Pelvic C-Clamp. Emergency stabili- zation instrument for unstable injuries and fractures of the pelvic ring. Technique Guide
カタログの1ページ目を開くIntroduction Pelvic C-Clamp 2 Product Information Implants and Instruments 14 O Image intensifier control This guide is not sufficient for an immediate application of the Pelvic C-Clamp. Instruction by an experienced surgeon in hand-ling the Pelvic C-Clamp is highly recommended.
カタログの3ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 2 Pelvic C-Clamp. Permits rapid reduction and stabilization of the posterior pelvic ring. Description The Pelvic C-Clamp is an emergency stablization instrument for unstable injuries and fractures of the pelvic ring. Unstable pelvic ring fractures can be associated with massive blood loss that can cause terminal shock. The Pelvic C-Clamp allows rapid reduction and stabilization of these unstable pelvic ring fractures. It is therefore an invaluable tool for gaining control of the shock reaction, while neither delaying nor hindering...
カタログの4ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 3 In cases of sacral fractures or disruptions of the sacroiliac joint, there is often concomitant blood loss from the fracture surface and from the veins of the presacral plexus. The use of the Pelvic C-Clamp in those settings can save lives. Direct transverse compression of the sacroiliac joint controls bleeding from the fracture surfaces and from the presacral plexus. With the Pelvic C-Clamp applied, there is still adequate access for a laporotomy or tamponade. Inner rail Outer rail Upper arm Lower arm Threaded tube Cannulated...
カタログの5ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Indications The Pelvic C-Clamp is intended for emergency stabilization of sacrum fractures or disruptions of the sacroiliac joint with associated circulatory instability. Caution: Avoid use where: – Fractures of the ilium are present as there is risk of pin perforation through the fracture line – There are comminuted sacral fractures with the risk of compression of the sacral nerve plexus Note: In life threatening situations hemorrhage control takes priority over the potential risk of nerve root compression. 4 Synthes Pelvic C-Clamp...
カタログの6ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 5 Surgical Technique 1 Pre-operative preparation Instrument 01.306.000 Pelvic C-Clamp complete set The Pelvic C-Clamp set consists of the instruments and implants for the emergency treatment of the indicated fracture types. The bottom layer of the Vario Case houses the Pelvic C-Clamp and the optional pliers. The upper layer houses the cannulated nails in two lengths and the remaining instruments. The complete sterile Pelvic C-Clamp set should be kept ready for use in the resuscitation room. Depending on the type of injury, the...
カタログの7ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 6 Surgical Technique Preparation of the Pelvic C-Clamp Open the lower side arms by depressing the buttons on the arms to prepare the Pelvic C-Clamp for use. (a) Note: Hold upper and lower arms with both hands and ensure that the lower arm is locked when fully extended. (a) Extend the upper bars by depressing the buttons on the upper rails while simultaneously pulling on the side arms. (b) Note: Maximal extension of the Pelvic C-Clamp is advantageous for easy and safe positioning. (b) With a light twist, place the cannulated nails...
カタログの8ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 7 2 Identifying nail insertion point Instrument 03.306.009 Guide Handle, for Kirschner Wire л 2.5 mm Make an incision at the intersection between the extension of the line of the femoral axis over the tip of the greater trochanter, and a vertical line from the anterior superior iliac spine in the dorsal direction (see illustration). If orientation is difficult, use an image intensifier. The surface reference point of the outer side of the ilium changes at the level of the sacroiliac joints. In emergency situations, the resulting...
カタログの9ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Surgical Technique 3 Kirschner Wire placement Instruments 03.306.009 Guide Handle, for Kirschner Wire л 2.5 mm 292.260 Kirschner Wire л 2.5 mm with trocar tip, length 280 mm 398.320 Socket Wrench л 11 mm with Hammer After having identified the insertion point, a Kirschner Wire can be placed through the Guide Handle (only on the uninjured side). Gently hammer the Kirschner Wire into the bone with the Socket Wrench with Hammer. This Kirschner Wire will ensure an exact placement of the cannulated nail and prevents the nail from slipping....
カタログの10ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 9 4 Placement of the Pelvic C-Clamp Instruments 03.306.010 Pelvic C-Clamp, complete 02.306.006 or 02.306.007 Nail for Pelvic C-Clamp, cannulated, short, length 190 mm (2) Nail for Pelvic C-Clamp, cannulated, long, length 210 mm (2) 321.200 Ratchet Wrench for Nut, hexagonal, 11 mm 391.930 Wire Cutter, large, with multiplication, length 220 mm Optional instruments 359.204 Pliers, flat nosed 395.781 Cap Be sure the fracture is correctly reduced before placement of the Pelvic C-Clamp. After inserting the Kirschner Wire on the...
カタログの11ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 10 Surgical Technique Alternative: Both nails can be placed at the same time. To do this take off one side arm. After both nails have been seated properly the arm can be placed over the rail again and compression can be achieved as described below. When both nails are correctly seated, manually compress the upper side arms (a) and ensure final fixation by tightening the threaded tubes with the Ratchet Wrench (b). The Kirschner wire must be cut off with the wire cutter or removed. If desired, place a protective cap on each end of...
カタログの12ページ目を開く0x6.000.899_AC.qxp:0x6.000.899_AC 10.12.2008 8:51 Uhr Seite 11 5 Postoperative management – AP plain radiograph, CT if required, rarely oblique view films after application of Pelvic C-Clamp and during follow-up. – Do not use the Pelvic C-Clamp to lift the patient. – Wound closure; extended incisions may require a coapting skin suture. – Continuing injury management according to polytrauma protocols. – The nail insertion sites must be meticulously disinfected and dressed. – Should the patient need to be moved, he/she should on no account be placed on his/her side as this could cause one of...
カタログの13ページ目を開くDepuy Synthesのすべてのカタログと技術パンフレット
-
Building on Success
16 ページ
-
RADIUS OF CURVATURE
3 ページ
-
HEALIX ADVANCE
4 ページ
-
3.5 mm LCP™ Medial
15 ページ
-
MatrixRIB®FixationSystem
86 ページ
カタログアーカイブ
-
2.4 mm VA LCP™
4 ページ
-
Power line II
4 ページ
-
Concorde
28 ページ
-
LCP Intercarpal
31 ページ
-
LCS® COMPLETE™
2 ページ
-
Synthes TPLO.
8 ページ
-
SynFix-LR System
56 ページ
-
CONDUIT™
15 ページ
-
Brochure_FINAL
2 ページ
-
DePuy Synthes
81 ページ
-
Anspach
3 ページ
-
PINNACLE® Hip Solutions
12 ページ
-
Corail
24 ページ
-
S-ROM® NOILES™
68 ページ
-
Speed
2 ページ
-
attune
80 ページ
-
HAMMERLOCK® 2
2 ページ
-
Polar
4 ページ
-
Alveolar Distractor.
4 ページ
-
Piezoelectric System
4 ページ
-
Air Power Line II
6 ページ
-
TruMatch Pin Guides
16 ページ
-
P F N A
8 ページ
-
SKILL, DEDICATION,
16 ページ
-
Orthopaedics. Overview
20 ページ
-
DURALOC
16 ページ
-
Marathon Cemented Cup
20 ページ
-
REEF Surgical Technique
16 ページ
-
MatrixNEURO
8 ページ
-
Anspach XMax
4 ページ
-
Anspach eMax 2 Plus
4 ページ
-
Small Electric Drive
4 ページ
-
Air Pen Drive
4 ページ
-
Colibri II
4 ページ
-
Spine
25 ページ
-
LCP Distal Fibula Plates
32 ページ
-
TomoFix
60 ページ
-
Expert Tibia Nail
84 ページ
-
Sacral Bars
16 ページ
-
LCP
24 ページ
-
PFNA
112 ページ
-
HCS 1.5, 2.4, 3.0
36 ページ
-
LCP Wrist Fusion
32 ページ
-
LCP Compact Hand
28 ページ
-
VA-LCP Elbow
48 ページ
-
Distal Radius
44 ページ
-
Olecranon
30 ページ
-
LCP Hook Plate
28 ページ
-
DHP & Olecranon
4 ページ
-
LCP S-A
4 ページ
-
Epoca
4 ページ
-
Philos
32 ページ
-
MultiLoc
68 ページ