
グループ: Fortive
カタログの抜粋

BP Pump 2 NIBP Simulator and Tester Operators Manual PN 2196592 June 2007 © 2007 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies.
カタログの1ページ目を開く
Warranty and Product Support Fluke Biomedical warrants this instrument against defects in materials and workmanship for one year from the date of original purchase. During the warranty period, we will repair or at our option replace, at no charge, a product that proves to be defective, provided you return the product, shipping prepaid, to Fluke Biomedical. This warranty covers the original purchaser only and is not transferable. The warranty does not apply if the product has been damaged by accident or misuse or has been serviced or modified by anyone other than an authorized Fluke...
カタログの2ページ目を開く
Notices All Rights Reserved © Copyright 2007, Fluke Biomedical. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without the written permission of Fluke Biomedical. Copyright Release Fluke Biomedical agrees to a limited copyright release that allows you to reproduce manuals and other printed materials for use in service training programs and other technical publications. If you would like other reproductions or distributions, submit a written request to Fluke Biomedical. Unpacking and Inspection Follow...
カタログの3ページ目を開く
Return Procedure All items being returned (including all warranty-claim shipments) must be sent freight-prepaid to our factory location. When you return an instrument to Fluke Biomedical, we recommend using United Parcel Service, Federal Express, or Air Parcel Post. We also recommend that you insure your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost shipments or instruments that are received in damaged condition due to improper packaging or handling. Use the original carton and packaging material for shipment. If they are not available, we...
カタログの4ページ目を開く
Restrictions and Liabilities Information in this document is subject to change and does not represent a commitment by Fluke Biomedical. Changes made to the information in this document will be incorporated in new editions of the publication. No responsibility is assumed by Fluke Biomedical for the use or reliability of software or equipment that is not supplied by Fluke Biomedical, or by its affiliated dealers. Manufacturing Location The BP Pump 2 Non-invasive Blood Pressure Simulator and Tester is manufactured in Everett, Washington by Fluke Biomedical, 6920 Seaway Blvd., Everett, WA, U.S.A.
カタログの5ページ目を開く
BP Pump 2 Operators Manual
カタログの10ページ目を開く
BP Pump 2 Operators Manual
カタログの12ページ目を開く
BP Pump 2 Operators Manual
カタログの14ページ目を開く
Introduction and Specifications Introduction Introduction The Fluke Biomedical BP Pump 2 Non-Invasive Blood Pressure Simulator and Tester, hereafter known as the “Tester”, is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure Monitors (NIBPMs). The Tester provides dynamic blood pressure simulations, static calibration, automated leak testing, and pressure relief valve testing. The following models are available: • BP Pump 2L (Basic Model) BP Pump 2M (High-Accuracy Model) The Tester allows you to verify the performance claims of different blood pressure...
カタログの15ページ目を開く
BP Pump 2 Operators Manual Tester pressure accuracy can be improved by upgrading to a high-accuracy pressure transducer. This is a factory service upgrade and is provided to customers wanting to meet the DIN EN 1060 requirements for pressure measurement accuracy. For more information, refer to “Setup, Maintenance, and Support: Maintenance and Support.” General Safety Considerations This Tester complies with safety and technical requirements described in the following directives: • UL 3101-1, Electrical Equipment for Laboratory Use; Part 1: General Requirements. • CAN/CSA C22.2 No. 1010.1...
カタログの16ページ目を開く
Introduction and Specifications General Safety Considerations Warnings and Cautions Users are advised to read the manual carefully, observing all warnings and cautions, before attempting to set up and operate the Tester. A Warning identifies hazardous conditions and actions that could cause bodily harm or death. A Caution identifies conditions and actions that could damage the Tester or the equipment under test, or cause permanent loss of data. W X Warning To avoid possible electric shock or personal injury, follow these guidelines: • Read the Users Manual before operating the Tester. Use...
カタログの17ページ目を開く
BP Pump 2 Operators Manual Always connect the system power cord directly to a three-prong receptacle with a functional ground. Never use a two-prong plug adapter to connect primary power to the Tester, thereby disconnecting the utility ground. Disconnect the Tester from the power source before changing the supply voltage. The Tester operates at a range of 100 to 240 volts. W Caution To avoid damage to the Tester or adverse affects on its performance, follow these guidelines: • • Do not expose the system to temperature extremes. Ambient temperatures should remain between 15° C and 40° C....
カタログの18ページ目を開く
Introduction and Specifications Instrument Familiarity Instrument Familiarity Figure 1-1 shows the Tester. The top and side panel components are described in Table 1-2 and the number key functions are described in Table 1-3. Figure 1-1. Tester Top and Side Panel Components
カタログの19ページ目を開く
BP Pump 2 Operators Manual Table 1-2. Top and Side Panel Components Label Returns the operator to the Main Menu. Makes dynamic assignments based on the current screen. Number (Test and Simulations) Keys Allows the operator to perform auto sequences and simulations using numeric keys. Advances to the next menu or saves/selects options. Pulse Indicator LED blinks in synchronization with beeper, indicating that the pump is generating a simulated blood pressure pulse. Allows connection of optional ECG accessory (refer to Appendix, ECG Option). Printer Port Provides D-25 female connector for...
カタログの20ページ目を開く
Introduction and Specifications Instrument Familiarity Table 1-3. Number Key Functions Number PRESSURE LEAK Pressurizes a pneumatic system to an operator-defined target pressure up to 400 mmHg (53.3 kPa) and then measures the loss of pressure over time. PRESSURE RELIEF Increases the pressure in the pneumatic system until the relief valve on the NIBP monitor opens or until the Setpoint is reached, whichever occurs first. STATIC PRESSURE Accessed via the Pressure Gauge Test, which enables the Tester to measure static pressure generated by an external source in the range of 50 to 400 mmHg 6.7...
カタログの21ページ目を開くFluke Health Solutionsのすべてのカタログと技術パンフレット
-
ESA612
6 ページ
-
PS320
5 ページ
-
Impulse 6000D/7000DP
15 ページ
-
190M
8 ページ
-
ESA615
7 ページ
-
Gas flow analyzer
2 ページ
-
ProSim 3 and 2
7 ページ
-
Product catalog
40 ページ
-
IDA-6 Flyer
1 ページ
-
ProSim SPOT Light
4 ページ
-
VT900A Datasheet
6 ページ
-
VT900A + VAPOR
7 ページ
-
ESA614 Datasheet
6 ページ
-
451B
3 ページ
-
451P
3 ページ
-
ProSim 4
6 ページ
カタログアーカイブ
-
QA-ES Series II
4 ページ
-
RAYSAFE 452
9 ページ
-
RaySafe Dose Viewer
10 ページ
-
RaySafe DXR+
2 ページ
-
RaySafe Solo
5 ページ
-
DPM1B
2 ページ
-
SigmaPace™ 1000
8 ページ
-
965 Stack Monitor
3 ページ
-
INCU ?
4 ページ
-
76-606DX
2 ページ
-
07-CRXW and 07-QRX
4 ページ
-
RaySafe Xi
8 ページ
-
RaySafe X2
12 ページ
-
VT305
4 ページ
-
ProSim
8 ページ