Set SL 1500
1 / 6ページ

{{requestButtons}}

カタログの抜粋

Set SL 1500 - 1

Electronic Bowie Dick Test and Security during Routine Checks ebro, a NOVA Analytics company I ^ ANALYTICS

カタログの1ページ目を開く
Set SL 1500 - 2

Routine Checks in the CSSD simply done … with Set SL 1500 The set contains: 1 x Bowie Dick logger EBI 15 1 x Interface IF 150 suitable for EBI 15 and EBI 10 1 x Antenna AL 111 1 x Software Winlog.med 1 x Alu carrying case Additionally required for routine checks of washer-disinfectors: 1 x Temperature logger EBI 10-T100 Description Type Starter-Kit SL 1500 1340-6195 Temperature logger EBI 10-T100 1340-6100 ebro® Electronic GmbH & Co. KG Peringerstraße 10 • D-85055 Ingolstadt Tel. +49 (0) 841 - 9 54 78-0 Fax +49 (0) 841 - 9 54 78-80 Internet: www.ebro.com E-Mail: info @ ebro.com Part No.

カタログの2ページ目を開く
Set SL 1500 - 3

More Security during Routine Checks of Steam Sterilizers ...

カタログの3ページ目を開く
Set SL 1500 - 4

… BY VERIFICATION OF STERILIZATION PARAMETERS Checks sterilization temperature and sterilization time at +134°C (273°F) for 3.5 minutes according to DIN EN 285 … BY MEANS OF DATA LOGGING Stores up to 100,000 measured values with measuring rate adjustable from 250 ms; graphic presentation of pressure / temperature / time response … VIA DATA RECORDING WITH SOFTWARE Winlog.med · Support at routine check preparation / planning as well as at programming, evaluation, calibration and report generation · Integrated help function provides fast problem presentation of various errors and offers...

カタログの4ページ目を開く
Set SL 1500 - 5

... BY MEANS OF EARLY-WARNING SYSTEM Early identification of possible failures in steam sterili- zer. Even smallest quantities of residual air (that do not yet lead to a failed Bowie Dick Test) are detected ... VIA BOWIE DICK TEST Definite result „passed/failed" at daily check of air evacuation test and steam penetration test according to ... WITH CALCULATION OF LETHALITY (F0) Monitors deviations between cycles by calculating total quantity of energy expended during sterilization process; this is expressed by F0 value Reasonable vacuum check for sterilizers without pressure display...

カタログの5ページ目を開く
Set SL 1500 - 6

Advantages at a glance: > Exact and independent measurement of sterilizer performance > Definite result «passed / failed» > 500 cycles > After service/calibration re-useable > Electronic data logging Technical Data Type EBI 15 Measuring range Temperature: 0°C ... +150°C (32°F ... 302°F) Pressure: 0 mbar ... 4000 mbar ±0.1°C (±0.2°F) ±15 mbar (±1.5 kPa) 0.025°C (0.045°F) 1 mbar (100 Pa) 0°C ... +150°C (32°F ... 302°F) Temp.: Pt 1000, Piezo-resistive pressure sensor 2 temperature, 1 pressure · endless mode · start / stop time · measurement upon start time · start immediately until memory full...