2.0 mm LCP® Distal Ulna Plate
1 / 20ページ

{{requestButtons}}

カタログの抜粋

2.0 mm LCP®  Distal Ulna Plate - 1

For Capital and Subcapital Fractures of the Ulna 2.0 mm LCP Distal Ulna Plate ® Surgical Technique

カタログの1ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 3

2.0 mm LCP Distal Ulna Plate Surgical Technique Clinical Examples Approach Reduce Fracture and Position Plate Adjust Length and Complete Fixation Closure Implant Removal Product Information Implants Instruments MR Information The 2.0 mm LCP Distal Ulna Plate System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the 2.0 mm LCP Distal Ulna Plate System in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. Image...

カタログの3ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 4

2.0 mm LCP® Distal Ulna Plate. For capital and subcapital fractures of the ulna. The distal ulna is an essential component of the distal radioulnar joint, which helps provide rotation to the forearm. The distal ulnar surface is also an important platform for stability of the carpus and, beyond it, the hand. Unstable fractures of the distal ulna therefore threaten both movement and stability of the wrist. The size and shape of the distal ulna, combined with the overlying mobile soft tissues, make application of standard implants difficult. The 2.0 mm LCP® Distal Ulna Plate is specifically...

カタログの4ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 5

Narrow plate design, low screw -plate profile, rounded edges and polished surface are designed to minimize irritation of overlying soft tissue Pointed hooks grip the styloid process and provide a reference point for plate application Round locking holes in the head accept 2.0 mm locking screws Combi holes accept either 2.0 mm locking or cortex screws and allow locking or compression throughout the length of the plate shaft Angled locking screws securely hold the ulnar head 2.0 mm LCP® Distal Ulna Plate  Surgical Technique  DePuy Synthes

カタログの5ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 6

The 2.0 mm LCP Distal Ulna Plate is indicated for fixation of fractures, osteotomies, nonunions, replantations, and fusions of small bones and small bone fragments, particularly in osteopenic bone. 4    DePuy Synthes  2.0 mm LCP® Distal Ulna Plate  Surgical T

カタログの6ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 7

Clinical Examples Examples include: – Fractures of the ulnar head where the articular surface is either displaced, rotated, or tilted – Comminuted extra-articular fractures of the ulnar neck threatening stable congruency of the distal radioulnar joint Note: Not all fractures of the distal ulna require internal fixation. Many simple ulnar styloid fractures demand nothing more than symptomatic treatment. Displaced articular surface Rotated articular surface Tilted articular surface 2.0 mm LCP® Distal Ulna Plate  Surgical Technique  DePuy Synt

カタログの7ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 8

Modular Mini Fragment LCP Instruments and Implants Set Titanium LCP Modular Mini Fragment Instruments and Implants Set 1 Approach The ideal insertion site for this implant is located toward the ulnar styloid and between the flexor carpi ulnaris and extensor carpi ulnaris tendons. Make a longitudinal skin incision over the palpable ulna, taking care to avoid the dorsal sensory branch of the ulnar nerve, which crosses the bone at this level. Once the distal shaft of the ulna is visible, subperiosteal dissection will allow the fracture fragments to be visualized and reduced. Gently retract the...

カタログの8ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 9

Reduce Fracture and Position Plate 2 Contour plate (optional) Instrument 329.12 Bending Pliers, for 1.5 mm and 2.0 mm plates If necessary, contour the plate using the flat-nosed pliers. Notes – The plate holes have been designed to accept some degree of deformation. The undercut helps to ensure that the threaded holes will not be distorted with typical contouring. Significant distortion of the threaded holes will reduce locking effectiveness. – If possible, the plate should not be cut since the resulting sharp edges can irritate the overlying soft tissues. Precaution: The plate features...

カタログの9ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 10

Reduce Fracture and Position Plate 3. Reduce fracture and position plate continued In simple fractures of the ulnar neck, apply the plate to the subcutaneous border of the distal ulna, securing points of fixation in both the head and the shaft. Note: It may be necessary to temporarily stabilize the fracture with a transtyloid 1.1 mm guide wire. The wire should be inserted between the distal hooks of the temporarily applied plate. Precaution: The head of the distal ulna is often fragile. Caution should be exercised if using pointed reduction forceps, since the force of this instrument may...

カタログの10ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 11

4 Fix plate distally Instruments 310.507 mm Drill Bit with Depth Mark, mini quick 1.5 coupling, 96 mm 311.01 Handle, with mini quick coupling 2.0 mm Screwdriver Blade, self-retaining, StarDrive, short 2.0 mm Screwdriver Blade, self-retaining, StarDrive, long 319.006 Depth Gauge, for 2.0 mm and 2.4 mm cortex screws, measures up to 50 mm 323.034 mm Threaded Drill Guide, with depth 1.5 gauge Secure the drill guide in the desired hole. Predrill the hole with the 1.5 mm drill bit through the drill guide, and measure screw length directly from the gauge. Remove the drill bit and drill guide....

カタログの11ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 12

4. Fix plate distally continued Insert the appropriate length 2.0 mm locking screw. 11    DePuy Synthes  2.0 mm LCP® Distal Ulna Plate  Surgical T

カタログの12ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 13

Adjust Length and Complete Fixation 5 Adjust length and complete fixation Multiple options for screw insertion in the distal portion of the plate allow a wide range of fracture patterns to be securely stabilized. Option 1 In fractures which require length adjustment, place one or two 2.0 mm locking screws in the ulnar head to securely fix the implant distally. Place a 2.0 mm cortex screw in the oblong hole of the shaft, and obtain the correct length of reduction. Use a combination of cortex and locking screws in the surrounding holes to stabilize the fracture securely, as dictated by bone...

カタログの13ページ目を開く
2.0 mm LCP®  Distal Ulna Plate - 14

Adjust Length and Complete Fixation 5. Adjust length and complete fixation continued Option 3 Instrument 314.67.96** or 314.667* 1.5 mm/2.0 mm Cruciform Screwdriver Blade, with holding sleeve 1.5 mm Cruciform Screwdriver Blade, with spring holding sleeve, short In fractures where it is necessary to stabilize the tip of the ulnar styloid process, the distal plate hole is left empty. Remove the 1.1 mm wire, which was used for preliminary fixation (see note, Step 3). Overdrill the near fragment with a 1.5 mm drill bit. Insert a 1.5 mm cortex screw in lag mode between the arms of the distal...

カタログの14ページ目を開く

Depuy Synthesのすべてのカタログと技術パンフレット

  1. Building on Success

    16 ページ

  2. HEALIX ADVANCE

    4 ページ

  3. 3.5 mm LCP™ Medial

    15 ページ

カタログアーカイブ

  1. 2.4 mm VA LCP™

    4 ページ

  2. Power line II

    4 ページ

  3. Concorde

    28 ページ

  4. LCP Intercarpal

    31 ページ

  5. LCS® COMPLETE™

    2 ページ

  6. Synthes TPLO.

    8 ページ

  7. SynFix-LR System

    56 ページ

  8. CONDUIT™

    15 ページ

  9. Brochure_FINAL

    2 ページ

  10. DePuy Synthes

    81 ページ

  11. Anspach

    3 ページ

  12. Corail

    24 ページ

  13. S-ROM® NOILES™

    68 ページ

  14. Speed

    2 ページ

  15. attune

    80 ページ

  16. HAMMERLOCK® 2

    2 ページ

  17. Polar

    4 ページ

  18. Air Power Line II

    6 ページ

  19. TruMatch Pin Guides

    16 ページ

  20. P F N A

    8 ページ

  21. SKILL, DEDICATION,

    16 ページ

  22. DURALOC

    16 ページ

  23. MatrixNEURO

    8 ページ

  24. Anspach XMax

    4 ページ

  25. Air Pen Drive

    4 ページ

  26. Colibri II

    4 ページ

  27. Spine

    25 ページ

  28. TomoFix

    60 ページ

  29. Expert Tibia Nail

    84 ページ

  30. Sacral Bars

    16 ページ

  31. Pelvic C-Clamp

    20 ページ

  32. LCP

    24 ページ

  33. PFNA

    112 ページ

  34. HCS 1.5, 2.4, 3.0

    36 ページ

  35. LCP Wrist Fusion

    32 ページ

  36. LCP Compact Hand

    28 ページ

  37. VA-LCP Elbow

    48 ページ

  38. Distal Radius

    44 ページ

  39. Olecranon

    30 ページ

  40. LCP Hook Plate

    28 ページ

  41. DHP & Olecranon

    4 ページ

  42. LCP S-A

    4 ページ

  43. Epoca

    4 ページ

  44. Philos

    32 ページ

  45. MultiLoc

    68 ページ