Variable Angle LCP Dorsal Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. DePuy Synthes PART OF THE FAMILY OF COMPANIES
カタログの1ページ目を開くImage intensifier control This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, as well as processing guidelines for implants, please contact your local sales representative or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance For general information about reprocessing, care and maintenance of Synthes...
カタログの2ページ目を開くIntroduction Variable Angle LCP Dorsal Distal Radius Plate 2.4 2 Surgical Technique Recommendations on Screw and Plate Insertion 8 Screw Insertion Techniques 8 Screw Type Determination 9 Plate Insertion Technique 10 Postoperative Treatment / Implant Removal 25 Variable Angle LCP Dorsal Distal Radius Plate 2.4 Surgical Technique DePuy Synthes
カタログの3ページ目を開くVariable Angle LCP Dorsal Distal Radius Plate 2.4. For fragment-specific fracture fixation with variable angle locking technology. The low profile dorsal distal radius plates are intended for the double- plate technique. All implants are available in stainless steel and titanium. Variable angle locking Holes allow up to 15° off-axis screw a ngulation in all directions in order to a ddress the individual fracture patterns. Undercuts and bending notches Undercuts and bending notches a llow easy contouring of the plates while preserving the VA locking holes. Low profile construct...
カタログの4ページ目を開くAnatomical fit Anatomical pre-contoured plates for the radial and intermediate column minimize the need for bending. Oblong VA combi-hole Allows accurate plate positioning on the bone. Kirschner wire holes Enable preliminary plate fixation. Variable Angle LCP Dorsal Distal Radius Plate 2.4 Surgical Technique DePuy Synthes
カタログの5ページ目を開くIn 1958, the AO formulated four basic principles, which have In 1958, the guidelines for internalbasic principles, which AO formulated four fixation1,2. become have become the guidelines for internal xation1, 2. Anatomic reduction Anatomic Fracture reduction and xation Fracture reduction and fixation to to restore anatomical relationships. restore anatomical relationships. 1 Early, Early, active mobilization mobilization Early and Early and safe mobilization and mobilization and rehabilitation of the injured part and rehabilitation the injured part the the patient as a whole. and patient as...
カタログの6ページ目を開くIntended Use The plate and screw implants included in the Radius Plate product family are intended for temporary fixation, correction or stabilization in the radius anatomical region. Indications 2.4 mm Variable Angle LCP Dorsal Distal Radius Plates are indicated for: –– Dorsally displaced fractures –– Extra-articular and intra-articular fractures with metaphyseal defect –– Open joint reconstruction –– Combination of distal radius with carpal and metacarpal fractures –– Corrective osteotomies after distal radius malunion Variable Angle LCP Dorsal Distal Radius Plate 2.4 Surgical Techniqu
カタログの7ページ目を開くClinical Cases Case 1 69-year-old female with AO 23A2 fracture Preoperative, lateral view Postoperative, lateral view Preoperative, lateral view Postoperative, lateral view Case 2 59-year-old male with AO 23C2 fracture 6 DePuy Synthes Variable Angle LCP Dorsal Distal Radius Plate 2.4 Surgical T
カタログの8ページ目を開くThree-Column Theory The treatment of distal radius fractures requires a meticulous reconstruction of the joint surface, as well as stable internal fixation and early functional postoperative treatment. Extra-articular fractures require both the restoration of the volar tilt and radial length to reduce the possibility of displacement. Any malalignment may result in limitations of movement, changes of load distribution, mid-carpal instability as well as the increased risk of osteoarthritis in the radiocarpal joint. Intra-articular fractures with articular displacement of more than 2 mm in the...
カタログの9ページ目を開くRecommendations on Screw and Plate Insertion Screw Insertion Techniques Variable angle locking screws can be inserted using two different techniques: – Variable angle technique – Pre-defined nominal angle technique Funnel-shaped end for offaxis drilling Fixed-angle end for nominal angle drilling VA-LCP Drill Sleeve (03.110.000) VA-LCP Drill Sleeve, freehand (03.111.004), for off-axis drilling a) Variable angle technique To drill variable angle holes up to 15° deviation from the nominal trajectory of the locking hole, insert the tip of the VA-LCP drill sleeve and key into the cloverleaf...
カタログの10ページ目を開くRecommendations on Screw and Plate Insertion Screw Type Determination Determine whether standard cortex screws or variable angle locking screws will be used for fixation. The final screw placement and the use of VA locking and cortex screws are determined by the fracture pattern. If a VA locking screw is inserted first, ensure that the plate is held securely against the bone to prevent the plate from spinning as the screw locks into the plate. When using the pre-defined nominal angle technique s tandard locking screws can also be used instead of VA locking screws. VA locking hole: 2.4 mm...
カタログの11ページ目を開くRecommendations on Screw and Plate Insertion Plate Insertion Technique 1. Apply dorso-ulnar plate It is recommended to apply the dorso-ulnar plate first and fix it by inserting a 2.4 mm standard cortex screw in the o blong VA combi-hole in the proximal shaft. (See pages 16 –17 for insertion of cortex screws.) The plate supports the intermediate column and fixes the dorso-ulnar fragment. 2. Apply dorso-radial plate Apply the dorso-radial plate after provisional positioning of the dorso-ulnar plate by inserting a 2.4 mm standard cortex screw in the oblong VA combi-hole in the proximal...
カタログの12ページ目を開くDepuy Synthesのすべてのカタログと技術パンフレット
-
Building on Success
16 ページ
-
RADIUS OF CURVATURE
3 ページ
-
HEALIX ADVANCE
4 ページ
-
3.5 mm LCP™ Medial
15 ページ
-
MatrixRIB®FixationSystem
86 ページ
カタログアーカイブ
-
2.4 mm VA LCP™
4 ページ
-
Power line II
4 ページ
-
Concorde
28 ページ
-
LCP Intercarpal
31 ページ
-
LCS® COMPLETE™
2 ページ
-
Synthes TPLO.
8 ページ
-
SynFix-LR System
56 ページ
-
CONDUIT™
15 ページ
-
Brochure_FINAL
2 ページ
-
DePuy Synthes
81 ページ
-
Anspach
3 ページ
-
PINNACLE® Hip Solutions
12 ページ
-
Corail
24 ページ
-
S-ROM® NOILES™
68 ページ
-
Speed
2 ページ
-
attune
80 ページ
-
HAMMERLOCK® 2
2 ページ
-
Polar
4 ページ
-
Alveolar Distractor.
4 ページ
-
Piezoelectric System
4 ページ
-
Air Power Line II
6 ページ
-
TruMatch Pin Guides
16 ページ
-
P F N A
8 ページ
-
SKILL, DEDICATION,
16 ページ
-
Orthopaedics. Overview
20 ページ
-
DURALOC
16 ページ
-
Marathon Cemented Cup
20 ページ
-
REEF Surgical Technique
16 ページ
-
MatrixNEURO
8 ページ
-
Anspach XMax
4 ページ
-
Anspach eMax 2 Plus
4 ページ
-
Small Electric Drive
4 ページ
-
Air Pen Drive
4 ページ
-
Colibri II
4 ページ
-
Spine
25 ページ
-
LCP Distal Fibula Plates
32 ページ
-
TomoFix
60 ページ
-
Expert Tibia Nail
84 ページ
-
Sacral Bars
16 ページ
-
Pelvic C-Clamp
20 ページ
-
LCP
24 ページ
-
PFNA
112 ページ
-
HCS 1.5, 2.4, 3.0
36 ページ
-
LCP Wrist Fusion
32 ページ
-
LCP Compact Hand
28 ページ
-
VA-LCP Elbow
48 ページ
-
Distal Radius
44 ページ
-
Olecranon
30 ページ
-
LCP Hook Plate
28 ページ
-
DHP & Olecranon
4 ページ
-
LCP S-A
4 ページ
-
Epoca
4 ページ
-
Philos
32 ページ
-
MultiLoc
68 ページ