve is 10mm. - In case that gingival is thick or fixture needs to be placed deeper due to low bone density, use the Sleeve 2 or 4mm upright to the top. - The higher offset value, the less accurate it will be, so use 10mm if possible. KLSPD10 * Mount Stopper on the 14mm Drill to use as the 12mm Drill. * Remove residual bone by rotating and drilling 360° along the inside of the Sleeve....
カタログの4ページ目を開く
> These products are optional as extra ones which are not included in the kit. Guide Reamer Used for precise contact of Drill and Sleeve (Sleeve / Non Sleeve). Use the 4.5mm Guide Reamer for Non Sleeve, and the 5.3 Guide Reamer for Sleeve (800 rpm without irrigation). Guide Reamer (Non Sleeve) Open Sleeve * Packing Unit : 5 Sleeves * Packing Unit : 5 Sleeves Hex-directional identification groove. Closed Sleeve Guide Reamer (Sleeve) Ø4.5 Below (Imprecise hole after the guided template fabrication) Revises imprecisely formed hole after the guided template fabrication using the 4.5 Guide...
カタログの5ページ目を開く
* The 14mm Drill must be used after using the 10mm Drill to enable Sleeve contact For the use of the 14mm Drill with exact contact to the Sleeve, use the Ø2.0x10mm Drill first before using the 14mm Drill. Drilling Sequence e.g.) 3.4 X 14mm Drilling Sequence Initial Drill Protocol (Non Sleeve) Reamer (Ø4.5) Final drill of each system Final drill of each system 10 With the guided template mounted * Drilling method With the guided template mounted After removal of the guided template - Make sure with drilling in a desired direction without a change in path through the primary Drill contact (A)...
カタログの6ページ目を開く
Cowellmedi Co.,Ltd Floor 6, Blue Fin Tower, 42, Seochojungang-ro,Seocho-gu, Seoul, Korea Tel. +82-2-3453-5085 Fax. +82-2-3453-5086 E-mail. cib@cowellmedi.com Cowellmedi USA INC 218 Trianon LN Villanova PA 19085-1442 USA Tel. 1-623-939-1344 Fax. 1-623-939-1472 Cowell R&D Institute 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 46986, Korea Tel. +82-51-314-2028 Fax. +82-51-314-2026
カタログの7ページ目を開くCowellmediのすべてのカタログと技術パンフレット
-
InnoGenic™ Wifi-Mesh
26 ページ
-
Diaderm® M
3 ページ
-
MEGA DERM™ Plus
3 ページ
-
DIABONE
3 ページ
-
INNO-CaP
3 ページ
-
COWELL® BMP
6 ページ
-
AO4 Surgical Stent
3 ページ
-
InnoGenic™ GBR Kit
7 ページ
-
Sinus Lift Kit
5 ページ
-
COWELL® Digital Products
39 ページ
-
Surgical Kit
11 ページ
-
SONATOR™ 80’s
16 ページ
-
Multi S & A Abutment
20 ページ
-
Beauty-up™ Abutment
31 ページ
-
Ball Abutment System
15 ページ
-
Mini Plus® Implant
5 ページ
-
INNO Internal Impant
12 ページ
-
INNO Submerged Implant
18 ページ
-
COWELL® Implant System
66 ページ